Furuno FI-504 manual Specifications

Page 37

 

 

FI-504 MULTI

 

SPECIFICATIONS OF

 

FI-504 MULTI

1

GENERAL

 

1.1

Display

Segment LCD

1.2

Display Content

Depth, speed, wind speed, wind angle,

 

 

timer, environmental information (water

 

 

temperature, air temperature, air

 

 

pressure, dewpoint, wind chill

 

 

temperature), rudder angle

1.3

I/O Port

NMEA 2000, 2 ports

2

JUNCTION BOX (OPTION)

 

2.1

No. of I/O ports

 

 

NMEA 2000 Device

6 ports

 

NMEA 2000 Backbone

2 ports

3 POWER SUPPLY AND POWER CONSUMPTION

3.1

Display Unit

12 VDC, less than 0.1 A

3.2

Junction Box

12 VDC, less than 1 A, max. 2A connectable

4

ENVIRONMENTAL CONDITIONS

4.1

Useable Temperature Range

-15°C - +55°C

4.2

Relative Humidity

Less than 95% (+40°C)

4.3

Waterproofing

 

 

Display Unit

IP56

 

Junction Box

IPX0

4.4

Vibration

- 2 Hz-5 Hz and up to 13.2 Hz with an

 

 

excursion of ±1 mm ±10% (7 m/s2

 

 

maximum acceleration at 13.2 Hz);

 

 

- above 13.2 Hz and up to 100 Hz with a

 

 

constant maximum acceleration of 7 m/s2

5

COATING COLOR

 

5.1

Display Unit

N2.5

5.2

Junction Box

N2.5

SP-1

E7269S01A

Image 37
Contents FI-504 Multi Instrument 00016733410 Important Notices Safety Instructions Table of Contents Word to the Owner of the FI-504 ForewordStandalone configuration System ConfigurationNmea 2000 Sensors Nmea 2000 networkOperating Controls, Display Layout OperationAdjusting Brilliance and Contrast Turning the Power On/OffDepth Selecting a DisplayDepth category Display descriptionSpeed category Wind category Timer categoryNavigation category Heading categoryAutopilot category Environment categoryEngine category Selecting Apparent or True Wind Angle, Wind Speed Resetting Counters and IndicationsMAX38.9 LO9.7 12.2 AlarmsAlarm description Count-up timer TimersCount-down timers How to set the timersOperation Preventive Maintenance MAINTENANCE, TroubleshootingTroubleshooting Equipment Lists InstallationStandard supply Optional supplySurface mount 1 Fix instrument from front panel MountingSurface mount 2 Fix instrument from rear panel Multi-instrument configuration WiringJunction box option Sensor FI-50x FI-50x FI-50x Terminal resistorSetup1 menu Setting UpOff OFF SPD RES LOC OFF Setup2 menuSetup2 menu items Press the SELECT/CLEAR Specifications Packing フラッシュマウントキット Jul.2407 R.Esumi Jul.2407 R.Esumi Jul.2407 R.Esumi Instrument タッピンネジ用穴(4ヵ所) For tapping screws 4 pcs