VENTING INSTALLATION
Parts Lists for Venting Kits and Components (Cont.)
INSTALLATION
Wall Switch Installation
VENTING INSTALLATION
Continued
Vanguard Rigid Venting (Cont.)
Number | Description |
D1000 | 7" x 12" Galvanized Coaxial Pipe (6 pcs.) |
D1010 | 7" x 24" Galvanized Coaxial Pipe (6 pcs.) |
D1020 | 7" x 48" Galvanized Coaxial Pipe (6 pcs.) |
D1030 | 7" Adjustable |
| (6 pcs.) |
D1050 | 7" x 6" Galvanized Coaxial Pipe (6 pcs.) |
D2000 | 7" x 90° Elbow (6 pcs.) |
D2010 | 7" x 45° Elbow (6 pcs.) |
D2060 | 7" x 45° Starter Elbow |
D3000 Wall Strap/Offset Support (6 pcs.) | |
D3010 | Storm Collar (6 pcs.) |
D3020 | Wall Thimble (6 pcs.) |
D3050 | Vertical Restrictor (6 pcs.) |
D3060 | Ceiling Firestop/Support (6 pcs.) |
D3070 | Rectangular Horizontal Rigid Vent Termination Cap |
D3090 | Cathedral Ceiling Support Box |
D4000 | Roof Flashing |
D4010 | Roof Flashing |
D4020 | Flex Connector (6 pcs.) |
D4030 | Flex Wall Thimble (6 pcs.) |
D4040 | 4" Hose Clamp (6 pcs.) |
D4050 | 7" Hose Clamp (6 pcs.) |
D5000 | Vinyl Siding Standoff (6 pcs.) |
Vanguard Flexible Venting
Number | Description |
FGFVK | Flex Ground Floor Vent Kit |
| Includes: Flex Adapter, 7" x 4' Flexible Pipe, 4" x 4' |
| Flexible Pipe, Wall Thimble, Horizontal Termination, |
| (4) Spacer Springs, (2) 4" Hose Clamps, (2) 7" Hose |
| Clamps, RTV Silicone, and 10 Screws |
D1040 | 7" x 25' Coaxial Flex Pipe with Spacer Springs |
D3080 | Rectangular Horizontal Flex Termination Cap |
Simpson Dura-Vent GS 4" x 6 5/8 "
Number Description
9027" x 48" Pipe
9037" x 36" Pipe
9047" x 24" Pipe
9067" x 12" Pipe
9077" x 9" Pipe
9087" x 6" Pipe
Simpson
Number Description
9117" Adjustable
940Wall Thimble
941Cathedral Ceiling Support Box
943Roof Flashing
943S Roof Flashing
9457" x 45° Elbow
950Vinyl Siding Standoff
953Storm Collar
963Ceiling Firestop
98136" Snorkel Termination
984Horizontal Termination Vent Cap
988Wall Strap
9907" x 90° Elbow
991Vertical High Wind Termination
INSTALLATION
WALL SWITCH INSTALLATION
Since the VDVF36 series models use a valve that operates on millivolt current generated by the pilot, a wall switch may be used to activate the gas control valve without the use of normal household electricity.
1.To remove the louvers, simultaneously pull both top end spring latches towards the center of the appliance until they are dis- engaged from locating holes. Repeat for bottom end spring latches and pull outward. Reverse the procedure to install lou- vers back onto the appliance (see Figure 32).
Glass
Locating
Holes
Spring
Latch
Figure 32 - Removing Louver