Napoleon Fireplaces B36DFN, B36DFP manual AIR Terminal Locations

Page 7

7

AIR TERMINAL LOCATIONS

FIGURE 2

 

INSTALLATIONS

 

 

 

 

 

 

CANADIAN

U.S.A.

 

 

 

 

 

A

12 INCHES

12 INCHES

Clearance above grade, veranda porch, deck or balcony.

 

 

 

 

B

12 INCHES

9 INCHES

Clearance to windows or doors that open.

 

 

 

 

C

12 INCHES*

12 INCHES*

Clearance to permanently closed windows.

 

 

 

 

D

18 INCHES**

18 INCHES**

Vertical clearance to ventilated soffit located above the terminal within

a horizontal distance of 2 feet from the centerline of the terminal.

 

 

 

 

E

12 INCHES**

12 INCHES**

Clearance to unventilated soffit.

 

 

 

 

F

0 INCHES

0 INCHES

Clearance to an outside corner wall.

 

 

 

 

 

0 INCHES***

0 INCHES***

Clearance to an inside non-combustible corner wall or protruding

 

non-combustible obstructions (chimney, etc.).

 

 

 

G

 

 

 

2 INCHES***

2 INCHES***

Clearance to an inside combustible corner wall or protruding com-

 

 

bustible obstructions ( vent chase, etc.).

 

 

 

 

 

 

 

H

3 FEET

3 FEET****

Clearance to each side of the centerline extended above the meter

/ regulator assembly to a maximum vertical distance of 15ft.

 

 

 

 

 

 

 

I

3 FEET

3 FEET****

Clearance to a service regulator vent outlet.

 

 

 

 

J

12 INCHES

9 INCHES

Clearance to a non-mechanical air supply inlet to the building or a

combustion air inlet to any other appliance.

 

 

 

 

 

 

 

K

6 FEET

3 FEET†

Clearance to a mechanical air supply inlet.

 

 

 

 

L

7 FEET‡

7 FEET****

Clearance above a paved sidewalk or paved driveway located on

public property unless fitted with a heat shield kit GD-301.

 

 

 

 

 

 

 

 

 

 

 

 

M

12 INCHES††

12 INCHES****

Clearance under a veranda, porch, deck or balcony.

 

 

 

 

N

16 INCHES

16 INCHES

Clearance above the roof.

 

 

 

 

 

 

O

2 FEET†*

2 FEET†*

Clearance from an adjacent wall including neighbouring buildings.

 

 

 

 

 

 

*Recommended to prevent condensation on windows and thermal breakage

**It is recommended to use a heat shield and to maximize the distance to vinyl clad soffits.

***The periscope GD-201 requires a minimum 18 inches clearance from an inside corner.

****This is a recommended distance. For additional requirements check local codes.

Three feet above if within 10 feet horizontally.

A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings.

††Permitted only if the veranda, porch, or deck is fully open on a minimum of two sides beneath the floor.

†* Recommenced to prevent recirculation of exhaust products. For additional requirements check local codes.

W415-0484 / A / 07.23.06

Image 7
Contents W415-0484 / a What to do if YOU Smell GAS Table of Contents Conditions and Limitations General Information General InstructionsCare of GLASS, and Plated Parts Venting Lengths VentingAIR Terminal Locations Special Vent Installations Typical Vent InstallationsHorizontal Termination Vertical Venting Application Flow ChartElbow Vent Length Values When HT VTHorizontal Termination DefinitionsSimple venting configuration only one 45º and 90 elbow When H T V TVertical Termination Formula 1 HT 3VT Formula 2 HT + VT 40 feet Example Horizontal Installation Installation Wall and Ceiling ProtectionVertical Installation Horizontal AIR Terminal Installation Using Flexible Vent ComponentsRestricting Vertical Vents GAS InstallationFraming Mobile Home InstallationConversion Kits Mantle Installation Nailing TAB InstallationFinishing Door Removal & Installation L36 Louvre InstallationGlowing Embers LOG PlacementLogo Placement Charcoal EmbersQualified Staller Optional Blower InstallationGD36 Thermostatic Sensor Control Optional FAN InstallationNot use any phone in your building Operation / MaintenanceMaintenance Operating InstructionsPilot Burner Adjustment AdjustmentsVenturi Adjustment Common Replacement Parts ReplacementsCattena Utio Hchaud Symptom Problem Test Solution Trouble Shooting GuideAfter Taking Pressure READINGS, be Sure to Turn Fireplace Service History W415-0484 / a