Napoleon Fireplaces B36DFP, B36DFN LOG Placement, Charcoal Embers, Glowing Embers, Logo Placement

Page 20

20

LOG PLACEMENT

PHAZERTM logs and glowing embers exclusive to Napoleon Fire- places, provide a unique and realistic glowing effect that is different in every installation. Take the time to carefully po- sition the glowing embers for a maximum glowing effect. Log colours may vary. During the initial use of the fireplace, the colours will become more uniform as colour pigments burn in during the heat activated curing process.

FIGURE 37a-d

3.Place the bottom of the left crossover log (#4) onto the locating stud on the left side of the log support.

The top of the log should rest in the pocket on the rear log.

#1

REARVIEW

#5

4.Position the heel of log #5 into the slot in the centre of the log support. ther end of the log rests in the pocket of the left log.

LOCATOR

#6

TABTAB

1.Place the rear log against the locator, pushing down, until it rests on the base, infront of the tabs.

#2 #3

2.Move the two small logs (#2 & #3) into position, lining up the studs located on the burner with the holes on the bottom of the logs. Ensure that the small logs sit flat on the burner.

#4

5.Place the bottom of the right crossover log (#6) onto the locating stud on the right side of the log support. The top of the log should rest in the pocket provided on the center log (#5).

CHARCOAL EMBERS

Randomly place the charcoal embers along the front and sides of the log support tray in a realistic manner. Fine dust found in the bottom of the bag should not be used.

GLOWING EMBERS

Tear the embers into pieces and place along the front row of ports covering all of the burner area in front of the small logs (#2 & #3). Care should be taken to shred the embers into thin, small irregular pieces as only the exposed edges of the fibre hairs will glow. The ember material will only glow when exposed to direct flame; however, care should be taken to not block the burner ports.

Blocked burner ports can cause an incorrect flame pattern, carbon deposits and delayed ignition. PHAZERTM logs glow when exposed to direct flame. Use only certified "glowing embers" and PHAZERTM logs available from your Napo- leon dealer.

LOGO PLACEMENT

Remove the backing of the

½"

 

 

 

 

logo supplied and place on the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

glass viewing door, as

 

 

 

LOGO

 

 

indicated.

 

 

 

 

½"

 

 

 

 

 

 

 

FIGURE 38

 

W415-0484 / A / 07.26.06

Image 20
Contents W415-0484 / a What to do if YOU Smell GAS Table of Contents Conditions and Limitations Care of GLASS, and Plated Parts General InstructionsGeneral Information Venting Venting LengthsAIR Terminal Locations Typical Vent Installations Special Vent InstallationsVenting Application Flow Chart Horizontal Termination VerticalWhen HT VT Horizontal TerminationDefinitions Elbow Vent Length ValuesWhen H T V T Simple venting configuration only one 45º and 90 elbowVertical Termination Formula 1 HT 3VT Formula 2 HT + VT 40 feet Example Vertical Installation Installation Wall and Ceiling ProtectionHorizontal Installation Using Flexible Vent Components Horizontal AIR Terminal InstallationGAS Installation Restricting Vertical VentsConversion Kits Mobile Home InstallationFraming Nailing TAB Installation Mantle InstallationDoor Removal & Installation L36 Louvre Installation FinishingLOG Placement Logo PlacementCharcoal Embers Glowing EmbersOptional Blower Installation Qualified StallerOptional FAN Installation GD36 Thermostatic Sensor ControlOperation / Maintenance MaintenanceOperating Instructions Not use any phone in your buildingVenturi Adjustment AdjustmentsPilot Burner Adjustment Replacements Common Replacement PartsCattena Utio Hchaud Trouble Shooting Guide Symptom Problem Test SolutionAfter Taking Pressure READINGS, be Sure to Turn Fireplace Service History W415-0484 / a