Vanguard Managed Solutions installation manual Parts List, DIRECT-VENT Fireplace MBDV37 MBDV41

Page 37

OWNER’S MANUAL

PARTS LIST

DIRECT-VENT FIREPLACE

MBDV37

MBDV41

This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 31 of this manual.

KEY

 

 

 

NO.

PART NUMBER

DESCRIPTION

QTY.

 

 

 

 

1

104547-02

Top Outer Casing-37"

1

 

104547-03

Top Outer Casing-41"

1

2

104474-02

Outer Casing-37"

1

 

104474-03

Outer Casing-41"

1

3

104548-02

Bottom Outer Casing-37"

1

 

104548-01

Bottom Outer Casing-41"

1

4

104479-12BR

Firebox Assembly-37"

1

 

104479-11BR

Firebox Assembly-41"

1

5

M11084-26

Screw, Hex

52

6

M11084-46

Screw, Hex

8

7

102455-04

Louver, Extruded-37"

2

 

102455-03

Louver, Extruded-41"

2

8

104443-01

Firebox Support, Right

1

9

104486-01

Firebox Support, Left

1

10

104482-01

Switch Bracket

1

11

104483-01

Floor Mounting Bracket

2

12

104491-01

Relief Cover

1

13

104518-01

Relief Cover Gasket

1

14

104527-01

Relief Spring

2

15

104528-01

Relief Washer

2

16

104537-01

Valve Bracket

1

17

104496-03

SIT Valve, Convertible

1

18

104497-01

SIT Pilot, Convertible

1

19

104498-01

Thermocouple

1

20

104499-01

Thermopile

1

21

104500-01

Ignitor

1

22

104501-01

Ignitor Bracket

1

23

104502-01

Ignitor Screw

1

24

104503-01

Ignitor Wire

1

25

104504-03

Burner w/ Air Shutter

1

26

104506-01

Orifice - 37" (Natural)

1

 

104506-03

Orifice - 41" (Natural)

1

27

104507-01

Brass Elbow

1

28

104508-01

Brass Fitting

2

29

104509-01

Aluminum Tubing Assy

1

30

104510-01

Pilot Tubing Assy

1

31

101628-04

Flexible Connector

1

32

103823-02

Remote Set

1

33

GA3700

Blower Assembly

1

 

 

w/ Speed Control

 

34

107165-01

Log Set - 37"

1

 

107164-01

Log Set - 41"

1

 

 

 

 

KEY

 

 

 

 

 

 

NO.

PART NUMBER

DESCRIPTION

QTY.

 

 

 

 

34-1

107344-02

Rear Log - 37"

1

 

107344-01

Rear Log - 41"

1

34-2

107345-02

Front Log - 37"

1

 

107345-01

Front Log - 41"

1

34-3

107346-01

Crossover Log - 37" & 41"

1

34-4

107347-02

Log Piece - 37"

1

 

107347-01

Log Piece - 41"

1

34-5

107348-01

Log, Top Twig - 37" & 41"

1

35

M10908-2

Screw

6

36

M12461-73

Screw

3

37

H5C4-20B

Bolt

2

38

NTC-4C

Locknut

2

39

M12461-26

Screw

4

40

104555-02CJ

Grate Assembly - 37"

1

 

104555-01CJ

Grate Assembly - 41"

1

41

105775-03

Glass Door Assy - 37"

1

 

105775-01

Glass Door Assy - 41"

1

42

104381-01

Fastener, Ratchet

2

43

104576-02CK

Front Assembly - 37"

1

 

104576-03CK

Front Assembly - 41"

 

44

104615-02

Insulation - 37"

1

 

105628-01

Insulation - 41"

1

45

104313-01

Hinge, Pin

1

46

104313-02

Hinge, Pin

1

47

104954-01

Screw

3

48

104963-01

Washer

3

49

104955-01

Nut

3

50

103769-01

Duplex Outlet

1

51

104602-01

Duplex Outlet Cover

1

52

105325-01

Burner Baffle

1

 

 

 

 

 

PARTS AVAILABLE - NOT SHOWN

 

 

 

 

 

 

GA6060

Lava Rock

1

 

104529-01

Ember Material

1

 

104512-01

Ball Valve

1

 

106040-02

Pilot Orifice

1

 

 

Propane/LP Conversion

 

 

104506-02

Main Burner Orifice (#55)

1

 

 

37" Propane/LP Conv.

 

 

104506-04

Main Burner Orifice (#54)

1

 

 

41" Propane/LP Conv.

 

 

 

 

 

106497

37

Image 37
Contents For Your Safety OWNER’S Operation and Installation ManualCheck Local Codes Prior to Installation MBDV37 and MBDV41Safety Information Local Codes Product FeaturesGlossary Terms Product IdentificationClearances PRE-INSTALLATION PreparationLocation and Space Requirements Framing and FinishingLocation of Vent Termination PRE-INSTALLATION Preparation General VentingGeneral Venting Installation Precautions Venting InstallationInstallation Planning Installing Vent System in a Chase Installation for Horizontal TerminationVent Opening Requirements Horizontal Venting Horizontal Termination ConfigurationsVenting with Two 90 Elbows Flat Ceiling Installation Installation for Vertical TerminationCathedral Ceiling Installation Connect a section of pipe and extend up through the holeVenting with One 90 Elbow Vertical Termination ConfigurationsVertical Venting Vertical Rigid Venting Configuration Using Two 90 ElbowsParts Lists for Venting Kits and Components High Altitude InstallationVanguard Rigid Venting Vanguard Flexible VentingElectrical Hookup for Blower Accessory Fireplace InstallationCheck GAS Type Number Description Available from Desa InternationalInstalling GA3700 Blower Blower Assembly and OperationSome Models Have Blower Assembly Preinstalled Open lower louver panel or remove for easier accessWireless HAND-HELD Remote Control Ghrc Series Installation Wall Switch InstallationInstalling Receiver Installation Items Needed Installing GAS Piping to Fireplace LocationGAS Supply Testing Connecting Fireplace to GAS SupplyInstallation Items Needed Pressure Testing Gas Supply Piping SystemClose equipment shutoff valve see Fig- ure Pressure Testing Fireplace Gas ConnectionsRemoving/Replacing Glass Door REMOVING/REPLACING Glass DoorTighten all bracket screws Installing Optional Brick Liner D8037A/D8041Replace glass door see Fireplace Models MBDV37 and MBDV41 Installing LOGS, Lava Rock and Glowing EmbersOperating Guidelines and Maintenance Instructions Manual Lighting Procedure To Appliance For Your Safety Read Before LightingOperating Fireplace Lighting To Turn OFF GASInspecting Burners Pilot AssemblyRemote Operation Operating BlowerGlass Door Cleaning and MaintenancePilot and Burners LogsMain Burner Orifice and Pilot Orifice Before YOU BeginFinal Preparation GAS Control Valve ConversionObserved Problem Possible Cause TroubleshootingParts, Trying to light the fireplacePilot’s millivoltage OrificeBurner is lit Delayed ignition burner Manifold pressure is too lowPane/LP or natural gas company Glass soots Flame impingement on logsAbove Gas leak. See Warning statementTechnical Service Replacement Parts Wiring DiagramService Hints SpecificationsMBDV37 MBDV41 Illustrated Parts BreakdownDIRECT-VENT Fireplace MBDV37 MBDV41 Parts ListWall Mount ON/OFF Switch KIT GWMS2 AccessoriesCleaning KIT GCK Brass Louver KIT106497 Warranty Information