Majestic Appliances LDVR1 Optional Accessories Available, Fan Kits, FK24 Fan Assembly

Page 37

LDVR Series Direct Vent Gas Fireplace

Optional Accessories Available

Fan Kits

FK24 Fan Assembly

This auxiliary fan system increases the efficiency of the circulation of the heated air.

The FK24 fan kit allows variable speed control of the circulation fan and also incorporates a heat sensor in the circuit.

Specifications

115 Volt / 60Hz / 56 Watts

Maintenance

The fan itself does not require regular maintenance, however periodic cleaning of the fan and the surrounding area is required.

Check the area under the control door (lower louvre assembly) and in front of the fan and wipe or vacuum this area at least once a month during the operating season.

Installation

The fan assembly and other components are supplied fully wired, eliminating the need for a licensed electrician to carry out the installation.

If hard wiring the fan using Method B (following) we strongly recommend the use of a licensed electrician.

1.Open the lower louvre assembly. Move the fan & bracket assembly around the gas valve and lines to locate the unit onto the screw studs on the back of the fireplace.

2.Install the thermal sensor under the bottom of the of the firebox, locating it over the two 10mm studs and secure it with nuts.

3.Locate the fan speed control unit. This can be fitted behind the lower louvre assembly as in Figure 52 or located remotely in a conveniently located wall mounted electrical box. Remote location of the speed control will require suitable extension of the component wiring.

4.The power supply may be connected in two ways:

Method A

Route the 6’ lead fitted to the unit to a conveniently located wall socket.

Method B (Using EB-1 Receptacle Box)

The EB-1 receptacle box (Pt. # ZA1200) may be hard wired into the house supply. The fan lead is then plugged into the EB-1 box. For instruction on wiring the EB-1 receptacle box see the earlier chapter in the Installation section of this manual.

Thermal

 

Sensor

Fan

 

 

Valve

 

Fan Speed

Gas

EB-1 Recep-

tacle Box

FP1230 Switch

Lines

 

Fig. 52 FK24 fan placement.

FK12

This auxiliary fan system increases the efficiency of the circulation of the heating air.

The FK12 Fan Assembly is a fixed speed fan system and does not allow for variable speed control. It does not use the speed control unit or the heat sensor used in the FK24 Kit.

Specifications

115 Volts / 60 Hz / 56 Watts.

Maintenance

The fan itself does not require regular maintenance, however periodic cleaning of the fan and the surrounding area is required.

Check the area under the control door (lower louvre assembly) and in front of the fan and wipe or vacuum this area at least once a month during the operating season.

Installation

The fan assembly is supplied fully wired eliminating the need for a licensed electrician to carry out the installation.

1.Open the lower Louvre assembly. Move the fan & bracket assembly around the gas valve and lines to locate the unit against the back wall of the appliance, resting on the base.

2.With the protective cover removed from the self- adhesive ‘Velcro’ strips apply mild pressure to the fan & bracket unit to secure the strips to the metal panels. No further securing is required.

3.Power to the fan can be supplied by plugging the supplied lead into a conveniently located wall socket or by using a hard-wired EB-1 receptacle box.

10007317

37

Image 37
Contents Builder Rear Vent Direct Vent Table of Contents 33LDVR / 36LDVR / 39LDVR / 43LDVR Certified To Installation & Operating InstructionsAnsi Z21.88-2005 / CSA Vented Gas Fireplace Heaters Gas Equipment Venting System not Provided Requirements for the Commonwealth of MassachusettsFraming Dimensions Fireplace DimensionsLocating Your Fireplace Mantel ChartClearance to Combustibles MantelsFraming and Finishing HearthFinal Finishing Gas SpecificationsRemote ON/OFF Switch Gas Line InstallationAlternate Switch Location InstallationElectronic Gas Control Valve EB-1 Electrical BoxLocation of Vent Termination General VentingGeneral Venting Information Termination Location Canadian Installations1 US Installations2USA Installations Canadian InstallationsGeneral Information Assembling Vent Pipes Flex Vent PipesTwist Lock Pipes How to Use the Vent GraphRear Wall Venting Applications Example aStep Rear Wall Installation Twist Lock PipeStep Rear Wall Vent Installations Flex Vent PipeVertical Sidewall Applications Maximum number of 90 elbows is three Zero clearance sleeve is only required for combustible walls Vertical Sidewall InstallationMeasure horizontal length including 2 overlap Below Grade InstallationsThis Gas Fireplace has been approved for Vertical Through-the-Roof ApplicationsTypical vertical roof applications Vertical Through-the-Roof InstallationMin 610 mm Venting Components Window Frame Assembly Removal Glass CleaningOperating Instructions Glass InformationLog Identification Chart Installation of Logs, Lava Rock & Ember MaterialLog Installation Do not place any of the lava rock mate Rial on the burner housing assemblyFlame & Temperature Adjustment Flame CharacteristicsOn the burner housing assembly Do not place any of the lava rock material33LDVR To Turn Off Gas To Heater Lighting and Operating InstructionsTurning Off the Gas to the Appliance Lighting InstructionsValve in the on position Troubleshooting Honeywell Millivolt Valve Normal Operation Abnormal Operation Troubleshooting the Gas Control SystemPSE Pilot Fuel Conversion InstructionsSIT 820 Nova Gas Control Valve Fig SIT top Convertible PilotCleaning the Standing Pilot Control System MaintenanceBurner and Burner Compartment Brass Trim33/36/39/43LDVR Description LdvrFuel Conversion Kits FK24 Fan Assembly Optional Accessories AvailableFan Kits Remote Controls Wiring InstructionsCeramic Refractory Panels Model Function/s ControlledLouvre Accent Trim Optional Trim KitsScreen Door Kit Filigree Louvre KitLdvr Series Direct Vent Gas Fireplace Ldvr Series Direct Vent Gas Fireplace Ldvr Series Direct Vent Gas Fireplace Limited Lifetime Warranty AFUE% Efficiency Ratings