Vanguard Managed Solutions MBDV37, MBDV41 Wall Switch Installation, Installing Receiver

Page 18

®

DIRECT-VENT FIREPLACE

FIREPLACE INSTALLATION

Continued

WALL SWITCH INSTALLATION

Since the fireplaces use a valve that operates on millivolt current generated by the pilot, a wall switch (not included) may be used to activate the gas control valve without the use of normal household electricity. A hand- held, ON/OFF remote control is standard with this unit. Wall switch is optional. If the wall switch is installed, the hand-held, ON/ OFF remote cannot be used.

1. To remove the louvers, simultaneously

pull both top end spring latches towards

Note: This unit does not have a HI/LOW feature

Gas Valve

To Thermopile

 

 

 

O

 

 

 

IL

T

 

 

 

P

 

 

 

N

16AI

 

 

 

O

 

 

O

T

 

 

TH

 

 

7

I

 

L

 

 

 

P

 

 

 

 

FFO

 

 

TP

 

E

A

 

TPTH

 

 

 

Route Millivolt Wires (Supplied)

(Back View)

Through Gas Line Conduit Sleeve

 

Figure 35 - Wall Switch Wiring Diagram

Note: If any of the original wire supplied must be replaced, use type 18 AWG-105 degree C (25 feet length MAXIMUM) or equivalent.

the center of the appliance until they

are disengaged from locating holes.

NOTICE: Only use alkaline bat- teries (not included, requires 2).

9-Volt Battery

Repeat for bottom end spring latches

and pull outward. Reverse the proce-

dure to install louvers back onto the

appliance (see Figure 34).

Installing Receiver

Note: Receiver is preinstalled.

Battery Clip

Terminal Wires

Receiver

2. Connect the 18 ga. wires from wall

switch (not included) to the gas con-

trol valve and microswitch, as shown

in Figure 35.

WARNING: Do not wire remote wall switch to main power supply (Standard120vhouseholdcurrent).

Glass

Locating

Holes

 

1.

Remove access panel from lower front

 

face of firebox. Lift straight up on ac-

 

cess panel until it stops. Pull bottom of

 

access panel forward, then down.

2.

Disconnect wall switch wires from TH

 

and TPTH terminals on control valve

 

(see Figure 35).

3.

Install remote receiver unit onto mount-

 

ing bracket using the two plastic mount-

 

ing clips (see Figure 36).

4.

Connect wires to control valve. Con-

 

nect white wire to terminal TH. Con-

 

nect red wire to terminal TPTH.

5.

Locate the battery clip mounted on the

 

back of the receiver (see Figure 37).

Figure 37 - Installing Battery in Receiver

Installing 9-Volt Alkaline Battery in Hand-Held Remote Control Unit

1.Remove battery cover on back of re- mote control unit.

2.Attach terminal wires to the battery (not included). Place battery into the battery housing.

3.Replace battery cover onto remote con- trol unit.

Battery

Cover

Remote

Spring

Latch

Figure 34 - Removing Louver

WIRELESS HAND-HELD REMOTE CONTROL (GHRC SERIES) INSTALLATION

Note: If using the wireless hand-held re- mote control, the wall switch is no longer operational.

6.

Slide 9-volt battery (not included)

 

through the clip.

7.

Attach the terminal wires to the battery

 

(see Figure 37).

Plastic

ReceiverMounting

Clips

Mounting

Bracket

Figure 36 - Installing Remote Receiver (Shown from Rear of Mounting Bracket)

TerminalControl Unit Wires

9-Volt Battery

Battery

Housing

Figure 38 - Installing Battery in Hand- Held Remote Control Unit

18

106497

Image 18
Contents Check Local Codes Prior to Installation OWNER’S Operation and Installation ManualFor Your Safety MBDV37 and MBDV41Safety Information Glossary Terms Product FeaturesLocal Codes Product IdentificationLocation and Space Requirements PRE-INSTALLATION PreparationClearances Framing and FinishingPRE-INSTALLATION Preparation General Venting Location of Vent TerminationGeneral Venting Venting Installation Installation PrecautionsInstallation Planning Installation for Horizontal Termination Installing Vent System in a ChaseVent Opening Requirements Horizontal Termination Configurations Horizontal VentingVenting with Two 90 Elbows Cathedral Ceiling Installation Installation for Vertical TerminationFlat Ceiling Installation Connect a section of pipe and extend up through the holeVertical Termination Configurations Venting with One 90 ElbowVertical Rigid Venting Configuration Using Two 90 Elbows Vertical VentingVanguard Rigid Venting High Altitude InstallationParts Lists for Venting Kits and Components Vanguard Flexible VentingCheck GAS Type Fireplace InstallationElectrical Hookup for Blower Accessory Number Description Available from Desa InternationalSome Models Have Blower Assembly Preinstalled Blower Assembly and OperationInstalling GA3700 Blower Open lower louver panel or remove for easier accessWall Switch Installation Wireless HAND-HELD Remote Control Ghrc Series InstallationInstalling Receiver Installing GAS Piping to Fireplace Location Installation Items NeededInstallation Items Needed Connecting Fireplace to GAS SupplyGAS Supply Testing Pressure Testing Gas Supply Piping SystemPressure Testing Fireplace Gas Connections Close equipment shutoff valve see Fig- ureREMOVING/REPLACING Glass Door Removing/Replacing Glass DoorInstalling Optional Brick Liner D8037A/D8041 Tighten all bracket screwsReplace glass door see Installing LOGS, Lava Rock and Glowing Embers Fireplace Models MBDV37 and MBDV41Operating Guidelines and Maintenance Instructions Operating Fireplace To Appliance For Your Safety Read Before LightingManual Lighting Procedure Lighting To Turn OFF GASRemote Operation Pilot AssemblyInspecting Burners Operating BlowerPilot and Burners Cleaning and MaintenanceGlass Door LogsBefore YOU Begin Main Burner Orifice and Pilot OrificeGAS Control Valve Conversion Final PreparationTroubleshooting Observed Problem Possible CausePilot’s millivoltage Trying to light the fireplaceParts, OrificePane/LP or natural gas company Delayed ignition burner Manifold pressure is too lowBurner is lit Glass soots Flame impingement on logsGas leak. See Warning statement AboveService Hints Replacement Parts Wiring DiagramTechnical Service SpecificationsIllustrated Parts Breakdown MBDV37 MBDV41Parts List DIRECT-VENT Fireplace MBDV37 MBDV41Cleaning KIT GCK AccessoriesWall Mount ON/OFF Switch KIT GWMS2 Brass Louver KIT106497 Warranty Information