Rinnai 4500 Installation Instructions, General Instructions, Before Installation

Page 10

Installation Instructions

General Instructions

Do not use substitute materials.

Use only parts certified with the appliance.

A qualified service technician should install the appliance and inspect it before use.

The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1.

The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa).

The appliance must be isolated from the gas supply piping system by closing its equipment shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa).

Refer to the conversion manual for converting the appliance to use natural gas.

Do not install this appliance indoors.

Before Installation

Check for Damage Check for damage. Do not install any damaged items. Check that you have all the components you require.

Read Instructions Before using the appliance please read the entire manual to ensure correct use. Failure to follow these instructions could cause a malfunction of the appliance. This could result in death, serious injury and /or property damage. Failure to follow these instructions may also void your warranty.

Appliance Location Choose a location that meets the clearances to combustibles and non-combustibles. Avoid locating the appliance near trees or bushes. Take into account how the appliance is to be supplied with gas.

Items included in carton

ROF4500

ROF4501

ROF4502

 

 

 

 

 

R2615

Frame Trim SS 40 mm

NA

1

2

 

 

 

 

 

R2629

Metal Lintel Kit - includes 11254 lintel x 1 pc;

NA

1

2

 

11255 lintel end x 2 pcs; 9154 screw x 8 pcs

 

 

 

309000012

Installation Spacer Bracket (angle bracket)

NA

4

4

 

 

 

 

 

R2614

Conversion Kit LPG-NG

1

1

1

 

 

 

 

 

309000013

Pumice 4 kg bag

1

1

1

 

 

 

 

 

309000024

Quartz Small Crushed 4 kg

1

1

1

 

 

 

 

 

309000025

Quartz Large Rumbled 14 pieces

1

1

1

 

 

 

 

 

309000016

Weather Shield Assembly

1

1

1

 

 

 

 

 

11320

Owner’s Operation and Installation Manual

1

1

1

 

 

 

 

 

10

Rinnai Corporation ROF4500

Image 10
Contents Rinnai Outdoor Fireplace Series Table of Contents Consumer Safety InformationSafety Behavior and Practices Safety Features Troubleshooting SpecificationsProblem Cause Solution Dimensions With Fascia and Doors DimensionsBody Assembly Assembly SpecificationsBurner Assembly Body Assembly with Glass DoorsInstallation Applications Sample InstallationsBefore Starting the Appliance Operating InstructionsOperating the Appliance Weather Protection MaintenanceMaintenance Task Procedure Visual Inspection of FlameGeneral Instructions Installation InstructionsBefore Installation Items included in carton ROF4500 ROF4501 ROF4502LPG Cylinder Enclosure Definition of an Outdoor Area Clearances Description Clearance Required Additional DetailInstall Burn Media and Complete Gas Connection Installing Freestanding or Enclosed Masonry ApplicationsInstall Burner Assembly Prepare SurroundAttach Metal Lintel and Angled Clearance Brackets Prepare Framing DimensionsMetal Lintel Timber stud Install Steel Frame Install Doors if ApplicableInstall Body Assembly into Frame Attach Mounting BracketsLayer 2 Single Layer of Small Quartz Installing Burn MediaLayer 1 Pumice Layer 3 Single Layer of 14 Pieces of Large QuartzComplete Gas Connection LPG CylinderGuidelines for Cladding and Finishes Parts List QTYPanel Burner Body Item No Quantity Description ROF4501 ROF4502 Item No Quantity Description Item No Quantity Description Consumer Support Warranty InformationLimited Warranty Outdoor Fireplace 4500 FireplaceHow do I get service? What is not covered? Limitation on warrantiesRinnai Cheminée Extérieur Series Table des matières Instructions d’installationDéfinitions de sécurité Comportements et pratiques de sécurité Dispositifs de sécuritéProblème Raison Solution DépannageDimensionsBody Dimensionsde corps Dimensions de brûleurLa vue est Au loin, 0.67 17 profondément Assemblée de corps avec les Portes en Verre Assemblée de brûleurAssemblée de corps Consoles darmature en acierInstallations témoin Accessoires facultatifsAvant de commencer lappareil Opérer lappareilProtection contre les intempéries EntretienInspection visuelle de flame Avant d’installation Articles inclus dans le carton ROF4500 ROF4501 ROF4502Clôture de cylindre de LPG Définition dun secteur extérieur Espacements Description Espacements Information supplémentaire RequisPréparez la bordure Installation de lunité indépendante oumaçonnerie incluseInstallez le montage de brûleur Bordure plaquéeAttachez le linteau en métal et les équerres Préparez les dimensions de encadrementLinteau en métal Dégrossi Ouvrez le Cabinet Dégrossi parInstallez larmature en acier Installez les portes si cest appropriéInstallez le montage de corps sur larmature Attachez les supportsCouche 2 À une seule couche du petit quartz Installation des médias de brûlureCouche 1 Ponce Couche 3 À une seule couche de 14 morceaux de grand quartzAccomplissez le raccordement de gaz Cylindre-gas de propane liquideDirectives pour le revêtement et les finitions Quelle est la durée de cette couverture ? Qu’est-ce qui est couvert ?Quel est l’engagement de Rinnai ? Limitation des garanties implicites Rinnai Corporation ROF4500 Rinnai Corporation ROF4500 Rinnai’s other fine products