Vanguard Managed Solutions MBDV41 installation manual OWNER’S Operation and Installation Manual

Page 1

®

DIRECT-VENT FIREPLACE

OWNER’S OPERATION AND INSTALLATION MANUAL

This fireplace meets the construction and safety standards of H.U.D. for application in mobile homes when installed according to these instructions.

This appliance is

shipped ready for natural

gas installation. The

propane/LP conversion

parts are included.

MBDV37 AND MBDV41

FOR YOUR SAFETY

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS :

Do not try to light any appliance.

Do not touch any electrical switch;

Do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

CHECK LOCAL CODES PRIOR TO INSTALLATION

WARNING: If the information in these instructions is not followed exactly, a fire or explosion may re- sult causing property damage, per- sonal injury, or loss of life.

WARNING: Improper installation, adjustment, alteration, service, or maintenance to this appliance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency, or the gas supplier.

WARNING: This direct-vent gas fire- place series is intended for use with Natural or Propane/LP gas only. Do not attempt to burn any solid fuels in these appliances.

This appliance may be installed as an OEM installation in a manufactured (mobile) home and must be installed in accordance with the manufacturer's instructions and the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 in the United States or the Mobile Home Standard, CAN/CSA Z240 MH Series, in Canada.

This appliance is only for use with the type of gas indicated on the rating plate. A conversion kit is supplied with the appliance.

Save this manual for future reference.

Image 1
Contents For Your Safety OWNER’S Operation and Installation ManualCheck Local Codes Prior to Installation MBDV37 and MBDV41Safety Information Local Codes Product FeaturesGlossary Terms Product IdentificationClearances PRE-INSTALLATION PreparationLocation and Space Requirements Framing and FinishingLocation of Vent Termination PRE-INSTALLATION Preparation General VentingGeneral Venting Installation Precautions Venting InstallationInstallation Planning Installing Vent System in a Chase Installation for Horizontal TerminationVent Opening Requirements Horizontal Venting Horizontal Termination ConfigurationsVenting with Two 90 Elbows Flat Ceiling Installation Installation for Vertical TerminationCathedral Ceiling Installation Connect a section of pipe and extend up through the holeVenting with One 90 Elbow Vertical Termination ConfigurationsVertical Venting Vertical Rigid Venting Configuration Using Two 90 ElbowsParts Lists for Venting Kits and Components High Altitude InstallationVanguard Rigid Venting Vanguard Flexible VentingElectrical Hookup for Blower Accessory Fireplace InstallationCheck GAS Type Number Description Available from Desa InternationalInstalling GA3700 Blower Blower Assembly and OperationSome Models Have Blower Assembly Preinstalled Open lower louver panel or remove for easier accessWireless HAND-HELD Remote Control Ghrc Series Installation Wall Switch InstallationInstalling Receiver Installation Items Needed Installing GAS Piping to Fireplace LocationGAS Supply Testing Connecting Fireplace to GAS SupplyInstallation Items Needed Pressure Testing Gas Supply Piping SystemClose equipment shutoff valve see Fig- ure Pressure Testing Fireplace Gas ConnectionsRemoving/Replacing Glass Door REMOVING/REPLACING Glass DoorTighten all bracket screws Installing Optional Brick Liner D8037A/D8041Replace glass door see Fireplace Models MBDV37 and MBDV41 Installing LOGS, Lava Rock and Glowing EmbersOperating Guidelines and Maintenance Instructions Manual Lighting Procedure To Appliance For Your Safety Read Before LightingOperating Fireplace Lighting To Turn OFF GASInspecting Burners Pilot AssemblyRemote Operation Operating BlowerGlass Door Cleaning and MaintenancePilot and Burners LogsMain Burner Orifice and Pilot Orifice Before YOU BeginFinal Preparation GAS Control Valve ConversionObserved Problem Possible Cause TroubleshootingParts, Trying to light the fireplacePilot’s millivoltage OrificeBurner is lit Delayed ignition burner Manifold pressure is too lowPane/LP or natural gas company Glass soots Flame impingement on logsAbove Gas leak. See Warning statementTechnical Service Replacement Parts Wiring DiagramService Hints SpecificationsMBDV37 MBDV41 Illustrated Parts BreakdownDIRECT-VENT Fireplace MBDV37 MBDV41 Parts ListWall Mount ON/OFF Switch KIT GWMS2 AccessoriesCleaning KIT GCK Brass Louver KIT106497 Warranty Information