Majestic Appliances LDVR1 installation instructions Below Grade Installations

Page 18

LDVR Series Direct Vent Gas Fireplace

X

Always install hori- zontal venting on a level plane.

CFM136

Fig. 28 Measure horizontal length including 2” overlap.

X

X

CFM138

Fig. 30 Horizontal length requirement.

High

X

Below Grade Installations

Temperature Sealant

CFM137

Fig. 29 Apply high temperature sealant.

STEP 6

Guide the vent termination’s 4” (102 mm) and 7” (178

mm)collars into their respective vent pipes. Double check that the vent pipes overlap the collars by 2” (51

mm).Secure the termination to the wall with screws pro- vided and caulk around the wall plate to weatherproof. (Fig. 30)

STEP 7

Support the horizontal pipes every 36” (914 mm) with metal pipe straps. Make sure that the horizontal vent pipe is installed on a level horizontal plane.

STEP 8

Re-check the fireplace to make sure that it is levelled, properly positioned, and nailed or screwed to the floor. If applied, the fireplaces adjustable frame drywall strips (nailing flanges) should be fastened. Refer to “Framing & Finishing”.

When it is not possible to meet the required vent ter- minal clearances of 12” (305 mm) above grade level a snorkel vent kit #7TDVSNORK is required. It allows installation depth of down to 7” (178 mm) below grade level. The 7” is measured from the center of the hori- zontal vent pipe as it penetrates through the wall.

If venting system is installed below ground, we recommend a window well with adequate and proper drainage.

Ensure sidewall venting clearances are ob- served.

The maximum horizontal run with 24” vertical rise is 36” (914 mm) from the back of the fireplace to the face of the exterior wall. See vent graph (Page 12) for extended horizontal run if the vertical rise exceeds 24” (610 mm).

1.Establish vent hole through the wall. (Fig. 25)

2.Remove soil to a depth of approximately 16” (406mm) below base of snorkel. Install window well (not supplied). Refill hole with 12” (305 mm) of coarse gravel leaving a clearance of approximately 4” (102 mm) below snorkel. (Fig. 31)

3.Install vent system. See Page 13, Steps 2 through 5.

4.Ensure a watertight seal is made around the vent pipe coming through the wall.

5.Apply high temperature sealant caulking (supplied) around the 4” and 7” snorkel collars.

6.Slide into the vent pipe and secure to the wall.

7.Level the soil to maintain a 4” (102 mm) clearance below snorkel. (Fig. 31)

18

10007317

Image 18
Contents Builder Rear Vent Direct Vent Table of Contents Installation & Operating Instructions 33LDVR / 36LDVR / 39LDVR / 43LDVR Certified ToAnsi Z21.88-2005 / CSA Vented Gas Fireplace Heaters Requirements for the Commonwealth of Massachusetts Gas Equipment Venting System not ProvidedFireplace Dimensions Framing DimensionsClearance to Combustibles Mantel ChartLocating Your Fireplace MantelsFinal Finishing HearthFraming and Finishing Gas SpecificationsAlternate Switch Location Gas Line InstallationRemote ON/OFF Switch InstallationEB-1 Electrical Box Electronic Gas Control ValveGeneral Venting Location of Vent TerminationCanadian Installations1 US Installations2 General Venting Information Termination LocationGeneral Information Assembling Vent Pipes Canadian InstallationsUSA Installations Flex Vent PipesRear Wall Venting Applications How to Use the Vent GraphTwist Lock Pipes Example aRear Wall Installation Twist Lock Pipe StepRear Wall Vent Installations Flex Vent Pipe StepVertical Sidewall Applications Maximum number of 90 elbows is three Vertical Sidewall Installation Zero clearance sleeve is only required for combustible wallsBelow Grade Installations Measure horizontal length including 2 overlapVertical Through-the-Roof Applications This Gas Fireplace has been approved forVertical Through-the-Roof Installation Typical vertical roof applicationsMin 610 mm Venting Components Operating Instructions Glass CleaningWindow Frame Assembly Removal Glass InformationInstallation of Logs, Lava Rock & Ember Material Log Identification ChartLog Installation Rial on the burner housing assembly Do not place any of the lava rock mateOn the burner housing assembly Flame CharacteristicsFlame & Temperature Adjustment Do not place any of the lava rock material33LDVR Lighting and Operating Instructions To Turn Off Gas To HeaterLighting Instructions Turning Off the Gas to the ApplianceValve in the on position Troubleshooting Honeywell Millivolt Valve Troubleshooting the Gas Control System Normal Operation Abnormal OperationSIT 820 Nova Gas Control Valve Fig Fuel Conversion InstructionsPSE Pilot SIT top Convertible PilotBurner and Burner Compartment MaintenanceCleaning the Standing Pilot Control System Brass Trim33/36/39/43LDVR Ldvr DescriptionFuel Conversion Kits Optional Accessories Available FK24 Fan AssemblyFan Kits Ceramic Refractory Panels Wiring InstructionsRemote Controls Model Function/s ControlledScreen Door Kit Optional Trim KitsLouvre Accent Trim Filigree Louvre KitLdvr Series Direct Vent Gas Fireplace Ldvr Series Direct Vent Gas Fireplace Ldvr Series Direct Vent Gas Fireplace Limited Lifetime Warranty Efficiency Ratings AFUE%