Desa VDVF36PN/PP, VDVF36STN/STP installation manual Observed Problem Possible Cause

Page 26

26

TROUBLESHOOTING

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

When ignitor button is pressed, there is spark at pilot but no ignition

1.Gas supply turned off or equipment shutoff valve closed

2.Control knob not in PILOT position

3.Control knob not pressed in while in PILOT position

4.Air in gas lines when installed

5.Depleted gas supply (propane/LP models only)

6.Pilot is clogged

7.Gas regulator setting is not correct

1.Turn on gas supply or open equipment shutoff valve

2.Turn control knob to PILOT position

3.Press in control knob while in PILOT position

4.Continue holding down control knob. Repeat igniting operation until air is removed

5.Contact local propane/LP gas company

6.Clean pilot or replace pilot assembly

7.Replace gas control

Pilot lights but flame goes out when control knob is released

1.Control knob not fully pressed in

2.Control knob not pressed in long enough

3.Equipment shutoff valve not fully open

4.Pilot flame not touching thermocouple, which allows thermocouple to cool, causing pilot flame to go out. This prob- lem could be caused by one or both of the following:

A)Low gas pressure

B)Dirty or partially clogged pilot

5.Thermocouple connection loose at con- trol valve

6.Thermocouple damaged

7.Control valve damaged

1.Press in control knob fully

2.After pilot lights, keep control knob pressed in 30 seconds

3.Fully open equipment shutoff valve

4.A) Contact local propane/LP or natural gas company

B) Clean pilot or replace pilot assembly

5.Hand tighten until snug, then tighten 1/4 turn more

6.Replace thermocouple

7.Replace control valve

For..com

105706-01B

Image 26
Contents Check Local Codes Prior to Installation What to do if YOU Smell GASTable of Contents Product DimensionsGlossary of Terms Back ViewBefore YOU Begin IntroductionSelecting Location PRE-INSTALLATION Preparation ClearancesMantel Clearances FramingPRE-INSTALLATION Preparation General Venting Location of Vent TerminationGeneral Venting Installation Planning Venting InstallationInstallation Precautions Installation for Horizontal Termination Installing Vent System in a ChaseVent Opening Requirements Horizontal Termination Configurations Horizontal VentingInstallation for Vertical Termination Flat Ceiling InstallationCathedral Ceiling Installation Vertical Termination ConfigurationsVanguard Rigid Venting High Altitude InstallationParts Lists for Venting Kits and Components Vanguard Flexible Venting InstallationWall Switch Installation Simpson Dura-Vent GS 4 x 6 5/8Installing Receiver Optional Wireless HAND-HELD Remote Control InstallationElectrical Hookup for Blower Accessory Installing Battery in Hand-Held Remote Control Unit GAS Line HOOK-UPGAS Supply Testing Installing LOG SETPilot Assembly Adjustment Decorative FacingBurner Removal Burner Flame AdjustmentOperating Guidelines and Maintenance Instructions Cleaning Maintenance Operating FireplaceTo Turn OFF GAS To Appliance Lighting InstructionsOptional Remote Operation Wiring Diagram Replacement Parts Service HintsTechnical Service Parts Under WarrantyTroubleshooting Observed Problem Possible Cause RemedyObserved Problem Possible Cause Company Gas leak. See Warning statement Pilot Assembly Accessories Replacement Parts ListWall Switch KIT Blower KIT DavdbkEND Glass Assembly AssemblyDoor Assembly Screen AssemblyOwners Registration Form Postage Required 105706-01B Warranty Information