Desa VDVF36STN/STP Lighting Instructions, Optional Remote Operation, To Turn OFF GAS To Appliance

Page 23

OPERATING FIREPLACE

Continued

LIGHTING

INSTRUCTIONS

1.

STOP! Read the safety information in column 2, page 22,

 

before proceeding.

 

2.

Set the “HI-LO” knob to the lowest setting.

 

3.

Turn off all electrical power to the appliance.

 

4.

Open control access panel.

 

5.

Push in gas control knob slightly and turn clockwise

 

to “OFF”.

 

6.

Wait five (5) minutes to clear out any gas. Then smell for

 

gas, including near the floor. If you smell gas, STOP! Fol-

 

low “B” in the safety information in column 2, page 22. If

 

you don’t smell gas, go to the next step.

 

7.

The pilot is located by the main burner.

 

8.

Turn knob on gas control counterclockwise

to

 

“PILOT”.

 

9.

Push in the control knob all the way and hold in. Immedi-

 

ately light the pilot by pressing the ignitor button until a

 

flame appears one (1) minute after the pilot is lit. Release

 

knob and it will pop back up. Pilot should remain lit. If it

 

goes out, repeat steps 5 through 9.

 

 

• If knob does not pop out when released, stop and call gas

 

supplier.

 

 

• If the pilot will not stay lit after several tries, turn gas

 

control knob to “OFF” and call your service technician

 

or gas supplier.

 

10.

Turn gas control knob counterclockwise

to “ON”.

 

Knob can be turned to “ON” only if the control knob is

 

popped out.

 

OPERATING FIREPLACE

23

Lighting Instructions

To Turn Off Gas To Appliance

 

Optional Remote Operation

 

 

 

3.Remove control access panel.

4.Push in gas control knob slightly and turn clockwise to “OFF”. Do not force.

5.Replace control access panel.

OPTIONAL REMOTE

OPERATION

Note: All remote control accessories must be purchased sepa- rately (see Accessories, page 29). Follow instructions included with the remote control.

NOTICE: You must light the pilot before using the hand-held remote control unit. See Lighting Instruc- tions, page 22.

1.After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Adjust flame adjustment knob anywhere between HI and LO. Slide the selector switch to the REMOTE position. Note: The burners may light if hand-held remote ON button was on when selector switch was last turned off. You can now turn the burners on and off with the hand-held remote control unit.

IMPORTANT: Do not leave the selector switch in the RE- MOTE position when the pilot is not lit. This will drain the battery.

IMPORTANT: Be sure to press the ON/OFF buttons on the hand-held remote control unit for up to 3 seconds to assure proper operation.

2.Press ON/OFF button to turn the burners on and off. When turning burners off, the pilot will remain lit.

11.

Set “HI-LO” knob to desired setting.

12.

Turn on all electric power to the appliance.

Gas Control Knob

 

HI/LO Knob

Position Indicator

 

 

O

 

 

 

 

IL

T

 

 

 

 

P

 

 

 

N

 

16AI

 

 

 

O

 

 

 

O

T

 

 

 

TH

 

 

 

7

I

 

 

L

 

 

 

 

P

L

I

 

 

 

 

 

 

 

FFO

O

H

 

TP

 

 

 

 

 

 

E A

 

 

 

TPTH

 

 

 

 

 

Figure 50 - Control Knob in the PILOT Position

TO TURN OFF GAS

TO APPLIANCE

Piezo Ignitor

Thermocouple

Figure 51 - Pilot

Flame Adjustment Knob

ON

OFF

REMOTE

Pilot Burner

Thermopile

Control Knob in On Position

IH

 

F

PIL

 

 

O

 

O

F

T

 

 

 

 

O

 

 

 

 

 

 

N

LO

 

 

 

1.Turn off the wall switch.

2.Turn off all electric power to the appliance if service is to be performed.

Selector Switch in Remote Position

(Optional Remote Control)

Figure 52 - Setting the Selector Switch, Control Knob, and Flame Adjustment Knob for Remote Operation

For morevisit www..com

105706-01B

Image 23
Contents What to do if YOU Smell GAS Check Local Codes Prior to InstallationProduct Dimensions Table of ContentsBack View Glossary of TermsBefore YOU Begin IntroductionSelecting Location Clearances PRE-INSTALLATION PreparationFraming Mantel ClearancesLocation of Vent Termination PRE-INSTALLATION Preparation General VentingGeneral Venting Installation Planning Venting InstallationInstallation Precautions Installing Vent System in a Chase Installation for Horizontal TerminationVent Opening Requirements Horizontal Venting Horizontal Termination ConfigurationsFlat Ceiling Installation Installation for Vertical TerminationVertical Termination Configurations Cathedral Ceiling InstallationVanguard Rigid Venting High Altitude InstallationParts Lists for Venting Kits and Components Simpson Dura-Vent GS 4 x 6 5/8 InstallationWall Switch Installation Vanguard Flexible VentingInstalling Receiver Optional Wireless HAND-HELD Remote Control InstallationElectrical Hookup for Blower Accessory GAS Line HOOK-UP Installing Battery in Hand-Held Remote Control UnitInstalling LOG SET GAS Supply TestingDecorative Facing Pilot Assembly AdjustmentBurner Removal Burner Flame AdjustmentOperating Guidelines and Maintenance Instructions Operating Fireplace Cleaning MaintenanceTo Turn OFF GAS To Appliance Lighting InstructionsOptional Remote Operation Parts Under Warranty Replacement Parts Service HintsTechnical Service Wiring DiagramObserved Problem Possible Cause Remedy TroubleshootingObserved Problem Possible Cause Company Gas leak. See Warning statement Blower KIT Davdbk Accessories Replacement Parts ListWall Switch KIT Pilot AssemblyScreen Assembly AssemblyDoor Assembly END Glass AssemblyOwners Registration Form Postage Required 105706-01B Warranty Information