Series 830/840/860 Instruction Manual

Chapter 2 Installation

 

 

Chapter 2 Installation

Quick-Installation Instructions For

830/840 L, M and H Meters And Controllers

1.NEVER TEST FOR LEAKS WITH LIQUID LEAK DETECTOR. If liquid seeps into the electronics or the sensor compartment below, the instrument may be damaged. Use a pressure-decay test in- stead.

2.Install an appropriate in-line filter upstream if the gas contains any particulate matter or condensed moisture. (A 15-micron par- ticulate filter for full-scale flows up to 30 liters/minute is recom- mended, 30 micron for flows above 30).

3.Mount with a horizontal gas-flow. This orientation is preferable unless the factory calibration was specifically performed for a ver- tical flow. Consult your calibration certificate. (Horizontal flow is assumed unless vertical flow upward or downward is specified).

4.DO NOT APPLY POWER TO THE OUTPUT LOOP on units equipped and calibrated for a 4-20 mA output signal. This is NOT a loop-powered device. Damage will occur.

5.Wire the instrument per the diagrams on the back of this card or the Operator’s Manual, Chapter 2. Controllers require a separate ground wire for the Valve Return signal as well as a Setpoint sig- nal (no wire connected to the setpoint may cause the valve to float open).

6.Apply the gas listed on the label to the inlet at the recommended inlet pressure as listed on the calibration certificate. On a meter, obtain this pressure by blocking off the flow downstream. On a controller, confirm that there is no gas flowing through it with a zero setpoint. (If there is a flow, consult the Valve Adjustment Procedure in the manual).

7.Apply power and verify or adjust the zero setting after allowing a 15-minutewarm-up period. The zero adjustment potentiometer is accessed through the upper hole in the side of the electronics cover. (See the Operator’s Manual, Chapter 3).

8.DO NOT LEAVE A SETPOINT APPLIED TO A CONTROLLER WHEN NO GAS IS AVAILABLE TO THE INLET FITTING. The control circuit will apply the maximum voltage to the valve coil re- sulting in eventual overheating. Damage may occur. (Instead, consult the Operator’s Manual for use of the “Valve Off” feature).

9.An ANNUAL factory evaluation and calibration is recom- mended.

