WARNING: This conversion kit must be installed by a quali- fied service agency in accordance with the manufacturer instruc- tions and all applicable codes and requirements of the author- ity having jurisdiction. If the in- formation in these instructions is not followed exactly, a fire, ex- plosion, or production of carbon monoxide may result causing property damage, personal injury, or loss of life. The qualified ser- vice agency is responsible for the proper installation of this kit. The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer’s instructions sup- plied with the kit.

BEFORE YOU BEGIN

The conversion parts are packaged with the fireplace. Please check the contents before beginning this conversion. Each model in- cludes a brass main burner orifice and a smaller sized pilot orifice (see Figure 60).

Before proceeding, make sure the gas con- trol valve is in the “OFF” position, all elec- trical power to the appliance is OFF, and the appliance is cool to the touch.

Propane/LP

Main Burner

Orifice (18mm

Hex)

Note:

For Model MBDV37 - #55 Drill Size (Stamped with #132 for Identification)

For Model MBDV41 - #54 Drill Size (Stamped with #139 for Identification)

Propane/LP

Pilot Orifice

Note: The pilot orifice has the number 30 stamped on it for identification purposes (Both Models).

Figure 60 - Main Burner Orifice and Pilot Orifice

BURNER AIR SHUTTER ADJUSTMENT, MAIN BURNER ORIFICE, AND PILOT ORIFICE CONVERSION

1.Remove the upper louver panel and glass door (see Removing/Replacing Glass Door, page 22).

2.Carefully remove the log set and em- ber material from around the burner and place them outside the fireplace (see Installing Logs, Lava Rock and Glow- ing Embers, page 24).

3.Open lower louver panel. This allows access below firebox to gas line con- nections and gas control valve.

4.Disconnect flare fitting connected to the brass elbow inside the bottom control compartment area. Use a 3/4" open end wrench on the flare fitting (see Figure 61).

5.Turn brass elbow and main burner ori- fice counterclockwise to remove from burner. The orifice is threaded into the burner inlet. The elbow may have a slight resistance since the orifice has been sealed with RTV silicone. Use a 7/8" open end wrench or channel lock pliers for elbow and orifice removal.

6.Remove existing main burner orifice from brass elbow and replace with main burner orifice supplied with the fire- place. Note: The new main burner ori- fice for propane/LP will have the num- ber 132 (Model MBDV37 only) or the number 139 (Model MBDV41 only) stamped on it for identification pur- poses. Apply a small amount of thread sealant to the orifice before tightening (see Figure 62, page 30). Sealant must be resistant to Propane/LP gas.

Burner

5/16" hex

 

 

Mounting Screw

Fireplace

Air Shutter Screw

Floor

 

 

Air Shutter

 

(Shown in

 

FULLY OPEN

 

Position)

 

RTV Silicone

 

Main Burner

 

Orifice

 

Brass Elbow

Aluminum Tubing

Flare Fitting

Figure 61 - Removing/Replacing Main Burner Orifice, Brass Elbow, and Alumi- num Tubing

Continued

106497

29

Image 29
Contents For Your Safety OWNER’S Operation and Installation ManualCheck Local Codes Prior to Installation MBDV37 and MBDV41Safety Information Local Codes Product FeaturesGlossary Terms Product IdentificationClearances PRE-INSTALLATION PreparationLocation and Space Requirements Framing and FinishingLocation of Vent Termination PRE-INSTALLATION Preparation General VentingGeneral Venting Installation Planning Venting InstallationInstallation Precautions Installing Vent System in a Chase Installation for Horizontal TerminationVent Opening Requirements Horizontal Venting Horizontal Termination ConfigurationsVenting with Two 90 Elbows Flat Ceiling Installation Installation for Vertical TerminationCathedral Ceiling Installation Connect a section of pipe and extend up through the holeVenting with One 90 Elbow Vertical Termination ConfigurationsVertical Venting Vertical Rigid Venting Configuration Using Two 90 ElbowsParts Lists for Venting Kits and Components High Altitude InstallationVanguard Rigid Venting Vanguard Flexible VentingElectrical Hookup for Blower Accessory Fireplace InstallationCheck GAS Type Number Description Available from Desa InternationalInstalling GA3700 Blower Blower Assembly and OperationSome Models Have Blower Assembly Preinstalled Open lower louver panel or remove for easier accessInstalling Receiver Wall Switch InstallationWireless HAND-HELD Remote Control Ghrc Series Installation Installation Items Needed Installing GAS Piping to Fireplace LocationGAS Supply Testing Connecting Fireplace to GAS SupplyInstallation Items Needed Pressure Testing Gas Supply Piping SystemClose equipment shutoff valve see Fig- ure Pressure Testing Fireplace Gas ConnectionsRemoving/Replacing Glass Door REMOVING/REPLACING Glass DoorReplace glass door see Installing Optional Brick Liner D8037A/D8041Tighten all bracket screws Fireplace Models MBDV37 and MBDV41 Installing LOGS, Lava Rock and Glowing EmbersOperating Guidelines and Maintenance Instructions Manual Lighting Procedure To Appliance For Your Safety Read Before LightingOperating Fireplace Lighting To Turn OFF GASInspecting Burners Pilot AssemblyRemote Operation Operating BlowerGlass Door Cleaning and MaintenancePilot and Burners LogsMain Burner Orifice and Pilot Orifice Before YOU BeginFinal Preparation GAS Control Valve ConversionObserved Problem Possible Cause TroubleshootingParts, Trying to light the fireplacePilot’s millivoltage OrificeBurner is lit Delayed ignition burner Manifold pressure is too lowPane/LP or natural gas company Glass soots Flame impingement on logsAbove Gas leak. See Warning statementTechnical Service Replacement Parts Wiring DiagramService Hints SpecificationsMBDV37 MBDV41 Illustrated Parts BreakdownDIRECT-VENT Fireplace MBDV37 MBDV41 Parts ListWall Mount ON/OFF Switch KIT GWMS2 AccessoriesCleaning KIT GCK Brass Louver KIT106497 Warranty Information