Graco A-25 important safety instructions Spraying, Closed

Page 24

Spraying

Spraying

The Fusion AP gun is shown.

1.After reaching spray temperatures, engage gun piston safety lock.

ti2409a

2. Close gun fluid inlet valves A and B.

5. Open air inlet ball valve (DD).

DDti17573a

6.Turn the air regulator counterclockwise to 0 pressure.

ti2728a

3.Attach gun fluid manifold. Connect gun air line. Open air line valve.

air

air motor

shutoff

regulator

valve

DD

ti17574a

7.Open the air motor shutoff valve.

8.Close the park valve.

ti2543a

4. Set PRESSURE RELIEF/SPRAY valves (SA, SB) to

SPRAY.

SA

Closed

SB

ti8442a

24

3A1569B

Image 24
Contents Operation Contents Proportioner Models SystemsRelated Manuals Proportioner Heated Hose GunElectric Shock Hazard Fire and Explosion Hazard Equipment Misuse Hazard Important Two-Component Material Information Changing Materials Typical Installation, without Circulation Typical Installation, without Circulation Key for FIGTypical Installation, with Circulation Typical Installation, with CirculationIG Typical Installation Component IdentificationMain Air Filter Filters system air supply Temperature Controls and Indicators See Tempera- ture Controls and IndicatorsControl Panel Main Power Switch Size ComponentSetup Determine Power SourceLocate Reactor A-25 Electrical Requirements Configure to Supply Power Step One Connect Electrical CordWatts Heater JumpersTerminal Blocks Iso Pump Lubrication System Setup Ground System Fluid Supply ConnectionsAir Supply Connection Install Fluid Temperature Sensor FTS Recirculation / Pressure Relief LinesConnect Heated Hose Fusion AP Gun shown Initial Startup Load Fluid with Feed Pumps Pressure Check Hose Set Temperatures Manual current control mode onlySupply Wet-Cups with Throat Seal Liquid Spraying ClosedSpray Adjustments SB SAPressure Relief Procedure ParkShutdown Open CloseFlushing Daily Start-up Procedure OperationOpen gun fluid manifold valves a and B Fluid Circulation Circulation Through ReactorCirculation Through Gun Manifold Circulation Kit CK Part Gun ManualDataTrak Controls and Indicators Run ModeSetup Mode Setup Mode Run ModeSee DataTrak Diagnostic Codes DataTrak OperationMaintenance Diagnostic Codes Temperature Control Diagnostic CodesDataTrak Diagnostic Codes Symbol Code Code Name Diagnosis CauseDimensions With Wheels Without Wheels Dimension In. mmTechnical Data Category DataGraco Standard Warranty Graco Information
Related manuals
Manual 56 pages 23.25 Kb