Desa (V) CB36(N installation manual Product Features, PRE-INSTALLATION Preparation

Page 5

PRODUCT FEATURES

PRE-INSTALLATION PREPARATION 4

Location and Space Requirements

PRODUCT FEATURES

These are a few facts that can help you understand and enjoy your vented decorative fireplace:

The(V)CB36(N,P)(E)seriesofventeddecorativefireplacesmay be recessed into an exterior chase, an interior flush wall enclosure or a framed-in corner installation.

Models (V)CB36(N,P) are equipped with a millivolt gas control system that does not require electricity to operate. A piezo ignitor is provided to light the pilot without using matches or lighters.

Models (V)CB36(NE/PE) are equipped with an electronic ignition system that requires 120VAC to operate. An electrode ignitor automatically lights the pilot flame when the fireplace is turned on.

These fireplaces can accept any approved 4” B-Type venting system and must be terminated vertically through the roof using a listed type vent cap only. See venting instructions on pages # and # for proper venting requirements.

These vented fireplaces require indoor air for combustion and must be installed in a room of sufficient size to provide adequate fresh air forsafeandproperoperation.Theroomintendedforinstallationmust be of sufficient size to meet the requirements for an unconfined space as defined in the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilaton. If sufficient air for combustion is not available a make-up air kit model AK4 may be required to provide outside air to this appliance. Check your local codes as to specific requirements for make-up air.

This fireplace may be installed in any room of the house provided all local codes and these installation instructions are followed.

PRE-INSTALLATION

PREPARATION

LOCATION AND SPACE REQUIREMENTS

Determine the safest and most efficient location for your DESA direct-vent fireplace. Make sure that rafters and wall studs are not in the way of the venting system. Coose a location where the heat output is not affected by drafts, air conditioning ducts, windows or doors. Figure 2 shows some common locations. Be aware of all restrictions and precautions before deciding the exact location for your fireplace and termination cap.

When deciding the location of your fireplace, follow these rules:

• Do not connect this fireplace to a chimney flue servicing a separate solid-fuel burning fireplace or appliance.

Do to high temperatures, do not locate this fireplace in high traf- fic areas, windy or drafty areas, or near furniture or draperies.

Proper clearances must be maintained.

If your fireplace is to be installed directly on carpeting, vinyl tile, or any combustible material other than wood, it must be installed on a metal or wood panel exttending the full width and depth of the fireplace. See Figure 3.

Only trim kits supplied by DESA shall be used in the installation of this fireplace, see Accessories, page 33.

Do not install aftermarket vent dampers. Manual or Auto matic vent dampers are not approved for use with this appliance.

Your fireplace is designed to be used in zero clearance installa- tions. Wall or framing material can be placed directly against any exterior surface on the back, sides, or top of your fireplace, except when clearances are required from flue vent pipe. See Clearances on page 5.

If recessed into a wall, you can avoid extra framing by position- ing your fireplace against an already existing framing member.

A hearth extension is not required with this appliance. If one is installed, it is for austhetic purposes only and does not have to meet standard requirements for hearth extensions.

If you plan on installing a television or entertainment center re- cessed above your fireplace, it is recommended that you main- tain a minimum 18” above the top of louver opening.

When locating the termination cap, it is important to observe the minimum vent height and clearances required under code, see Venting Installation Instructions, page 7.

Do not recess termination cap into a wall or siding.

You may paint the termination cap with 450°F (232°C) heat- resistant paint to coordinate with the exterior finish.

Flush with a wall

 

Through exterior wall

Corner

enclosed in a chase

Installation

Figure 2 - Common Fireplace Locations

25"

(635 mm)

15"

(381 mm)

36"

(914 mm)

Figure 3 - Fireplace Bottom Dimensions

117437-01

www.desatech.com

Image 5
Contents Inch B-VENT Decorative GAS Fireplaces For Your Safety OWNER’S Operation and Installation ManualFor Your Safety What to do if YOU Smell GAS Save this manual for future referencePage Safety Information Table of ContentsLocal Codes Product IdentificationPRE-INSTALLATION Preparation Product FeaturesFraming and Finishing PRE-INSTALATION PreparationClearances Mantel Clearances Unit DimensionsTypical B-Vent Configuration Installation Precautions Venting InstallationChecking for Proper Venting Venting InstallationElectrical Supply Connection Wiring DiagramsElectronic Ignition Wiring Diagram Installing Optional Wall Mount Switch GWMS2 Installing Optional ControlsReceiver Volt Alkaline Battery Terminal Wires Battery Clip Installing Remote ReceiverInstalling GAS Piping to Fireplace High Altitude InstallationGAS Supply and Piping Check GAS TypeNatural From Installation Items NeededTest Pressures In Excess of 1/2 Psig 3.5 kPa Checking GAS ConnectionsTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Equipment Shutoff Open Valve ClosedRemoving Lower Louver Access Panel Hearth Access and AssemblyRemoving Top Louver Trim Panel Removing/Replacing Glass DoorApplying Ember Material Installing Logs and Glowing EmbersManual Lighting Procedure For Your Safety Read Before LightingOperating Fireplace Lighting InstructionsOperating Fireplace Electronic Ignition System Optional Wireless Remote OperationON/OFF Series Model HRC100 Operating Optional GWMS2 ON/OFF Wall Mounted SwitchOptional HAND-HELD Remote Operation AIR Adjustment Setting Pilot AssemblyInspecting Burners Burner Flame PatternGlass Door Cleaning and MaintenancePilot and Burners LogsPilot unit TroubleshootingNeedle, or similar object to Or cycles during operation Gas leak. See Warning statement Ment Parts, Gas leak. See Warning statement at Technical Service Replacement Parts Service HintsSpecifications Parts Under WarrantyIllustrated Parts Breakdown KEY Parts ListVCB36N VCB36NEBurner Assembly for Models VCB36N, VCB36P Description QTY Burner Assembly for Models VCB36NE, VCB36PE KEY VCB36NE VCB36PE Description QTY Remote Control KIT WRC Series AccessoriesOWNER’S Registration Form Industrial Drive Box Bowling Green, KY 117437-01 117437-01 Page Industrial Drive P.O. Box Keep this WarrantyModel Serial No Date Purchased