The setup 2 menu contains user settings which once preset do not re- quire frequent adjustment.

1.Press and hold down the APP/TRUE and SELECT/CLEAR keys together (about 5-6 seconds) to enable the user settings menu. The software version of CPU1 appears. (See the illustration below.)

2.Press the DISP key to choose menu item. Each press of the key changes the menu item in the sequence shown below.

*XXxx=program and program ver. nos.

XXxxx*

XXxxx*

KEYBEEP

A

BRILL

ALT

 

 

CAL

 

CAL

CAL

 

 

ON

 

ON

OFF

Program ver. Program ver.

Key

 

Auto

Alternating

no. (CPU1)

no. (CPU2)

beep

brilliance

displays

SETUP

rES

SYNCHRO

DEPTH

SPEED

CAL

CAL

CAL

 

CAL

CAL

ON

OFF

ON

 

ON

ON

Setup 1 menu

Terminal

Synchronization

Depth

Speed

 

resistor

 

displays

displays

TIMER

WIND

HEADING

NAVI

ENVIRO

CAL

CAL

CAL

 

CAL

CAL

ON

ON

ON

 

ON

ON

Timer

Wind

Heading

 

Nav

Environment

displays

displays

displays

displays

displays

A PILOT

ENGINE

DEMO

RESET

 

CAL

CAL

CAL

 

CAL

 

ON

ON

OFF

 

OFF

 

Autopilot

Engine

Demo

Restore factory

 

displays

displays

mode

defaults

 

3.Use the SELECT/CLEAR key to select setting.

4.To continue, press the DISP key to select another item.

5.To save settings and restore normal operation, press the APP/TRUE and SELECT/CLEAR keys together.

26

Image 34
Contents FI-504 Multi Instrument 00016733410 Important Notices Safety Instructions Table of Contents Foreword Word to the Owner of the FI-504System Configuration Standalone configurationNmea 2000 network Nmea 2000 SensorsOperation Operating Controls, Display LayoutTurning the Power On/Off Adjusting Brilliance and ContrastSelecting a Display DepthDepth category Display descriptionSpeed category Timer category Wind categoryHeading category Navigation categoryAutopilot category Environment categoryEngine category Resetting Counters and Indications Selecting Apparent or True Wind Angle, Wind SpeedAlarms MAX38.9 LO9.7 12.2Alarm description Count-down timers TimersCount-up timer How to set the timersOperation MAINTENANCE, Troubleshooting Preventive MaintenanceTroubleshooting Standard supply InstallationEquipment Lists Optional supplyMounting Surface mount 1 Fix instrument from front panelSurface mount 2 Fix instrument from rear panel Wiring Multi-instrument configurationJunction box option Terminal resistor Sensor FI-50x FI-50x FI-50xSetting Up Setup1 menuOff OFF SPD RES LOC Setup2 menu OFFSetup2 menu items Press the SELECT/CLEAR Specifications Packing フラッシュマウントキット Jul.2407 R.Esumi Jul.2407 R.Esumi Jul.2407 R.Esumi Instrument タッピンネジ用穴(4ヵ所) For tapping screws 4 pcs