Appendix
Problem: Plugged orifice
Solution: Unplug the orifice as follows:
•Remove cooking grills, flame tamer and grease tray.
•Remove burners from the bottom of the firebox by pulling the cotter pin from beneath the burner peg using a standard screwdriver or needle nose pliers.
•Carefully lift each burner up and away from the gas orifice.
•Remove the orifice from the control valve.
•Gently clear any obstruction with a fine wire.
•Reinstall the orifice, reinstall the burners over the orifices, and seat each burner peg into position hole at the bottom ledge of the firebox.
•Replace all cotter pins.
•Replace cooking components and grease collectors.
If an obstruction is suspected in the control valve, contact your local Cal Flame dealer for assis- tance.
Problem: Misalignment of Igniter on Burner
Solution: • Check for proper position of the electrode tip, which should be pointing forward towards the front of the burner and free of grease to allow proper sparking.
•The ignition wire should be connected firmly to the valve ignition device and electrode. Replace the ignition wire if it is frayed or cracked.
•With the gas supply closed and all control knobs set to the off position, check each position igniter individually for the presence of a spark at the electrode. Push each knob in fully and rotate it about 1/4 turn to the left
•While the grill is still hot, wait for a minimum of five minutes before commencing
Problem: Flashback
Solution: When fire occurs in and around the burner tubes, immediately turn off gas at its source and turn the control knob clockwise to the ‘OFF’ position. Wait until the grill has cooled off and then clean the burner tubes and burners as described on page of this manual.
Page 16 | Cal Flame 2008 Owner’s Manual |
LTR20081044, Rev. A