Precautions When Working With Batteries

WARNING: Explosion or fire hazard

1.Follow all instructions published by the battery manufacturer and the manufacturer of the equipment in which the battery is installed.

2.Make sure the area around the battery is well ventilated.

3.Never smoke or allow a spark or flame near the engine or batteries.

4.Use caution to reduce the risk of dropping a metal tool on the battery. It could spark or short circuit the battery or other electrical parts and could cause an explosion.

5.Remove all metal items, like rings, bracelets, and watches when working with lead-acid batteries. Lead-acid batteries produce a short circuit current high enough to weld metal to skin, causing a severe burn.

6.Have someone within range of your voice or close enough to come to your aid when you work near a lead-acid battery.

7.Have plenty of fresh water and soap nearby in case battery acid contacts skin, clothing, or eyes.

8.Wear complete eye protection and clothing protection. Avoid touching your eyes while working near batteries.

9.If battery acid contacts skin or clothing, wash immediately with soap and water. If acid enters your eye, immediately flood it with running cold water for at least twenty minutes and get medical attention immediately.

10.If you need to remove a battery, always remove the ground terminal from the battery first. Make sure all accessories are off so you don’t cause a spark.

975-0263-01-01

vii

Image 8
Contents Xantrex PRO Inverter XM 1000 and XM Xantrex PRO Inverter Owner’s GuideDate and Revision About This Guide PurposeScope AudienceConventions Used Related InformationImportant Safety Instructions Explosive Gas Precautions SafetyPrecautions When Working With Batteries Precautions for Using Rechargeable Appliances Contents Troubleshooting OperationAlternators and Charging Systems SpecificationsBattery Types Xii Quality Power IntroductionLow battery voltage shutdown Shuts the XM 1800 down Comprehensive ProtectionFeatures Materials ListFront Panel Side ViewRear Panel Page Installation Designing Your Installation1DC Input Configuration for Normal Loads 2DC Input Configuration for Heavy Loads Choosing an Effective Charging System Installation CodesCalculating Battery Requirements XM 1800 must only be installed in a location that is Choosing an Appropriate LocationCalculating Cable Sizes Calculating Size of DC Input CablesSizing the Chassis Ground Cable Calculating Fuse/Circuit Breaker Size To select the correct fuse type and sizeInstallation Tools and Materials Installing the XMSafety Instructions Installation To mount the XM Overview of Installation StepsMounting the Inverter Connecting the Chassis Ground Grounding LocationsChassis Ground Stud To connect the cable to the chassis ground studAC Wiring 3Required AC wire size vs. required breaker ratingConnecting AC Input 5XM 1800 AC Wiring Compartment Connecting AC Output to an Existing AC Circuit Make ModelTo make a permanent connection to existing AC wiring AC Wiring 6AC Wiring Diagram with an Inverter Subpanel 7AC Wiring Diagram without an Inverter Subpanel Connecting the DC Cables To connect the DC cablesConnecting the DC Cables To test the XM 1800 in invert mode Testing Your InstallationTesting in Invert Mode Testing in Shore Power Mode To test the XM 1800 in shore power modeInstalling the Remote Panel To install the remote panel in another locationInstalling the Remote Panel Page Operation Feature Front Panel OperationTurning the Inverter On and Off Operating in Shore Power ModeOperating in Inverter Mode Checking Battery Status Checking Output PowerTurning the Inverter Off When Not Used Operating Several Loads at OnceInput Voltage Power OutputOperating Limits Inverter Loads Overload ConditionsHigh Surge Loads Trouble LoadsOver-temperature Conditions Routine MaintenanceXM 1800 Unit BatteriesPage Troubleshooting Common Problems Understanding Fault CodesBuzz in Audio Equipment Television Reception1Fault Codes Troubleshooting Reference Troubleshooting ReferenceTroubleshooting Reference Page Specifications Electrical PerformancePhysical Specifications Mounting Dimensions Figure A-1XM 1800 Mounting DimensionsFigure A-2XM 1000 Mounting Dimensions Automotive Starting Batteries Battery TypesBattery Types Battery Size Deep-Cycle BatteriesBattery Size To determine how much battery capacity you need Estimating Battery RequirementsBattery Sizing Example Battery Sizing Worksheet Two Batteries Connected In Parallel Using Multiple BatteriesTwo Separate Battery Banks Battery Tips Following table Alternators and Charging Systems Charging System RequirementsUsing a Standard Vehicle Alternator Using a Multi-stage Alternator RegulatorUsing a High-Output Alternator Charging With an Engine AlternatorCharging From AC Power Charging From Alternative Energy SourcesPage Warranty and Return Information WarrantyExclusions DisclaimerProduct Return Material Authorization Policy Return ProcedureOut of Warranty Service Information About Your System