Cal Flame LTR20081044 Installing the Transformer, LP Gas Hook Up, Transporting and Storing LP Gas

Page 7

The grill unit must be used with the gas pressure regula- tor. The regulator will control and maintain a uniform gas pressure in the manifold. The burner orifices have been sized for the gas pressure delivered by the regulator.

WARNING: Attempting to operate the grill unit without the gas regulator installed could cause an explosion and possible death.

LP Gas Hook Up

An enclosure for an LP gas cylinder shall be vented by openings at the level of the cylinder valve and at floor level. The effectiveness of the openings for purposes of ventilation shall be determined with the LP-gas supply cylinder in place. This shall be accomplished in one of the following manners:

1.One side of the enclosure shall be completely open.

2.Enclosures that have four sides, complete with a top and bottom:

a.At least two ventilation openings at cylinder valve level shall be provided in the sidewall, equally sized, spaced at 180º (3.14 rad), and unobstructed. Each opening shall have a to- tal free area of not less than 7.1 cm²/kg (one square inch per pound) of stored fuel capacity, and not less than a total free area of 64.5 cm²

(10 square inches).

b.Ventilation openings shall be provided at floor level and shall have a total free area of not less than 7.1 cm²/kg (one square inch per pound) of stored fuel capacity and not less than a to-

Installation / Assembly

tal free area of 64.5cm² (10 square inches). If ventilation openings at floor level are in a side- wall, there shall be at least two openings. The bottom of the openings shall be at floor level and the upper edge no more than 127 mm (5 inches) above the floor. The openings shall be equally sized, spaced at 180º (3.14 rad) and un- obstructed.

c.Every opening shall have minimum dimensions so as to permit the entrance of a 3.2 mm (1/8 inch) diameter rod.

Transporting and Storing LP Gas

Transport only one cylinder at a time. Ensure the cylinder is secured in an upright position with the control valve turned off and the dust cap in place. Store cylinders out- doors and out of reach of children. Do not store cylinders in a building, garage, or any other enclosed area.

Installing the Transformer

All grills with electrical components such as lights or a convection fan will require the transformer to be installed and plugged in before you can use it. This needs to be done before the grill is inserted in the barbecue island. When the transformer is attached to the grill chassis, use care in placing the grill in the island cutout to avoid hitting the transformer.

Cal Flame 2008 Owner’s Manual

Page 5

LTR20081044, Rev. A

Image 7
Contents LTR20081044, Rev. a 4/21/08 Appendix Safety Instructions Installation / AssemblyCleaning and Maintenance Operating Your BarbecueSet-Up Safety InstructionsPlacement and Location Operation Precautions Regarding Children Maintenance and Repair Storage Cabinet Cut-out Dimensions Installation / AssemblyModel Number Description Width Depth Height Leak Testing ProcedureLiquid Propane Gas Tank RequirementsLP Gas Hook Up Installing the TransformerTransporting and Storing LP Gas Installing Grills in Barbecue Islands Installing the Rotisserie Installing Side Burners Grill Controls Operating Your BarbecueElectronically Lighting the Grill and Infra- red Burners Lighting the GrillManually Lighting the Grill and Infrared Burners Cooking with the Rotisserie Basic Grill OperationCooking with a Side Burner Light and Fan SwitchCooking with a Convection Grill Cleaning and Maintenance Light Replacement Light Bulb ReplacementLight Removal AppendixTroubleshooting Problem Misalignment of Igniter on Burner Problem Plugged orificeProblem Flashback Removing and Replacing Infrared Burners Replacement CoversGas category Grill SpecificationsLocation of Serial Number Plate Country of destination