Napoleon Fireplaces B36DFN, B36DFP manual General Instructions, General Information

Page 5

GENERAL INSTRUCTIONS

THIS GAS FIREPLACE SHOULD BE INSTALLED AND SERV- ICED BY A QUALIFIED INSTALLER to conform with local codes. In absence of local codes, install the B36DF to the current National Fuel Gas Code, ANSI Z223.1, or the current CAN/CGA B149, Installation Codes.

Installation practices vary from region to region and it is important to know the specifics that apply to your area,

for example: in Massachusetts State:

The fireplace damper must be removed or welded in the open position prior to installation of a fireplace insert or gas log.

A carbon monoxide detector is required in all rooms containing gas fired appliances

The appliance off valve must be a “T” handle gas cock.

The flexible connector must not be longer than 36 inches.

The appliance is not approved for installation in a bedroom or bathroom unless the unit is a direct vent sealed combustion product.

WARNING: This product must be installed by a licensed plumber or gas fitter when installed within the commonwealth of Massachusetts.

Mobile home installation must conform with local codes or in the absence of local codes, install to the current standard for gas equipped mobile housing CAN/CSA ZA240 MH Series in Canada or the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the Fire Safety Criteria for Manufac- tured Home Installations, Sites and Communities Standard ANSI/ NFPA 501A in the United States.

The fireplace and its individual shutoff valve must be discon- nected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). The fireplace must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).

When the fireplace is installed directly on carpeting, vinyl tile or other combustible material other than wood flooring, the fireplace shall be installed on a metal or wood panel extend- ing the full width and depth.

If the optional fan or blower is installed, the junction box must be electrically connected and grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the United States.

GENERAL INFORMATION

FOR YOUR SATISFACTION, THIS FIREPLACE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND QUALITY! Maximum input is 23,000 BTU/hr for natural gas and propane. When the fireplace is installed at elevations above 4,500ft, and in the absence of specific recommendations from the local au- thority having jurisdiction, the certified high altitude input rating shall be reduced at the rate of 4% for each additional 1,000ft.

Maximum output for natural gas and propane is 15,200 BTU/ hr at an efficiency of 66% with the fan on. The maximumA.F.U.E. (annual fuel utilization efficiency) rating is 62% for natural gas and propane.

5

Minimum inlet gas supply pressure is 4.5 inches water col- umn for natural gas and 11 inches water column for propane. Maximum inlet gas pressure is 7 inches water column for natural gas and 13 inches water column for propane. Mani- fold pressure under flow conditions is 3.5 inches water col- umn for natural gas and 10 inches water column for propane.

This fireplace is approved for bathroom, bedroom and bed- sitting room installations and is suitable for mobile home installation.

No external electricity (110 volts or 24 volts) is required for the gas system operation.

Expansion / contraction noises during heating up and cool- ing down cycles are normal and are to be expected.

CARE OF GLASS, AND PLATED PARTS

Do not use abrasive cleaners to clean plated parts. Buff lightly with a clean dry cloth. The B36DF is factory equipped with tempered glass. The glass thickness is 3/16". Use only re- placement glass available from your Napoleon dealer. DO NOT SUBSTITUTE MATERIALS. Clean the glass after the first 10 hours of operation with a recommended gas fireplace glass cleaner. Thereafter clean as required. DO NOT CLEAN GLASS WHEN HOT! If the glass is not kept clean permanent

discolouration and / or blemishes may result.

Use only accessories designed for and listed with

your specific fireplace.

Provide adequate ventilation air. Provide adequate ac- cessibility clearance for servicing and operating the fireplace. Never obstruct the front opening of the fire- place.

For safe and proper operation of the fireplace follow the venting instruction exactly.

In order to avoid the possibility of exposed insulation or vapour barrier coming in contact with the fireplace body, it is recommended that the walls of the fireplace enclo- sure be 'finished', (i.e. drywall/sheetrock) as would any other outside wall of the home. This will ensure that clearance to combustibles is maintained within the cav- ity.

W415-0484 / A / 07.23.06

Image 5
Contents W415-0484 / a What to do if YOU Smell GAS Table of Contents Conditions and Limitations Care of GLASS, and Plated Parts General InstructionsGeneral Information Venting Lengths VentingAIR Terminal Locations Special Vent Installations Typical Vent InstallationsHorizontal Termination Vertical Venting Application Flow ChartHorizontal Termination When HT VTDefinitions Elbow Vent Length ValuesSimple venting configuration only one 45º and 90 elbow When H T V TVertical Termination Formula 1 HT 3VT Formula 2 HT + VT 40 feet Example Vertical Installation Installation Wall and Ceiling ProtectionHorizontal Installation Horizontal AIR Terminal Installation Using Flexible Vent ComponentsRestricting Vertical Vents GAS InstallationConversion Kits Mobile Home InstallationFraming Mantle Installation Nailing TAB InstallationFinishing Door Removal & Installation L36 Louvre InstallationLogo Placement LOG PlacementCharcoal Embers Glowing EmbersQualified Staller Optional Blower InstallationGD36 Thermostatic Sensor Control Optional FAN InstallationMaintenance Operation / MaintenanceOperating Instructions Not use any phone in your buildingVenturi Adjustment AdjustmentsPilot Burner Adjustment Common Replacement Parts ReplacementsCattena Utio Hchaud Symptom Problem Test Solution Trouble Shooting GuideAfter Taking Pressure READINGS, be Sure to Turn Fireplace Service History W415-0484 / a