ELECTRICAL SUPPLY CONNECTION
9WIRING DIAGRAMS
ELECTRICAL SUPPLY CONNECTION
CAUTION: Disconnect the electrical power to the supply circuit before attempting to connect or service this appliance.
Note: If you do not need to relocate the junction box, to connect the electric supply follow steps 8 through 11 only:
1. | Remove the 2 screws and outer cover with strain relief bushing |
| on the right side of the cabinet (see Figure 13). |
2. | Removeinnerretainingscrew onthejunctionboxmountingtab. |
3. | Slide the junction box up until the screw mounting tab is lined |
| up to the notch in the outer cabinet. |
4. | Swing the junction box out and slip the retaining flange out |
| through the slot in the outer cabinet. |
5. | Remove the two screws and outer cover on the left side |
| of the outer cabinet. |
WARNING: This appliance, when installed must be electrically grounded in accordance with local code or in the absence of local code, with the current National Electric Code, ANSI/NFPA 70, or the Canadian Electric Code, CSA C22.1.
WIRING DIAGRAMS
NOTICE:This appliance is equipped with a vent safety shutoff switch which will shut down the appliance in case of a venting problem. Do not bypass the vent safety shutoff switch. If the appliance should shut down, have a qualified installer, service agency, or your gas supplier inspect the vent before operating.
CAUTION: label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
6. Reinsert the junction box retaining flange through the slot now |
on the left side and swing the screw mounting tab back through |
the notch as before. |
PILOT BURNER
MILLIVOLT WIRING DIAGRAM
THERMOPILE
7. | Slide the junction box down till the mounting tab holes line up |
| and replace the inner retaining screw. |
8. | With the junction box cover removed, pull the end of |
| Romex supply line through the universal strain relief bushing |
| on the cover. (see Figure 13). |
9. | Strip back the outer Romex to about 4” and connect the black, |
| white and green wires accordingly using 3 wire nut connectors. |
INCOMING MAIN GAS SUPPLY
| ON |
LO | T |
| |
IP | |
| F FO |
REPLACE FACTORY WIRING WITH 105°C EQUIVALENT OR HIGHER RATING
EXTERNAL WIRING USE ONLY CLASS 2 THERMOSTAT WIRE 18 GA. RED/WHITE
RED
WHITE | HIGH LIMIT |
| SWITCH |
TH | NC |
TP |
|
TH/TP |
|
DO NOT CONNECT TO 120V
10. Tuck the tailing wires into the junction box and replace the |
junction box cover using the 2 remaining screws. |
11. Tighten the adjustment on the universal stran bushing to secure |
the Romex sheathing and complete the supply connection. |
COVER w/J-BOX COVER
STRAIN RELIEF
COVER w/
STRAIN RELIEF
ROMEX
CABLE SCREW - TAB
RETAINER
RECEPTACLE
WALL SWITCH / REMOTE RECEIVER
Figure 14 - Millivolt Ignition Wiring Diagram
HIGH LIMIT |
| IGNITOR |
| PILOT |
SWITCH |
|
| BURNER | |
NC |
|
|
|
|
|
| ORANGE |
|
|
GAS VALVE |
| RED |
|
|
|
|
|
| |
|
| IGNITIONCONTROL MODULE | RED | TRANSFORMER |
EV1 |
| 24VAC | ||
BLACK |
| |||
|
|
|
| |
| BLACK |
|
| WHITE |
| BLACK |
|
| BLACK |
|
|
|
|
EV2
BLUE GROUND
BLUE
GREEN IGNITION MODULE
Figure 13 - Relocating Junction Box Receptacle and
ELECTRONIC IGNITION
WIRING DIAGRAM
120 VAC
Electrical Supply Connection
Figure 15 - Electronic Ignition Wiring Diagram
www.desatech.com |