DIRECT-VENT FIREPLACE

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Pilot will not light

1.

No gas supply, or shutoff valve is OFF

1.

Check to see if you have gas supply

 

2.

Air in gas line

2.

Hold control valve in the PILOT position

 

 

 

 

for 2 to 3 minutes to purge air. If you smell

 

 

 

 

gas stop and wait for a few minutes before

 

 

 

 

trying to light the fireplace

 

3.

Construction debris clogging pilot orifice

3.

Remove debris and dirt, inspect and

 

 

 

 

clean any other possible obstructions

 

4.

Low gas pressure

4.

Contact your gas supplier

 

5.

Control valve knob is not on the PILOT

5.

Refer to section on pilot lighting

 

 

position

 

 

 

6.

Kinked pilot line

6.

Have a qualified technician replace pi-

 

 

 

 

lot line

 

7.

Bad valve

7.

Replace control valve (see Replacement

 

 

 

 

Parts, page 35)

 

8.

Bad thermocouple or loose connection

8.

Tighten thermocouple or replace

 

 

 

 

 

No gas to burner, although wall switch and

1.

Wall switch wires defective

1.

Check electrical connections

valve are set to the ON position

 

 

 

 

 

 

 

 

 

Frequent pilot outage

1. Pilot flame may be too low, causing

 

safety pilot to “drop out”

1.Clean and adjust pilot flame for maximum flame impingement on thermopile

Burner goes off after a short time

1.

Venting recirculation problem

1.

Have a qualified technician check vent-

 

 

 

 

ing system for leaks or obstructions.

 

 

 

 

Have a qualified technician measure the

 

 

 

 

pilot’s millivoltage

 

 

 

 

 

Burner does not light after pilot is lit

1.

Burner orifice clogged

1.

Clean burner (see Cleaning and

 

 

 

 

Maintenance, page 28) or replace burner

 

 

 

 

orifice

 

2.

Inlet gas pressure is too low

2.

Contact local propane/LP or natural gas

 

 

 

 

company

 

3.

Thermopile leads disconnected or im-

3.

Reconnect leads (see Wiring Diagram,

 

 

properly connected

 

page 35)

 

4.

Thermopile is defective

4.

Replace thermopile

www.desatech.com

32

106497

Image 32
Contents OWNER’S Operation and Installation Manual For Your SafetyCheck Local Codes Prior to Installation MBDV37 and MBDV41Safety Information Product Features Local CodesGlossary Terms Product IdentificationPRE-INSTALLATION Preparation ClearancesLocation and Space Requirements Framing and FinishingPRE-INSTALLATION Preparation General Venting Location of Vent TerminationGeneral Venting Installation Planning Venting InstallationInstallation Precautions Installation for Horizontal Termination Installing Vent System in a ChaseVent Opening Requirements Horizontal Termination Configurations Horizontal VentingVenting with Two 90 Elbows Installation for Vertical Termination Flat Ceiling InstallationCathedral Ceiling Installation Connect a section of pipe and extend up through the holeVertical Termination Configurations Venting with One 90 ElbowVertical Rigid Venting Configuration Using Two 90 Elbows Vertical VentingHigh Altitude Installation Parts Lists for Venting Kits and ComponentsVanguard Rigid Venting Vanguard Flexible VentingFireplace Installation Electrical Hookup for Blower AccessoryCheck GAS Type Number Description Available from Desa InternationalBlower Assembly and Operation Installing GA3700 BlowerSome Models Have Blower Assembly Preinstalled Open lower louver panel or remove for easier accessInstalling Receiver Wall Switch InstallationWireless HAND-HELD Remote Control Ghrc Series Installation Installing GAS Piping to Fireplace Location Installation Items NeededConnecting Fireplace to GAS Supply GAS Supply TestingInstallation Items Needed Pressure Testing Gas Supply Piping SystemPressure Testing Fireplace Gas Connections Close equipment shutoff valve see Fig- ureREMOVING/REPLACING Glass Door Removing/Replacing Glass DoorReplace glass door see Installing Optional Brick Liner D8037A/D8041Tighten all bracket screws Installing LOGS, Lava Rock and Glowing Embers Fireplace Models MBDV37 and MBDV41Operating Guidelines and Maintenance Instructions To Appliance For Your Safety Read Before Lighting Manual Lighting ProcedureOperating Fireplace Lighting To Turn OFF GASPilot Assembly Inspecting BurnersRemote Operation Operating BlowerCleaning and Maintenance Glass DoorPilot and Burners LogsBefore YOU Begin Main Burner Orifice and Pilot OrificeGAS Control Valve Conversion Final PreparationTroubleshooting Observed Problem Possible CauseTrying to light the fireplace Parts,Pilot’s millivoltage OrificeDelayed ignition burner Manifold pressure is too low Burner is litPane/LP or natural gas company Glass soots Flame impingement on logsGas leak. See Warning statement AboveReplacement Parts Wiring Diagram Technical ServiceService Hints SpecificationsIllustrated Parts Breakdown MBDV37 MBDV41Parts List DIRECT-VENT Fireplace MBDV37 MBDV41Accessories Wall Mount ON/OFF Switch KIT GWMS2Cleaning KIT GCK Brass Louver KIT106497 Warranty Information