REPLACEMENT PARTS
SPECIFICATIONS 26
SERVICE HINTS
TECHNICAL SERVICE
REPLACEMENT PARTS | SERVICE HINTS |
Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.
PARTS UNDER WARRANTY
Contact authorized retailers of this product. If they can not supply original replacement part(s), call DESA’s Customer Service De- partment at
When calling DESA, have ready
•your name
•your address
•model and serial numbers of your fireplace
•how fireplace was malfunctioning
•type of gas used (propane/LP or natural gas)
•purchase date
Usually, we will ask you to return the part to the factory.
When Gas Pressure Is Too Low
•pilot will not stay lit
•burners will have delayed ignition
•fireplace will not produce specified heat
•propane/LP gas supply might be low (propane/LP units only)
You may feel your gas pressure is too low. If so, contact your local gas supplier.
TECHNICAL SERVICE
You may have further questions about installation, operation, or troubleshooting. If so, contact DESA’s Customer Service Depart- ment at
You can also visit DESA’s technical service web site at www.desatech.com.
PARTS NOT UNDER WARRANTY
Contact authorized retailers of this product. Ifthey can not supply original replacement part(s), call DESA’s Customer Service De- partment at
When calling DESA, have ready
• model number of your fireplace
• the replacement part number
SPECIFICATIONS
| (V)CB36N | (V)CB36P | (V)CB36NE | (V)CB36PE |
|
|
|
|
|
Max. Input Rating Btu/hr | 18,000 Btu/hr | 18,000 Btu/hr | 18,000 Btu/hr | 18,000 Btu/hr |
|
|
|
|
|
Orifice Size (Main Burner) | #45 DMS (0.082") | #55 DMS (0.052") | #45 DMS (0.082") | #55 DMS (0.052") |
|
|
|
|
|
Gas Type | Natural | Propane/LP | Natural | Propane/LP |
|
|
|
|
|
Ignition | Millivolt | Millivolt | Electronic | Electronic |
|
|
|
|
|
Manifold Pressure | 3.5” w.c. (0.87 kPa) | 10.0” w.c. (2.5 kPa) | 3.5” w.c. (0.87 kPa) | 10.0” w.c. (2.5 kPa) |
|
|
|
|
|
Minimum Inlet Supply Pressure | 5.5” w.c. (1.1 kPa) | 11.0” w.c. (2.7 kPa) | 5.5” w.c. (1.1 kPa) | 11.0” w.c. (2.7 kPa) |
|
|
|
|
|
Dimension, Inches/mm (HxWxD) |
|
|
|
|
Fireplace (Actual size of firebox | 35 ¾"x 36 ¼" x 14 ¾" | 35 ¾"x 36 ¼" x 14 ¾" | 35 ¾"x 36 ¼" x 14 ¾" | 35 ¾"x 36 ¼" x 14 ¾" |
measurements do not include | 908 x 921 x 375 mm | 908 x 921 x 375 mm | 908 x 921 x 375 mm | 908 x 921 x 375 mm |
nailing flanges or standoffs). |
|
|
|
|
Carton | 36 ¾" x 38" x 16 ¼" | 36 ¾" x 38" x 16 ¼" | 36 ¾" x 38" x 16 ¼" | 36 ¾" x 38" x 16 ¼" |
| 933 x 965 x 413 mm | 933 x 965 x 413 mm | 933 x 965 x 413 mm | 933 x 965 x 413 mm |
|
|
|
|
|
Fireplace Weight, lbs/kg | 98 lbs./45kg | 98 lbs./45kg | 102 lbs./47kg | 102 lbs./47kg |
Shipping Weight, lbs/kg | 101 lbs./46kg | 101 lbs./46kg | 105 lbs./48kg | 105 lbs./48kg |
|
|
|
|
|
www.desatech.com |