Graco A-25 Initial Startup, Load Fluid with Feed Pumps, Pressure Check Hose

Page 21

Initial Startup

Do not operate Reactor without all covers and shrouds in place.

Load Fluid with Feed Pumps

NOTE: The Reactor is tested with oil at the factory. Flush out the oil with a compatible solvent before spray- ing; see page 27.

1.Check that Setup process is complete; see page 15.

2.Turn on component B agitator, if used.

3.Turn both PRESSURE RELIEF/SPRAY valves (SA, SB) to SPRAY.

SB

SA

ti8442a

4. Open both fluid valves (FV).

FV ti17571a

5.Start feed pumps. Do not start proportioner air motor or pumps.

Always provide two grounded waste containers to keep component A and component B fluids separate.

Initial Startup

6.Purge air from hoses.

a.For Probler P2 guns: Loosen hose fittings and bleed out air until air-free fluid comes from hoses.

b.For Fusion guns: Hold gun fluid manifold over two grounded waste containers. Open fluid valves A and B until clean, air-free fluid comes from valves. Close valves.

The Fusion AP Gun is shown.

TI2484a

Pressure Check Hose

See hose manual. Pressure check for leaks. If no leaks, wrap hose and electrical connections to protect from damage.

3A1569B

21

Image 21
Contents Operation Contents Systems Proportioner ModelsRelated Manuals Proportioner Heated Hose GunElectric Shock Hazard Fire and Explosion Hazard Equipment Misuse Hazard Important Two-Component Material Information Changing Materials Typical Installation, without Circulation Key for FIG Typical Installation, without CirculationTypical Installation, with Circulation Typical Installation, with CirculationComponent Identification IG Typical InstallationMain Air Filter Filters system air supply Temperature Controls and Indicators See Tempera- ture Controls and IndicatorsControl Panel Size Component Main Power SwitchSetup Determine Power SourceLocate Reactor A-25 Electrical Requirements Step One Connect Electrical Cord Configure to Supply PowerWatts Heater JumpersTerminal Blocks Iso Pump Lubrication System Setup Ground System Fluid Supply ConnectionsAir Supply Connection Install Fluid Temperature Sensor FTS Recirculation / Pressure Relief LinesConnect Heated Hose Fusion AP Gun shown Initial Startup Load Fluid with Feed PumpsPressure Check Hose Manual current control mode only Set TemperaturesSupply Wet-Cups with Throat Seal Liquid Closed SprayingSB SA Spray AdjustmentsPark Pressure Relief ProcedureShutdown Open CloseFlushing Operation Daily Start-up ProcedureOpen gun fluid manifold valves a and B Circulation Through Reactor Fluid CirculationCirculation Kit CK Part Gun Manual Circulation Through Gun ManifoldDataTrak Controls and Indicators Run ModeSetup Mode Run Mode Setup ModeSee DataTrak Diagnostic Codes DataTrak OperationMaintenance Temperature Control Diagnostic Codes Diagnostic CodesDataTrak Diagnostic Codes Symbol Code Code Name Diagnosis CauseWith Wheels Without Wheels Dimension In. mm DimensionsCategory Data Technical DataGraco Information Graco Standard Warranty