Majestic Appliances LDVR1 Maintenance, Cleaning the Standing Pilot Control System, Brass Trim

Page 33

LDVR Series Direct Vent Gas Fireplace

Regulator Cap

O

L

 

Conversion Screw

Pressure Regulator Housing

HV120

12.After bleeding the gas line and checking for leaks with a soap solution, replace the window frame assembly. Fire up the unit, check for flame impinge- ment on the logs, adjusting them if necessary. Check the manifold and supply pressures against the appli- ance specifications.

Fig. 51 Honeywell Gas Valve.

Maintenance

Burner and Burner Compartment

It is important to keep the burner and the burner compartment clean. At least once per year the logs and lava rock/ember material should be removed and the burner compartment vacuumed and wiped out. Remove and refit the logs as per the instructions in this manual.

Always handle the logs with care as they are fragile and may also be hot if the

fireplace has been in use. FK24/FK12 Fan Assembly

The fan unit requires periodic cleaning. At least once per month in the operating season open the lower louvre panels and wipe or vacuum the area around the fan to remove any build up of dust or lint.

Brass Trim

Clean the brass trim pieces using a soft cloth lightly dampened with lemon oil. Do not use water or household cleaners on any brass components.

Cleaning the Standing

Pilot Control System

The burner and control system consist of:

burner

gas orifice

pilot assembly

thermopile

millivolt gas valve

Most of these components may require only an occasional checkup and cleaning and some may require adjustment. If repair is necessary, it should be performed by a qualified technician.

1.Turn off pilot light at gas valve.

2.Allow fireplace to cool if it has been operating.

3.Remove window frame assembly. (Refer to Window Frame Assembly Removal section.)

4.Remove logs.

5.Vacuum burner compartment especially around orifice primary air openings.

6.Visually inspect pilot. Brush or blow away any dust or lint accumulation.

7.Reinstall logs.

8.Ignite pilot - Refer to Lighting Instructions.

9.Reinstall window frame assembly.

To obtain proper operation, it is imperative that the pilot and burner’s flame characteristics are steady, not lifting or floating.

Typically, the top 3/8” to 1/2” of the thermopile should be engulfed in the pilot flame. (Refer to Page 25, Figure 47)

To adjust pilot burner: (by qualified service technician)

1.Remove pilot adjustment cap

2.Adjust pilot screw to provide properly sized flame.

3.Replace pilot adjustment cap.

The primary air shutter is set at factory and should only be adjusted, if necessary, by a qualified service technician.

10007317

33

Image 33
Contents Builder Rear Vent Direct Vent Table of Contents Installation & Operating Instructions 33LDVR / 36LDVR / 39LDVR / 43LDVR Certified ToAnsi Z21.88-2005 / CSA Vented Gas Fireplace Heaters Gas Equipment Venting System not Provided Requirements for the Commonwealth of MassachusettsFraming Dimensions Fireplace DimensionsLocating Your Fireplace Mantel ChartClearance to Combustibles MantelsFraming and Finishing HearthFinal Finishing Gas SpecificationsRemote ON/OFF Switch Gas Line InstallationAlternate Switch Location InstallationElectronic Gas Control Valve EB-1 Electrical BoxLocation of Vent Termination General VentingGeneral Venting Information Termination Location Canadian Installations1 US Installations2USA Installations Canadian InstallationsGeneral Information Assembling Vent Pipes Flex Vent PipesTwist Lock Pipes How to Use the Vent GraphRear Wall Venting Applications Example aStep Rear Wall Installation Twist Lock PipeRear Wall Vent Installations Flex Vent Pipe StepVertical Sidewall Applications Maximum number of 90 elbows is three Zero clearance sleeve is only required for combustible walls Vertical Sidewall InstallationMeasure horizontal length including 2 overlap Below Grade InstallationsThis Gas Fireplace has been approved for Vertical Through-the-Roof ApplicationsTypical vertical roof applications Vertical Through-the-Roof InstallationMin 610 mm Venting Components Window Frame Assembly Removal Glass CleaningOperating Instructions Glass InformationInstallation of Logs, Lava Rock & Ember Material Log Identification ChartLog Installation Do not place any of the lava rock mate Rial on the burner housing assemblyFlame & Temperature Adjustment Flame CharacteristicsOn the burner housing assembly Do not place any of the lava rock material33LDVR To Turn Off Gas To Heater Lighting and Operating InstructionsLighting Instructions Turning Off the Gas to the ApplianceValve in the on position Troubleshooting Honeywell Millivolt Valve Normal Operation Abnormal Operation Troubleshooting the Gas Control SystemPSE Pilot Fuel Conversion InstructionsSIT 820 Nova Gas Control Valve Fig SIT top Convertible PilotCleaning the Standing Pilot Control System MaintenanceBurner and Burner Compartment Brass Trim33/36/39/43LDVR Description LdvrFuel Conversion Kits Optional Accessories Available FK24 Fan AssemblyFan Kits Remote Controls Wiring InstructionsCeramic Refractory Panels Model Function/s ControlledLouvre Accent Trim Optional Trim KitsScreen Door Kit Filigree Louvre KitLdvr Series Direct Vent Gas Fireplace Ldvr Series Direct Vent Gas Fireplace Ldvr Series Direct Vent Gas Fireplace Limited Lifetime Warranty AFUE% Efficiency Ratings