Majestic Appliances LDVR1 Operating Instructions, Glass Information, Louvre Removal

Page 23

LDVR Series Direct Vent Gas Fireplace

Operating Instructions

Glass Information

Only glass approved by CFM Corporation should be used on this fireplace.

The use of any non-approved replacement glass will void all product warranties.

Care must be taken to avoid breakage of the glass.

Do not operate appliance with glass front removed, cracked or broken.

Replacement glass (complete with frame window) is available through your CFM Corporation dealer and should only be installed by a licensed qualified service person.

�������

��������������

������������

������������������

�������������

��������������������

���������������

Louvre Removal

6.Tilt the window frame assembly out slightly at the bottom, lift the window frame assembly up and away from the fireplace.

7.To replace the window frame assembly reverse the procedure.

Lower Clamps

 

Window

 

Frame

Window

Assembly

 

Frame

Pull Clamp

Assembly

Hook

Push

Clamp

 

Handle

FP1228

 

Fig. 40 Window frame assembly removal.

Glass Cleaning

The top louvre panel is removed by lifting the panel vertically and pulling it away from the appliance. (Fig. 39) The lower access door is hinged along the bottom edge and is folded down to allow access.

2.

Louvre

1.

Glass Panel

FP1227

Fig. 39 Remove top louvre assembly.

It is necessary to periodically clean glass. During start- up condensation, which is normal, forms on the inside of the glass. This condensation causes lint, dust and other airborne particles to cling to glass surface.

Also initial paint curing may deposit a slight film on the glass. It is therefore recommended the glass be cleaned two or three times with a non-ammonia based household cleaner and warm water (We recommend gas fireplace glass cleaner) within the first few weeks of operation.

After the initial cleaning process the glass should be cleaned two or three times during each operating season depending on the environment in the house.

Window Frame Assembly Removal

1.Turn the fireplace OFF (including the pilot)

2.If the unit has been operating allow time for the components to cool.

3.Remove the top louvre assembly.

4.Open the lower louvre panel.

5.Release the two clamps securing the lower edge of the window frame assembly by pulling down on the handles. (Fig. 40)

Clean glass after first two weeks of operation.

Do not clean glass when hot. Do not use abrasive cleaners. Do not strike or slam the glass.

10007317

23

Image 23
Contents Builder Rear Vent Direct Vent Table of Contents Ansi Z21.88-2005 / CSA Vented Gas Fireplace Heaters Installation & Operating Instructions33LDVR / 36LDVR / 39LDVR / 43LDVR Certified To Gas Equipment Venting System not Provided Requirements for the Commonwealth of MassachusettsFraming Dimensions Fireplace DimensionsMantels Mantel ChartLocating Your Fireplace Clearance to CombustiblesGas Specifications HearthFraming and Finishing Final FinishingInstallation Gas Line InstallationRemote ON/OFF Switch Alternate Switch LocationElectronic Gas Control Valve EB-1 Electrical BoxLocation of Vent Termination General VentingGeneral Venting Information Termination Location Canadian Installations1 US Installations2Flex Vent Pipes Canadian InstallationsUSA Installations General Information Assembling Vent PipesExample a How to Use the Vent GraphTwist Lock Pipes Rear Wall Venting ApplicationsStep Rear Wall Installation Twist Lock PipeVertical Sidewall Applications Rear Wall Vent Installations Flex Vent PipeStep Maximum number of 90 elbows is three Zero clearance sleeve is only required for combustible walls Vertical Sidewall InstallationMeasure horizontal length including 2 overlap Below Grade InstallationsThis Gas Fireplace has been approved for Vertical Through-the-Roof ApplicationsTypical vertical roof applications Vertical Through-the-Roof InstallationMin 610 mm Venting Components Glass Information Glass CleaningWindow Frame Assembly Removal Operating InstructionsLog Installation Installation of Logs, Lava Rock & Ember MaterialLog Identification Chart Do not place any of the lava rock mate Rial on the burner housing assemblyDo not place any of the lava rock material Flame CharacteristicsFlame & Temperature Adjustment On the burner housing assembly33LDVR To Turn Off Gas To Heater Lighting and Operating InstructionsValve in the on position Lighting InstructionsTurning Off the Gas to the Appliance Troubleshooting Honeywell Millivolt Valve Normal Operation Abnormal Operation Troubleshooting the Gas Control SystemSIT top Convertible Pilot Fuel Conversion InstructionsPSE Pilot SIT 820 Nova Gas Control Valve FigBrass Trim MaintenanceCleaning the Standing Pilot Control System Burner and Burner Compartment33/36/39/43LDVR Description LdvrFuel Conversion Kits Fan Kits Optional Accessories AvailableFK24 Fan Assembly Model Function/s Controlled Wiring InstructionsRemote Controls Ceramic Refractory PanelsFiligree Louvre Kit Optional Trim KitsLouvre Accent Trim Screen Door KitLdvr Series Direct Vent Gas Fireplace Ldvr Series Direct Vent Gas Fireplace Ldvr Series Direct Vent Gas Fireplace Limited Lifetime Warranty AFUE% Efficiency Ratings