Rinnai 4500 Prepare Framing Dimensions, Attach Metal Lintel and Angled Clearance Brackets

Page 15

Installing Body Assembly in an Open 1-Sided or 2-Sided Installation

Steel framing options are available for the open 1-sided and open 2-sided installations. For ease of installation, Rinnai provides a steel frame as a kit. Refer to the separate detailed instructions for assembly of the steel frame.

 

Minimum Clearance to Combustibles

 

 

Above

NOT ALLOWED

 

 

Side

1.0 in (25 mm)

 

 

Below

0

 

 

Behind

1.2 in (30 mm)

 

 

To enhance the durability of any type of framing, it is suggested that the frame is mounted on a paved slab

9.5inches (250 mm) above unpaved ground and 5.9 inches (150 mm) above paved ground.

Prepare Framing Dimensions

If framing is made of a combustible material, ensure the following minimum framing dimensions and clearances:

Cross members above the appliance must be non-combustible.

Metal lintels are provided with the purchase of the 1- sided and 2-sided fireplaces. Metal lintels are also offered separately (R2629).

Non-combustible cladding is required over the entire frame.

Framing Dimensions

A21.8 in (555 mm)

B48.3 in (1225 mm) *

C (2-sided)

18.5 in (470 mm) **

C (1-sided)

19.7 in (500 mm) **

*Includes 1 in (25 mm) side clearances.

**Includes cladding (for 1-sided unit, this includes cladding on one side only)

Attach Metal Lintel and Angled Clearance Brackets

Metal Lintel

Designed to sit above the appliance and replace combustible framing in areas above the appliance.

To install:

1.Take out and undo 4 fastening screws at either end.

2.Flip side sections 180° and loosely refit screws.

3.Adjust to the desired length before tightening.

Parts Required

 

Metal

Angled

 

Lintels

Brackets

 

 

 

Open 1-sided Cabinet

1

4

 

 

 

Open 2-sided Cabinet

2

4

 

 

 

side sections need to be rotated 180° and secured into the framing above the appliance

Rinnai Corporation ROF4500

15

Image 15
Contents Rinnai Outdoor Fireplace Series Consumer Safety Information Table of ContentsSafety Behavior and Practices Safety Features Specifications TroubleshootingProblem Cause Solution With Fascia and Doors Dimensions DimensionsBody Assembly with Glass Doors Assembly SpecificationsBurner Assembly Body AssemblySample Installations Installation ApplicationsOperating Instructions Before Starting the ApplianceOperating the Appliance Visual Inspection of Flame MaintenanceMaintenance Task Procedure Weather ProtectionItems included in carton ROF4500 ROF4501 ROF4502 Installation InstructionsBefore Installation General InstructionsLPG Cylinder Enclosure Definition of an Outdoor Area Description Clearance Required Additional Detail ClearancesPrepare Surround Installing Freestanding or Enclosed Masonry ApplicationsInstall Burner Assembly Install Burn Media and Complete Gas ConnectionPrepare Framing Dimensions Attach Metal Lintel and Angled Clearance BracketsMetal Lintel Timber stud Attach Mounting Brackets Install Doors if ApplicableInstall Body Assembly into Frame Install Steel FrameLayer 3 Single Layer of 14 Pieces of Large Quartz Installing Burn MediaLayer 1 Pumice Layer 2 Single Layer of Small QuartzLPG Cylinder Complete Gas ConnectionGuidelines for Cladding and Finishes QTY Parts ListPanel Burner Body Item No Quantity Description ROF4501 ROF4502 Item No Quantity Description Item No Quantity Description Outdoor Fireplace 4500 Fireplace Warranty InformationLimited Warranty Consumer SupportLimitation on warranties How do I get service? What is not covered?Rinnai Cheminée Extérieur Series Instructions d’installation Table des matièresDéfinitions de sécurité Dispositifs de sécurité Comportements et pratiques de sécuritéDépannage Problème Raison SolutionDimensions de brûleur DimensionsBody Dimensionsde corpsLa vue est Au loin, 0.67 17 profondément Consoles darmature en acier Assemblée de brûleurAssemblée de corps Assemblée de corps avec les Portes en VerreAccessoires facultatifs Installations témoinOpérer lappareil Avant de commencer lappareilEntretien Protection contre les intempériesInspection visuelle de flame Articles inclus dans le carton ROF4500 ROF4501 ROF4502 Avant d’installationClôture de cylindre de LPG Définition dun secteur extérieur Description Espacements Information supplémentaire Requis EspacementsBordure plaquée Installation de lunité indépendante oumaçonnerie incluseInstallez le montage de brûleur Préparez la bordurePréparez les dimensions de encadrement Attachez le linteau en métal et les équerresLinteau en métal Ouvrez le Cabinet Dégrossi par DégrossiAttachez les supports Installez les portes si cest appropriéInstallez le montage de corps sur larmature Installez larmature en acierCouche 3 À une seule couche de 14 morceaux de grand quartz Installation des médias de brûlureCouche 1 Ponce Couche 2 À une seule couche du petit quartzCylindre-gas de propane liquide Accomplissez le raccordement de gazDirectives pour le revêtement et les finitions Qu’est-ce qui est couvert ? Quelle est la durée de cette couverture ?Quel est l’engagement de Rinnai ? Limitation des garanties implicites Rinnai Corporation ROF4500 Rinnai Corporation ROF4500 Rinnai’s other fine products