Rinnai 4500 installation manual Timber stud

Page 16

Installing Body Assembly in an Open 1-Sided or 2-Sided Installation

Angled Clearance

Designed to ensure combustible framing is greater than 1 inch (25 mm) from the sides of

Brackets

the unit as shown.

Top View

Open 1-sided

Cabinet

48.3 in (1225 mm) minimum

timber stud

non combustible

19.7 in

cabinet

(500 mm)

cladding

 

 

minimum

 

clearance

 

bracket

Top View

timber stud

Open 2-sided

 

Cabinet

 

clearance bracket

46.5in (1180 mm) minimum

47.0in (1195 mm) maximum

48.3in (1225 mm) minimum

cabinet

46.5in (1180 mm) minimum

47.0in (1195 mm) maximum

non combustible cladding

18.5 in

(470 mm) minimum

To install:

1.Measure the distance between studs to ensure clearances are adequate, horizon- tally and vertically.

2.Screw clearance brackets to the inner side of stud.

3.Ensure that the flat face of the clearance bracket is facing out as shown above.

Clad Surround

Refer to the section, Guidelines for Cladding and Finishes.

16

Rinnai Corporation ROF4500

Image 16
Contents Rinnai Outdoor Fireplace Series Table of Contents Consumer Safety InformationSafety Behavior and Practices Safety Features Troubleshooting SpecificationsProblem Cause Solution Dimensions With Fascia and Doors DimensionsAssembly Specifications Burner AssemblyBody Assembly Body Assembly with Glass DoorsInstallation Applications Sample InstallationsBefore Starting the Appliance Operating InstructionsOperating the Appliance Maintenance Maintenance Task ProcedureWeather Protection Visual Inspection of FlameInstallation Instructions Before InstallationGeneral Instructions Items included in carton ROF4500 ROF4501 ROF4502LPG Cylinder Enclosure Definition of an Outdoor Area Clearances Description Clearance Required Additional DetailInstalling Freestanding or Enclosed Masonry Applications Install Burner AssemblyInstall Burn Media and Complete Gas Connection Prepare SurroundAttach Metal Lintel and Angled Clearance Brackets Prepare Framing DimensionsMetal Lintel Timber stud Install Doors if Applicable Install Body Assembly into FrameInstall Steel Frame Attach Mounting BracketsInstalling Burn Media Layer 1 PumiceLayer 2 Single Layer of Small Quartz Layer 3 Single Layer of 14 Pieces of Large QuartzComplete Gas Connection LPG CylinderGuidelines for Cladding and Finishes Parts List QTYPanel Burner Body Item No Quantity Description ROF4501 ROF4502 Item No Quantity Description Item No Quantity Description Warranty Information Limited WarrantyConsumer Support Outdoor Fireplace 4500 FireplaceHow do I get service? What is not covered? Limitation on warrantiesRinnai Cheminée Extérieur Series Table des matières Instructions d’installationDéfinitions de sécurité Comportements et pratiques de sécurité Dispositifs de sécuritéProblème Raison Solution DépannageDimensionsBody Dimensionsde corps Dimensions de brûleurLa vue est Au loin, 0.67 17 profondément Assemblée de brûleur Assemblée de corpsAssemblée de corps avec les Portes en Verre Consoles darmature en acierInstallations témoin Accessoires facultatifsAvant de commencer lappareil Opérer lappareilProtection contre les intempéries EntretienInspection visuelle de flame Avant d’installation Articles inclus dans le carton ROF4500 ROF4501 ROF4502Clôture de cylindre de LPG Définition dun secteur extérieur Espacements Description Espacements Information supplémentaire RequisInstallation de lunité indépendante oumaçonnerie incluse Installez le montage de brûleurPréparez la bordure Bordure plaquéeAttachez le linteau en métal et les équerres Préparez les dimensions de encadrementLinteau en métal Dégrossi Ouvrez le Cabinet Dégrossi parInstallez les portes si cest approprié Installez le montage de corps sur larmatureInstallez larmature en acier Attachez les supportsInstallation des médias de brûlure Couche 1 PonceCouche 2 À une seule couche du petit quartz Couche 3 À une seule couche de 14 morceaux de grand quartzAccomplissez le raccordement de gaz Cylindre-gas de propane liquideDirectives pour le revêtement et les finitions Quelle est la durée de cette couverture ? Qu’est-ce qui est couvert ?Quel est l’engagement de Rinnai ? Limitation des garanties implicites Rinnai Corporation ROF4500 Rinnai Corporation ROF4500 Rinnai’s other fine products