Rinnai 4500 installation manual Guidelines for Cladding and Finishes

Page 20

Guidelines for Cladding and Finishes

These are guidelines only. It is up to the installer to seek advice from the cladding supplier as to the correct application and specification of the material.

All materials and finishes directly above the appliance must be capable of withstanding the following temperatures:

with the door assembly installed 302° F (150° C)

without the door assembly installed 212° F (100° C)

Cladding materials shall be non-combustible and suitable for an outdoor environment.

If you are installing a door assembly, a heat rated material such as calcium silicate board must be above the fire. Such materials require installation and sealing in accordance with the supplier specification.

Rinnai accepts no responsibility for deterioration of cladding or finishes.

heat rated material capable of withstanding 302° F (150° C) is required above the appliance with the door assembly installed

20

Rinnai Corporation ROF4500

Image 20
Contents Rinnai Outdoor Fireplace Series Table of Contents Consumer Safety InformationSafety Behavior and Practices Safety Features Problem Cause Solution SpecificationsTroubleshooting Dimensions With Fascia and Doors DimensionsAssembly Specifications Burner AssemblyBody Assembly Body Assembly with Glass DoorsInstallation Applications Sample InstallationsOperating the Appliance Operating InstructionsBefore Starting the Appliance Maintenance Maintenance Task ProcedureWeather Protection Visual Inspection of FlameInstallation Instructions Before InstallationGeneral Instructions Items included in carton ROF4500 ROF4501 ROF4502LPG Cylinder Enclosure Definition of an Outdoor Area Clearances Description Clearance Required Additional DetailInstalling Freestanding or Enclosed Masonry Applications Install Burner AssemblyInstall Burn Media and Complete Gas Connection Prepare SurroundMetal Lintel Prepare Framing DimensionsAttach Metal Lintel and Angled Clearance Brackets Timber stud Install Doors if Applicable Install Body Assembly into FrameInstall Steel Frame Attach Mounting BracketsInstalling Burn Media Layer 1 PumiceLayer 2 Single Layer of Small Quartz Layer 3 Single Layer of 14 Pieces of Large QuartzComplete Gas Connection LPG CylinderGuidelines for Cladding and Finishes Parts List QTYPanel Burner Body Item No Quantity Description ROF4501 ROF4502 Item No Quantity Description Item No Quantity Description Warranty Information Limited WarrantyConsumer Support Outdoor Fireplace 4500 FireplaceHow do I get service? What is not covered? Limitation on warrantiesRinnai Cheminée Extérieur Series Définitions de sécurité Instructions d’installationTable des matières Comportements et pratiques de sécurité Dispositifs de sécuritéProblème Raison Solution DépannageLa vue est Au loin, 0.67 17 profondément Dimensions de brûleurDimensionsBody Dimensionsde corps Assemblée de brûleur Assemblée de corpsAssemblée de corps avec les Portes en Verre Consoles darmature en acierInstallations témoin Accessoires facultatifsAvant de commencer lappareil Opérer lappareilInspection visuelle de flame EntretienProtection contre les intempéries Avant d’installation Articles inclus dans le carton ROF4500 ROF4501 ROF4502Clôture de cylindre de LPG Définition dun secteur extérieur Espacements Description Espacements Information supplémentaire RequisInstallation de lunité indépendante oumaçonnerie incluse Installez le montage de brûleurPréparez la bordure Bordure plaquéeLinteau en métal Préparez les dimensions de encadrementAttachez le linteau en métal et les équerres Dégrossi Ouvrez le Cabinet Dégrossi parInstallez les portes si cest approprié Installez le montage de corps sur larmatureInstallez larmature en acier Attachez les supportsInstallation des médias de brûlure Couche 1 PonceCouche 2 À une seule couche du petit quartz Couche 3 À une seule couche de 14 morceaux de grand quartzAccomplissez le raccordement de gaz Cylindre-gas de propane liquideDirectives pour le revêtement et les finitions Quel est l’engagement de Rinnai ? Qu’est-ce qui est couvert ?Quelle est la durée de cette couverture ? Limitation des garanties implicites Rinnai Corporation ROF4500 Rinnai Corporation ROF4500 Rinnai’s other fine products