Graco A-25 important safety instructions Maintenance

Page 34

Maintenance

Maintenance

Check and add TSL to B side pump wet-cup daily.

Check ISO lube bottle for significant discoloration or crystallization daily. Replace with fresh TSL when needed.

Ensure ISO (A) pump is down and in PARK position during every shutdown.

Keep any ISO (A) fluid from being exposed to atmo- sphere to prevent crystallization.

Remove inlet filter screen plug (V, Y) and clean screens if increased unbalanced pressures between A and B is noticed or as needed for fluids used. Also clean after flushing.

Close gun fluid shutoff valves when not in use.

If using a Fusion AP or Probler P2 gun, add grease with grease gun per manual.

Clean gun filter screens and mix chamber ports reg- ularly, or when increased unbalanced pressures between A and B is noticed. See gun manual.

Use lithium grease or Iso Pump Oil on all threaded fluid fittings on the “A” side.

34

3A1569B

Image 34
Contents Operation Contents Related Manuals Proportioner ModelsSystems Proportioner Heated Hose GunElectric Shock Hazard Fire and Explosion Hazard Equipment Misuse Hazard Important Two-Component Material Information Changing Materials Typical Installation, without Circulation Typical Installation, without Circulation Key for FIGTypical Installation, with Circulation Typical Installation, with CirculationIG Typical Installation Component IdentificationMain Air Filter Filters system air supply See Tempera- ture Controls and Indicators Temperature Controls and IndicatorsControl Panel Main Power Switch Size ComponentDetermine Power Source SetupLocate Reactor A-25 Electrical Requirements Configure to Supply Power Step One Connect Electrical CordHeater Jumpers WattsTerminal Blocks Ground System Fluid Supply Connections Iso Pump Lubrication System SetupAir Supply Connection Recirculation / Pressure Relief Lines Install Fluid Temperature Sensor FTSConnect Heated Hose Fusion AP Gun shown Load Fluid with Feed Pumps Initial StartupPressure Check Hose Set Temperatures Manual current control mode onlySupply Wet-Cups with Throat Seal Liquid Spraying ClosedSpray Adjustments SB SAShutdown Pressure Relief ProcedurePark Open CloseFlushing Daily Start-up Procedure OperationOpen gun fluid manifold valves a and B Fluid Circulation Circulation Through ReactorCirculation Through Gun Manifold Circulation Kit CK Part Gun ManualRun Mode DataTrak Controls and IndicatorsSetup Mode See DataTrak Diagnostic Codes Setup ModeRun Mode DataTrak OperationMaintenance DataTrak Diagnostic Codes Diagnostic CodesTemperature Control Diagnostic Codes Symbol Code Code Name Diagnosis CauseDimensions With Wheels Without Wheels Dimension In. mmTechnical Data Category DataGraco Standard Warranty Graco Information
Related manuals
Manual 56 pages 23.25 Kb