Napoleon Fireplaces B36DFP, B36DFN Horizontal Termination, Definitions, Elbow Vent Length Values

Page 10

10

DEFINITIONS

for the following symbols used in the venting calcula- tions and examples are:

>- greater than

>- equal to or greater than < - less than

< - equal to or less than

HT - total of both horizontal vent lengths (HR) and off- sets (HO) in feet

HR - combined horizontal vent lengths in feet

HO - offset factor: .03(total degrees of offset - 135°*) in feet

VT - combined vertical vent lengths in feet

ELBOW VENT LENGTH VALUES

 

feet

inches

0.03

0.5

15°

0.45

6.0

30°

0.9

11.0

45°*

1.35

16.0

90°*

2.7

32.0

*the first 45º and 90° offset has a zero value and is shown in the formula as -45°and -90ºrespectively or -135ºwhen combined.

HORIZONTAL TERMINATION

when (HT) < (VT)

Simple venting configuration (only one 45º and 90° elbow)

90°

FIGURE 5

For vent configurations requiring more than one 45º and 90° elbow, the following formulas apply:

Formula 1: HT

< VT

 

 

 

Formula 2: HT

+ VT

< 40 feet

 

Example 1:

 

 

 

 

 

 

 

 

90°

 

H2

 

 

 

 

 

 

 

FIGURE 6V1

45º45º

H1 90°

REQUIRED

VERTICAL RISEINFEET (VT)

CALCULATED HORIZONTAL VENT RUN PLUS OFFSETS IN FEET (HT)

The shaded area within the lines represents acceptable values for HT and VT .

V1

=

8 ft

VT

= V1 = 8 ft

H1

=

2.5 ft

H2

=

2 ft

HR

= H1 + H2 = 2.5 + 2 = 4.5 ft

HO

= .03(one 45º elbow + two 90º elbows - 135º)

=0.3(225-135º) = 2.7ft

HT

= HR + HO = 4.5 + 2.7 = 7.2 ft

HT + VT = 7.2 +8 =15.2ft

Formula 1: HT < VT

7.2< 8

Formula 2: HT + VT < 40 feet

15.2 < 40

Since both formulas are met, this vent configuration is ac- ceptable.

W415-0484 / A / 07.26.06

Image 10
Contents W415-0484 / a What to do if YOU Smell GAS Table of Contents Conditions and Limitations General Information General InstructionsCare of GLASS, and Plated Parts Venting Venting LengthsAIR Terminal Locations Typical Vent Installations Special Vent InstallationsVenting Application Flow Chart Horizontal Termination VerticalDefinitions When HT VTHorizontal Termination Elbow Vent Length ValuesWhen H T V T Simple venting configuration only one 45º and 90 elbowVertical Termination Formula 1 HT 3VT Formula 2 HT + VT 40 feet Example Horizontal Installation Installation Wall and Ceiling ProtectionVertical Installation Using Flexible Vent Components Horizontal AIR Terminal InstallationGAS Installation Restricting Vertical VentsFraming Mobile Home InstallationConversion Kits Nailing TAB Installation Mantle InstallationDoor Removal & Installation L36 Louvre Installation FinishingCharcoal Embers LOG PlacementLogo Placement Glowing EmbersOptional Blower Installation Qualified StallerOptional FAN Installation GD36 Thermostatic Sensor ControlOperating Instructions Operation / MaintenanceMaintenance Not use any phone in your buildingPilot Burner Adjustment AdjustmentsVenturi Adjustment Replacements Common Replacement PartsCattena Utio Hchaud Trouble Shooting Guide Symptom Problem Test SolutionAfter Taking Pressure READINGS, be Sure to Turn Fireplace Service History W415-0484 / a