Graco A-25 Configure to Supply Power, Step One Connect Electrical Cord

Page 16

Setup

Configure to Supply Power

NOTE: Both cord connection AND jumper positioning steps on page 17 must be completed.

Step One - Connect Electrical Cord

NOTE: Disregard terminal numbers on disconnect switch blocks. Wire to positions shown. Terminals will

accept up to #8 AWG (10 mm2) conductors.

1.Using a flat screw driver, turn cover fasteners 90° counterclockwise. Lift and pull the front cover away.

2.Connect main power cord to electrical console as follows:

a.Feed power cord through strain relief (SR) on right side of unit. Push black die release lever (RL) down to release contacts block (PD) for easy wiring.

NOTE: Strain relief accepts cords 0.59 to 1.0 in. (15-25

mm)diameter.

b.Connect power leads to Power Disconnect Switch (PD). Snap contacts block (PD) back onto switch.

c.Tighten strain relief nut.

d.Connect ground wire to ground lug (GL).

RL

PD

GL

SR

ti17570a

3.Replace lower front shroud. Reinstall the two screws retained in Step 1.

230V, 1 Phase: Use a screwdriver to connect two power leads to the top two middle terminal positions as shown. Connect green to ground (GND). See page 17 for proper jumper positions.

NOTE: Disregard terminal numbers on disconnect switch blocks. Wire to positions shown.

230V, 3 Phase Delta: Use a screwdriver to connect three power leads to top three left terminals as shown. Connect green to ground (GND). See page 17 for proper jumper positions.

380V, 3 Phase WYE: Use a screwdriver to connect four power leads to the top terminals as shown. Connect neutral only to N. Connect green to ground (GND). See page 17 for proper jumper positions.

16

3A1569B

Image 16
Contents Operation Contents Proportioner Models SystemsRelated Manuals Proportioner Heated Hose GunElectric Shock Hazard Fire and Explosion Hazard Equipment Misuse Hazard Important Two-Component Material Information Changing Materials Typical Installation, without Circulation Typical Installation, without Circulation Key for FIGTypical Installation, with Circulation Typical Installation, with CirculationIG Typical Installation Component IdentificationMain Air Filter Filters system air supply See Tempera- ture Controls and Indicators Temperature Controls and Indicators Control Panel Main Power Switch Size ComponentDetermine Power Source SetupLocate Reactor A-25 Electrical Requirements Configure to Supply Power Step One Connect Electrical CordHeater Jumpers WattsTerminal Blocks Ground System Fluid Supply Connections Iso Pump Lubrication System SetupAir Supply Connection Recirculation / Pressure Relief Lines Install Fluid Temperature Sensor FTSConnect Heated Hose Fusion AP Gun shown Load Fluid with Feed Pumps Initial StartupPressure Check Hose Set Temperatures Manual current control mode onlySupply Wet-Cups with Throat Seal Liquid Spraying ClosedSpray Adjustments SB SAPressure Relief Procedure ParkShutdown Open CloseFlushing Daily Start-up Procedure OperationOpen gun fluid manifold valves a and B Fluid Circulation Circulation Through ReactorCirculation Through Gun Manifold Circulation Kit CK Part Gun ManualRun Mode DataTrak Controls and IndicatorsSetup Mode Setup Mode Run ModeSee DataTrak Diagnostic Codes DataTrak OperationMaintenance Diagnostic Codes Temperature Control Diagnostic CodesDataTrak Diagnostic Codes Symbol Code Code Name Diagnosis CauseDimensions With Wheels Without Wheels Dimension In. mmTechnical Data Category DataGraco Standard Warranty Graco Information
Related manuals