Desa (V) CB36(N Operating Fireplace, For Your Safety Read Before Lighting, Lighting Instructions

Page 17

OPERATING FIREPLACE - Manual Ignition System

For Your Safety Read Before Lighting

16

Lighting Instructions

To Turn Off Gas To Appliance

Manual Lighting Procedure

OPERATING FIREPLACE

Manual Ignition System

FOR YOUR SAFETY READ

BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing prop- erty, damage, personal injury or loss of life.

If gas control knob does not pop up when released, stop and immediately call your service technician or gas suppier.

If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service techni- cian or gas supplier.

9.Turn on all electric power to fireplace.

10.Turn gas control knob counterclockwise to “ON”.

11.Close lower louver panel.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floorbecause some gas is heavier than air and will settle on the floor.

Gas Control

Regulator Cap

 

Knob

 

ILOT

O

P

F

N

F

 

O

 

Piezo Ignitor

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s Phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service techni- cian to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING

INSTRUCTIONS

1.STOP! Read the safety information above.

2.Open lower louver panel.

3.Turn off all electric power to the fireplace.

4.Push in gas control knob slightly and turn clockwise to “OFF” (see Figure 33).

5.Wait five (5) minutes to clear out any gas. Then smell for. gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information above. If you don’t smell gas go to the next step.

6.The pilot is located by the main burner and should not re- quire accessing for lighting.

7.Turn gas control knob counterclockwise to “PILOT”.

8.Push in gas control knob all the way and hold. Immedi- ately light the pilot by repeatedly depressing the piezo spark ignitor until a flame appears. Continue to hold for about one (1) minute after the pilot is lit. Release gas control knob and it will pop back. Pilot should remain lit. If it goes out, repeat steps 5 through 8.

Figure 33 - Control Valve Millivolt

TO TURN OFF GAS

TO APPLIANCE

1.Open lower louver panel.

2.Set the wall switch to the OFFposition orthe GHRC selector switch (when equipped) to prevent draining the battery.

3.Turn off all electric power to the appliance if service is to be performed.

4.Push in gas control knob slightly and turn clockwise to “OFF”.

5.Close lower louver panel.

Shutting Off Berners Only (pilot stays lit)

You may shut off the burners and keep the pilot lit by doing one of the following:

1.Turn gas control knob clockwise to the PILOT position.

2.Set the wall switch to the OFF position or the HRC selector switch (when equipped) to prevent draining the battery.

MANUAL LIGHTING

PROCEDURE

1.Remove glass door (see Removing/Replaceing Glass Door, page 14).

2.Follow steps 1 through 8 under Lighting Instructions.

3.Depress gas control knob and light pilot with match.

4.Keep gas control knob pressed in for 30 seconds after light- ing pilot. After 30 seconds, release gas control knob. Fol- low steps 10 through 11 under Lighting Instructions.

5.Replace glass door (see Removing/Replacing Glass Door, page 14).

117437-01

www.desatech.com

Image 17
Contents Inch B-VENT Decorative GAS Fireplaces For Your Safety OWNER’S Operation and Installation ManualFor Your Safety What to do if YOU Smell GAS Save this manual for future referencePage Safety Information Table of ContentsLocal Codes Product IdentificationPRE-INSTALLATION Preparation Product FeaturesFraming and Finishing PRE-INSTALATION PreparationClearances Mantel Clearances Unit DimensionsTypical B-Vent Configuration Installation Precautions Venting InstallationChecking for Proper Venting Venting InstallationElectrical Supply Connection Wiring DiagramsElectronic Ignition Wiring Diagram Installing Optional Wall Mount Switch GWMS2 Installing Optional ControlsReceiver Volt Alkaline Battery Terminal Wires Battery Clip Installing Remote ReceiverInstalling GAS Piping to Fireplace High Altitude InstallationGAS Supply and Piping Check GAS TypeNatural From Installation Items NeededTest Pressures In Excess of 1/2 Psig 3.5 kPa Checking GAS ConnectionsTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Equipment Shutoff Open Valve ClosedRemoving Lower Louver Access Panel Hearth Access and AssemblyRemoving Top Louver Trim Panel Removing/Replacing Glass DoorApplying Ember Material Installing Logs and Glowing EmbersManual Lighting Procedure For Your Safety Read Before LightingOperating Fireplace Lighting InstructionsOperating Fireplace Electronic Ignition System Optional Wireless Remote OperationON/OFF Series Model HRC100 Operating Optional GWMS2 ON/OFF Wall Mounted SwitchOptional HAND-HELD Remote Operation AIR Adjustment Setting Pilot AssemblyInspecting Burners Burner Flame PatternGlass Door Cleaning and MaintenancePilot and Burners LogsPilot unit TroubleshootingNeedle, or similar object to Or cycles during operation Gas leak. See Warning statement Ment Parts, Gas leak. See Warning statement at Technical Service Replacement Parts Service HintsSpecifications Parts Under WarrantyIllustrated Parts Breakdown KEY Parts ListVCB36N VCB36NEBurner Assembly for Models VCB36N, VCB36P Description QTY Burner Assembly for Models VCB36NE, VCB36PE KEY VCB36NE VCB36PE Description QTY Remote Control KIT WRC Series AccessoriesOWNER’S Registration Form Industrial Drive Box Bowling Green, KY 117437-01 117437-01 Page Industrial Drive P.O. Box Keep this WarrantyModel Serial No Date Purchased