Furuno FI-504 manual Setting Up, Setup1 menu

Page 29

3. INSTALLATION

Turn on the terminal resistor in the junction box when the NMEA 2000 sensor(s) connected to it do not have a terminal resistor.

Terminal Resistor

OFF:

ON:

For how to turn on the terminal resistor in a FI-50 series instrument, see page 33 (FI-501//FI-502/FI-505) or page 35 (FI-506).

3.4Setting Up

Your instrument is pre-programmed with factory default settings, which may or may not be suited to your vessel. Therefore, it is necessary to ini- tialize the instrument for use with your vessel. This should be done im- mediately after completion of the installation.

Two sets of setup menus are provided: setup1 and setup2. The setup1 menu provides system parameters and the setup2 menu has user set- tings.

3.4.1Setup1 menu

The setup1 menu contains system parameters which optimize the instru- ment for use on your vessel. Follow the procedure below to access and set parameters.

1.Press the APP/TRUE and SELECT/CLEAR keys momentarily to enable the setup1 menu. The Depth unit selection screen appears, with the depth unit flashing. (See the illustration on the next page.)

2.Use the DISP key to select a menu item. Each press of the key changes the menu item in the sequence shown in the illustration on the next page.

21

Image 29
Contents FI-504 Multi Instrument 00016733410 Important Notices Safety Instructions Table of Contents Word to the Owner of the FI-504 ForewordStandalone configuration System ConfigurationNmea 2000 Sensors Nmea 2000 networkOperating Controls, Display Layout OperationAdjusting Brilliance and Contrast Turning the Power On/OffDepth Selecting a DisplaySpeed category Display descriptionDepth category Wind category Timer categoryNavigation category Heading categoryEngine category Environment categoryAutopilot category Selecting Apparent or True Wind Angle, Wind Speed Resetting Counters and IndicationsMAX38.9 LO9.7 12.2 AlarmsAlarm description Count-up timer TimersCount-down timers How to set the timersOperation Preventive Maintenance MAINTENANCE, TroubleshootingTroubleshooting Equipment Lists InstallationStandard supply Optional supplySurface mount 1 Fix instrument from front panel MountingSurface mount 2 Fix instrument from rear panel Multi-instrument configuration WiringJunction box option Sensor FI-50x FI-50x FI-50x Terminal resistorSetup1 menu Setting UpOff OFF SPD RES LOC OFF Setup2 menuSetup2 menu items Press the SELECT/CLEAR Specifications Packing フラッシュマウントキット Jul.2407 R.Esumi Jul.2407 R.Esumi Jul.2407 R.Esumi Instrument タッピンネジ用穴(4ヵ所) For tapping screws 4 pcs