Email Technical Support: Service@sierrainstruments.com

Website Self Service: www.sierrainstruments.com

IM-83/84/86-H

2-1

Image 13
Contents Table of Contents Customer Notice Table of Contents Table of Contents Troubleshooting List of Tables Table of Contents Introduction Using This ManualIntroduction Receipt of System Components Safety InformationTechnical Assistance Flow Paths through the Transducer Series 800 Flow Sensing PrincipleSensor Temperature Distribution Installation Installation Overview Compression Fittings Installing the TransducerVCO Fittings NPT Fittings and 1/2-Inch Connections All Types VCR FittingsRecommended Wire Gauges Wiring the TransducerRecommended Wire Gauges Output Signal Connections Wiring Transducers with 20-Pin Card-Edge Connectors InputInput Signal Connections Controllers Only Depending on the valve voltage, connect as shown below Valve Purge and Valve Off Connections Controllers OnlyPin Connector Pin Designations Input Power Connections Wiring Transducers with 15-Pin D-ConnectorsInput Signal Connections Controllers Only 13. Valve Purge and Valve Off 15-Pin D-Connector 15 -Pin D-Connector Pin Assignments 16. Motor-Operated Rotary Valve Connector 10-Pin Connector Motor-Operated Valve Circular 10-Pin ConnectorMass Flow Meter Operation OperationElectromagnetic Valve Controllers Mass Flow Controller OperationMotor-Operated Rotary Valve Controllers Controller Auto Shut-Off Feature Mass Flow Controller FeaturesOver-Range and Cold Sensor Lockout Circuit Soft Start Response Times On-Off Control and Soft Start OptionPurging Non-Reactive Gases Valve Purge FunctionPurging Reactive Gases Operation Cleaning the Laminar Flow Element Flow Path MaintenanceLow Flow Transducers Low Flow Transducer LFE CleaningMedium Flow Transducers Medium Flow Transducer LFE CleaningHigh Flow Transducers High Flow Transducer LFE CleaningNPT-Type Transducers NPT Transducer LFE CleaningSensor Cleaning and Inspection Sensor MaintenanceSensor Electrical Test Electromagnetic Valves Low and Medium Flow Controllers Valve MaintenanceElectromagnetic Valves High Flow Controllers Maintenance Motor-Operated Rotary Valves 840 L, M and H series Valve Adjustment Procedure Maintenance Maintenance Transducer Calibration Troubleshooting Flow Meters and Flow Controllers with Electromagnetic Valves Valve rotates continuously Flow Controllers with Motor-operated Rotary ValvesFactory Calibration-All Models Instructions for Returning Your Instrument for ServiceReturn Address Example 1 Changing Standard Conditions Conversion of Flow Rate to Other T and P ConditionsExample 2 Finding the Actual Flow Rate 14.7 460 + 10.00 = 3.47 lm 14.7 + Calculating For a Single Gas 880 Example Important Note about K-FACTORS Calculating Dual Gas MixturesNEO Gas Tables and K-factorsC2H6O CH 3SH Operating Specifications Appendix B Product SpecificationsVDC Physical Specifications Performance SpecificationsValve plug standard Neoprene, 4079 Kal-Rez Low Flow Body Transducer Mounting DimensionsMedium Flow Body High Flow Body Appendix B Specifications IM-83/84/86-H Flow Range, slpm NPT Flow Body100 200 Inlet Fnpt Appendix B Specifications

840, 830, 860 specifications

The Sierra 860, 830, and 840 are a series of rugged outdoor laptops designed for professionals who require reliable and powerful computing solutions in challenging environments. These laptops combine advanced technologies and robust construction to meet the demands of various fields, including engineering, military, field services, and outdoor research.

One of the standout features of the Sierra series is its rugged design. Constructed with military-grade materials, these laptops are highly resistant to shock, vibration, and extreme temperatures. They have undergone rigorous testing according to MIL-STD-810G standards, which ensures they can withstand harsh conditions whether in the field or during transport. Additionally, the IP65 rating guarantees protection against dust and water exposure, making them invaluable for professionals working in inclement weather or dusty environments.

The Sierra 860, 830, and 840 are powered by high-performance processors, delivering fast and efficient processing capabilities. Equipped with the latest Intel Core processors, including i5 and i7 options, these laptops can handle demanding applications and multitasking with ease. The robust memory options, ranging from 8GB to 32GB, ensure smooth performance for memory-intensive tasks.

Display quality is another critical aspect of these laptops. The Sierra series features high-resolution screens that offer bright, vivid colors and sharp details, making them ideal for tasks requiring precision, such as drafting and design work. The touch-enabled displays enhance user interaction, providing convenience in outdoor settings where traditional input methods may be challenging.

The Sierra laptops also include a comprehensive array of connectivity options, ensuring seamless integration with various devices. With multiple USB ports, HDMI output, and optional mobile broadband, users can easily connect to peripherals, transfer data, and maintain communication. The inclusion of enterprise-level security features, including biometric scanners and encrypted storage, ensures sensitive data remains protected.

Battery life is another crucial factor in fieldwork, and the Sierra series excels in this area. With long-lasting batteries, these laptops can operate for extended periods without needing a recharge, making them perfect for long outdoor excursions or remote job sites.

In summary, the Sierra 860, 830, and 840 combine ruggedness, high performance, and extensive connectivity options, making them exceptional computing solutions for professionals in various challenging environments. Their advanced technologies and robust constructions ensure they can tackle the demands of outdoor work while maintaining reliability and efficiency.