12
VENTING INSTALLATION
Installation for Horizontal Termination (Cont.)
VENTING INSTALLATION
Continued
Horizontal Termination Configurations
Figures 21 through 23 show different configurations for venting with horizontal termination. Each figure includes a chart with vertical minimum/maximum and horizontal maximum dimensions which must be met. All connections must be sealed with high temperature silicone sealant as specified in the second warning statement on page 9. All horizontal terminations require 1/4" rise per 12" of horizontal run.
FGFVK Vent Kit Shown
Note: The 30° Starter Elbow Must Be Discarded and Replaced with a 45° Starter Elbow.
Horizontal Venting
Vertical (V) | Horizontal (H) |
49.5" min. | 15" max. |
(45° elbow, 1' vertical pipe, 90° elbow)
61.5" min. | 34" max. |
73.5" min. | 58" max. |
85.5" min. | 10' max. |
102.5" min. | 20' max. |
45° Starter |
|
Elbow Required |
|
Horizontal Venting
See information in Figure 21 for Vertical(V) and Horizontal(H) maximums and minimums. The same amounts apply for flexible venting.
Figure 22 - Horizontal Termination Using Flexible Venting
Venting with Two 90° Elbows
Vertical (V) | Horizontal (H1) + |
| Horizontal (H2) |
5' min. | 4' max. |
6' min. | 8' max. |
7' min. | 10' max. |
8' min. | 15' max. |
20' max. | 20' max. |
Figure 21 - Horizontal Termination Configuration for Rigid
Venting Using One 90° Elbow
45° Starter
Elbow
Required
Figure 23 - Horizontal Termination Configuration for Rigid
Venting Using Two 90° Elbows with Termination at 90° with
Fireplace