Desa VDVF36PN/PP, VDVF36STN/STP installation manual Pilot Assembly Adjustment, Decorative Facing

Page 20

20

INSTALLATION

Installing Log Set (Cont.)

Decorative Facing

PILOT ASSEMBLY ADJUSTMENT

INSTALLATION

Continued

7.Figure 43 shows the top view of the burner and grate.

8.Place logs “A” as shown in Figure 44.

9.Place logs “B” as shown in Figure 45. Lift the end of log “A” that will be propped up and place log “B” under it. At the same time, the other side of log “B” is placed over the other log “A”. Repeat procedure for the other log “B”.

10.Take twigs “C” (shaped like a “Y”) and place them as shown in Figure 46.

11.Take twigs “D” (bent twig) and place them as shown in Figure 46.

12.Place twig “E” across the top of logs “B” a shown in Figure 46.

13.When finished installing the logs, close the glass doors while making certain that the safety door switch is fully depressed by the door frame before securing the four (4) spring loaded latches.

14.Replace the louvers in reverse order with the grilles pointing in the down position.

 

Left

Back

Front

Right

Figure 43 - Burner and Grate (Top View)

Left

WARNING: Improper installation, adjustment, al- teration, service, or maintenance can cause injury or property damage. Refer to this manual. For assis- tance or additional information, consult a qualified installer, service agency, or gas supplier.

 

 

Left

 

 

D

 

C

 

 

 

Back

 

E

Front

 

 

 

C D

Right

Figure 46 - Installing Twigs “C, D, E ” (Top View)

DECORATIVE FACING

Any noncombustible material may be used for facing (glass, tile, brick, etc.) as long as the proper clearances are observed (see Clearances, page 5). IMPORTANT: Louvered openings must not be obstructed, and upper and lower panels must remain removable for servicing. Use only heat-resistant, noncombustible mortar or adhesive when securing facing material.

Note: Combustible material, such as wood, that has been fire- proofed is not considered noncombustible.

Back

Front

Right

Figure 44 - Installing Logs “A” (Top View)

 

 

Left

 

Back

 

A

Front

B

B

 

 

 

 

 

 

 

A

 

Right

Figure 45 - Installing Logs “B ” (Top View)

PILOT ASSEMBLY

ADJUSTMENT

The pilot assembly is factory preset for the proper flame height. Alteration to these settings may have occurred during shipping and handling. If this is the case, some minor adjustment may be necessary and should be done by a qualified technician. To access the pilot assembly, the glass door must be opened. The proper settings for the thermopile height should be at a distance of 3/8" to 1/2" from the pilot flame as shown in Figure 47.

1/8"

 

(0.3cm)

3/8" - 1/2"

 

 

(.95cm-1.3cm)

Figure 47 - Correct Pilot Flame Pattern

For..com

105706-01B

Image 20
Contents Check Local Codes Prior to Installation What to do if YOU Smell GASTable of Contents Product DimensionsGlossary of Terms Back ViewBefore YOU Begin IntroductionSelecting Location PRE-INSTALLATION Preparation ClearancesMantel Clearances FramingPRE-INSTALLATION Preparation General Venting Location of Vent TerminationGeneral Venting Installation Planning Venting InstallationInstallation Precautions Installation for Horizontal Termination Installing Vent System in a ChaseVent Opening Requirements Horizontal Termination Configurations Horizontal VentingInstallation for Vertical Termination Flat Ceiling InstallationCathedral Ceiling Installation Vertical Termination ConfigurationsVanguard Rigid Venting High Altitude InstallationParts Lists for Venting Kits and Components Installation Wall Switch InstallationVanguard Flexible Venting Simpson Dura-Vent GS 4 x 6 5/8Installing Receiver Optional Wireless HAND-HELD Remote Control InstallationElectrical Hookup for Blower Accessory Installing Battery in Hand-Held Remote Control Unit GAS Line HOOK-UPGAS Supply Testing Installing LOG SETPilot Assembly Adjustment Decorative FacingBurner Removal Burner Flame AdjustmentOperating Guidelines and Maintenance Instructions Cleaning Maintenance Operating FireplaceTo Turn OFF GAS To Appliance Lighting InstructionsOptional Remote Operation Replacement Parts Service Hints Technical ServiceWiring Diagram Parts Under WarrantyTroubleshooting Observed Problem Possible Cause RemedyObserved Problem Possible Cause Company Gas leak. See Warning statement Accessories Replacement Parts List Wall Switch KITPilot Assembly Blower KIT DavdbkAssembly Door AssemblyEND Glass Assembly Screen AssemblyOwners Registration Form Postage Required 105706-01B Warranty Information