DIRECT-VENT FIREPLACE
FIREPLACE INSTALLATION
Continued
WALL SWITCH INSTALLATION
Since the fireplaces use a valve that operates on millivolt current generated by the pilot, a wall switch (not included) may be used to activate the gas control valve without the use of normal household electricity. A hand- held, ON/OFF remote control is standard with this unit. Wall switch is optional. If the wall switch is installed, the
1. To remove the louvers, simultaneously |
pull both top end spring latches towards |
Note: This unit does not have a HI/LOW feature
Gas Valve | To Thermopile |
|
|
| O |
| |
|
| IL | T |
|
|
| P |
|
|
| N | 16AI |
|
|
| O |
|
| |
O | T |
|
| TH |
|
| 7 | ||
I |
| |||
L |
|
|
| |
P |
|
|
| |
| FFO |
|
| TP |
| E | A |
| TPTH |
|
|
|
Route Millivolt Wires (Supplied) | (Back View) | |
Through Gas Line Conduit Sleeve | ||
|
Figure 35 - Wall Switch Wiring Diagram
Note: If any of the original wire supplied must be replaced, use type 18
the center of the appliance until they |
are disengaged from locating holes. |
NOTICE: Only use alkaline bat- teries (not included, requires 2).
Repeat for bottom end spring latches |
and pull outward. Reverse the proce- |
dure to install louvers back onto the |
appliance (see Figure 34). |
Installing Receiver
Note: Receiver is preinstalled.
Battery Clip
Terminal Wires
Receiver
2. Connect the 18 ga. wires from wall |
switch (not included) to the gas con- |
trol valve and microswitch, as shown |
in Figure 35. |
WARNING: Do not wire remote wall switch to main power supply (Standard120vhouseholdcurrent).
Glass | Locating | |
Holes | ||
|
1. | Remove access panel from lower front |
| face of firebox. Lift straight up on ac- |
| cess panel until it stops. Pull bottom of |
| access panel forward, then down. |
2. | Disconnect wall switch wires from TH |
| and TPTH terminals on control valve |
| (see Figure 35). |
3. | Install remote receiver unit onto mount- |
| ing bracket using the two plastic mount- |
| ing clips (see Figure 36). |
4. | Connect wires to control valve. Con- |
| nect white wire to terminal TH. Con- |
| nect red wire to terminal TPTH. |
5. | Locate the battery clip mounted on the |
| back of the receiver (see Figure 37). |
Figure 37 - Installing Battery in Receiver
Installing
1.Remove battery cover on back of re- mote control unit.
2.Attach terminal wires to the battery (not included). Place battery into the battery housing.
3.Replace battery cover onto remote con- trol unit.
Battery
Cover
Remote
Spring
Latch
Figure 34 - Removing Louver
WIRELESS HAND-HELD REMOTE CONTROL (GHRC SERIES) INSTALLATION
Note: If using the wireless
6. | Slide |
| through the clip. |
7. | Attach the terminal wires to the battery |
| (see Figure 37). |
Plastic
ReceiverMounting
Clips
Mounting
Bracket
Figure 36 - Installing Remote Receiver (Shown from Rear of Mounting Bracket)
TerminalControl Unit Wires
Battery
Housing
Figure 38 - Installing Battery in Hand- Held Remote Control Unit
18 | 106497 |