Jackson 850BI Series LP GAS Cylinder Placement, Specifications, QCC-1 Quick Closing Coupling

Page 4

LP GAS CYLINDER PLACEMENT:

Cylinders must be installed according to assembly instructions. Install the gas cylinder into the tank hole inside of the Jackson Pedestal.

LP GAS CYLINDER:

QCC-1 Quick Closing Coupling

Your grill is designed to be used with an LP gas cylinder equipped with the new QCC-1 Quick Closing Coupling system. The QCC-1 system incorporates new safety features required by the Canadian Standards Steering Committee and the American National Standards Institute (ANSI).

ƒGas will not flow until a positive connection has been made.

ƒA thermal element will shut off flow of gas between 240 degrees and 300 degrees F. When activated, a flow-limiting device will limit the flow of gas to 10 cubic feet per hour.

The LP Gas Cylinder is not included with the Gas Grill. Be

sure to purchase one with the QCC valve. The external threadson the inlet port of the valve recognize this valve. QCC equipped

cylinders are available from your gas grill dealer. Any attempt to

connect the regulator, by use of adapters or any other means, to any other valve could result in damage or fire, and may negate the important safety features designed into the QCC-1 system.

SPECIFICATIONS:

All LP gas cylinders used with this appliance must be constructed and marked with the specifications for LP cylinders in accordance with the Canadian Transport Commission (CTC)

1.or the US Department of Transport (DOT) for use in the USA.

2.The LP gas cylinder used for this appliance must not have a capacity larger than 20 lb. (9 kg): approximately 18” (46cm) high & 12” (30cm) diameter.

3.All LP gas cylinders used with this appliance should be inspected at every filling and re-qualified by a licensed service outlet at the expiry date (10 years) in accordance with DOT (USA) and CTC (Canada) codes for LP gas cylinders.

4.All LP gas cylinders used with the appliance must be provided with a shut off valve terminating in a cylinder valve outlet No. 510, specified in the Standard for Compressed Gas Cylinder Valve Outlet and Inlet Connections (USA) ANSI / CGA-V-11977 (Canada) CSA B96.

The cylinder supply system must be arranged for vapor withdrawal. The cylinder must also include a collar to protect the cylinder valve. As well, the cylinder valve must include a safety relief device having direct communication with the vapor space of the cylinder.

4

Image 4
Contents Certified for Canada and U.S.A Table of Contents DO’S and DON’TSFor Your Safety SafetyElectrical Caution LP GAS Cylinder Placement SpecificationsLP GAS Cylinder QCC-1 Quick Closing CouplingStorage HandlingOperation OPD Equipped Cylinder IdentificationHose and Regulator ConnectionImportant Safety Information Leak TestInstallation Clearances and Dimensions700BI 850 BI 32.5 39.5 10.25 17.25 24.25 24 min 18.5 Min700BI ZC 34.75 41.75 10.25 17.25 24.25 19.5Assembly Side Shelf InstallationRotisserie KIT Installation If Equipped Rotisserie Kit Completed Installation Upper Flavor Shield, Cooking Grid InstallationMain Gas Line Connections for Propane Gas and Natural Gas Getting To Know Your Grill Manual Burner Lighting Main Burner Rear Burner Lighting If equippedNatural GAS Installations Operating The Rear BurnerMain Burner USE Converting from Propane Gaslp to Natural GASRear Burner Side Burner Maintenance Burner Removal for CleaningGAS Line Burner Inspection Please inspect these burners once a yearRotisserie Cooking Food Safety Tips and TechniquesDo not let the drip tray dry out Low heat or low flame when Valve turned to highExcessive flare-ups or Un-even heatParts List Part Number Part Description QuantityExploded View Jackson Grills Limited Lifetime Warranty Special message to our customers Jackson Grills Inc Jacob Road, Duncan, B.C V9L 6W4 Or Fax