Jackson 850BI Series, 700 Series Main Gas Line Connections for Propane Gas and Natural Gas

Page 13

Main Gas Line Connections for Propane Gas and Natural Gas.

The main Fuel supply gas line is connected to a Manifold Tee securely mounted inside the pedestal located on the left hand side of the pedestal.

Remove the Propane hose and regulator assembly from the packaging. Please ensure that there is no debris inside the brass flare connection or inside the rubber hose. Using a ¾” wrench and an adjustable wrench tighten the Hose to the connection provided inside the pedestal.

If this unit is to be connected to Natural Gas, place the Natural Gas hose through the hole provided in the lower left hand rear corner of the pedestal. This hole should have a rubber grommet around the hole to protect the Hose from getting damaged. See diagram below.

Place the Propane Hose and regulator on the Manifold located inside the pedestal.

For Natural Gas hose installations, place the hose through the hole in

the back of the pedestal and connect in the same

location as the Propane Hose location.

Once the Main Gas line has been connected, connect the fuel line to the Gas supply being used. Turn the gas on SLOWLY, if the gas is turned on too quickly the Regulator could lock up and not work correctly. By turning the main gas supply on slowly this will prevent this problem form happening.

When the gas supply has been turn on, perform a Leak Check on ALL connections inside the pedestal using a Soapy water solution as described on Page 7 of this manual.

13

Image 13
Contents Certified for Canada and U.S.A DO’S and DON’TS Table of ContentsFor Your Safety SafetyElectrical Caution Specifications LP GAS Cylinder PlacementLP GAS Cylinder QCC-1 Quick Closing CouplingStorage HandlingOperation Identification OPD Equipped CylinderHose and Regulator ConnectionLeak Test Important Safety InformationClearances and Dimensions Installation18.5 Min 700BI 850 BI 32.5 39.5 10.25 17.25 24.25 24 min700BI ZC 34.75 41.75 10.25 17.25 24.25 19.5Side Shelf Installation AssemblyRotisserie KIT Installation If Equipped Upper Flavor Shield, Cooking Grid Installation Rotisserie Kit Completed InstallationMain Gas Line Connections for Propane Gas and Natural Gas Getting To Know Your Grill Rear Burner Lighting If equipped Manual Burner Lighting Main BurnerOperating The Rear Burner Natural GAS InstallationsMain Burner USE Converting from Propane Gaslp to Natural GASRear Burner Side Burner Burner Removal for Cleaning MaintenanceGAS Line Burner Inspection Please inspect these burners once a yearRotisserie Cooking Food Safety Tips and TechniquesDo not let the drip tray dry out Valve turned to high Low heat or low flame whenExcessive flare-ups or Un-even heatPart Number Part Description Quantity Parts ListExploded View Jackson Grills Limited Lifetime Warranty Jackson Grills Inc Jacob Road, Duncan, B.C V9L 6W4 Or Fax Special message to our customers