Operation
15.Check A and B fluid pressure gauges (GA, GB) to ensure proper pressure balance between A and B. If imbalanced, bleed off the high side with valves SA and SB until balanced.
GA
GB
ti8442a
16. Open gun fluid manifold valves A and B.
The Fusion AP gun is shown.
ti2414A
17. Disengage gun piston safety lock.
ti2410A
18.Test spray onto cardboard.
19.Equipment is ready to spray.
3A1569B | 29 |