Understanding Fault Codes
Table 5-1 Fault Codes
Fault | Status |
|
|
Code | LED | Description | Solution |
|
|
|
|
E01 | Yellow | Check the connections and cable to see if the battery is fully | |
|
| warning | charged. Recharge the battery if it is low. |
|
|
| Reduce the load. |
|
|
|
|
E02 | Red | Disconnect the load and recharge the battery. | |
|
| shutdown |
|
|
|
|
|
E03 | Red | Make sure the XM 1800 is connected to a 12 V battery. | |
|
| shutdown |
|
|
|
|
|
E04 | Yellow | Overload shutdown | Make sure the load does not exceed the XM 1800’s output |
|
| warning | rating. Reduce the load if necessary. |
|
|
|
|
E05 | Red | Overload shutdown | Reduce or disconnect the load. Make sure the load does not |
|
|
| exceed the XM 1800’s output rating. |
|
| Short circuit | Check connection to the load. |
|
|
|
|
E06 |
| Not used |
|
|
|
|
|
E07 | Yellow | Allow the unit to cool off. Reduce the load if continuous | |
|
| shutdown warning | operation is required. |
|
|
| Improve ventilation. Make sure the inverter’s ventilation |
|
|
| openings are not obstructed. |
|
|
| Reduce the ambient temperature. |
|
|
|
|
E08 | Red | Allow the unit to cool off. | |
|
| shutdown | Improve ventilation. Make sure the inverter’s ventilation |
|
|
| openings are not obstructed. |
|
|
|
|
Important: In order to reset the unit after an error has occurred, you have to remove shorepower (i.e., AC input), turn the unit off, then turn back on again.