Desa VDVF36STN/STP Optional Wireless HAND-HELD Remote Control Installation, Installing Receiver

Page 17

INSTALLATION

Wall Switch Installation (Cont.) Electrical Hookup for Blower Accessory Optional Wireless Hand-Held Remote Control (GHRC(TA) Series) Installation

17

INSTALLATION

Continued

2.Connect the 18 ga. wires from wall switch to the gas control valve and microswitch, as shown in Figure 33.

WARNING: Do not wire remote wall switch to main power supply (Standard 120v household current).

Wall Switch

(Supplied)

OPTIONAL WIRELESS HAND-HELD REMOTE CONTROL INSTALLATION

Note: If using an optional wireless hand-held remote control, the wall switch is no longer operational.

NOTICE: Only use alkaline batteries (not included).

Installing Receiver

To Thermopile

 

 

 

O

 

 

 

 

IL

T

 

 

 

 

P

 

 

 

N

 

16AI

 

 

 

O

 

 

 

O

T

 

 

 

TH

L

 

 

7

I

 

 

P

L

I

 

 

 

FFO

O

 

 

 

H

 

TP

 

E

A

 

 

TPTH

 

 

 

 

Route Millivolt Wires

(Back View)

 

(Supplied) Through Gas

 

Line Conduit Sleeve

 

Figure 33 - Wall Switch Wiring Diagram

Note: If any of the original wire supplied must be replaced, use type 18 AWG-105 degree C (25 feet length MAXIMUM) or equivalent.

ELECTRICAL HOOKUP FOR BLOWER ACCESSORY

Before blower accessory can be operated, it must be properly connected to a standard 120 VAC power source. Refer to Wiring Diagram on page 24.

An outlet box with two receptacles has been supplied for your convenience, located on the lower left side of the appliance (see Figure 34). An optional remote control may be installed at any time.

1.Remove access panel from lower front face of firebox. Lift straight up on access panel until it stops. Pull bottom of access panel forward, then down.

2.Disconnect wall switch wires from TH and TPTH terminals on control valve (see Figure 33).

3.Install remote receiver unit onto mounting bracket using the two plastic mounting clips (see Figure 35).

4.Connect wires to control valve. Connect white wire to termi- nal TH. Connect red wire to terminal TPTH.

5.Locate the battery clip mounted on the back of the receiver (see Figure 36).

6.Slide 9-volt battery (not included) through the clip.

7.Attach the terminal wires to the battery (see Figure 36).

8.Replace access panel. Place top of access panel into opening and slide up. Push bottom of access panel in and slide down to install.

Plastic

ReceiverMounting

Clips

Mounting

Bracket

Figure 35 - Installing Remote Receiver (Shown from Rear of Mounting Bracket)

CAUTION: Due to high temperatures, make sure no wires are touching the bottom of the firebox.

For Optional

Fan Kit

From Blower

Assembly

Figure 34 - Connecting Blower Accessory to Power Supply

9-Volt Battery

Battery Clip

Receiver

Terminal Wires

Figure 36 - Installing Battery in Receiver

For morevisit www..com

105706-01B

Image 17
Contents What to do if YOU Smell GAS Check Local Codes Prior to InstallationProduct Dimensions Table of ContentsBack View Glossary of TermsBefore YOU Begin IntroductionSelecting Location Clearances PRE-INSTALLATION PreparationFraming Mantel ClearancesLocation of Vent Termination PRE-INSTALLATION Preparation General VentingGeneral Venting Installation Planning Venting InstallationInstallation Precautions Installing Vent System in a Chase Installation for Horizontal TerminationVent Opening Requirements Horizontal Venting Horizontal Termination ConfigurationsFlat Ceiling Installation Installation for Vertical TerminationVertical Termination Configurations Cathedral Ceiling InstallationVanguard Rigid Venting High Altitude InstallationParts Lists for Venting Kits and Components Wall Switch Installation InstallationVanguard Flexible Venting Simpson Dura-Vent GS 4 x 6 5/8Installing Receiver Optional Wireless HAND-HELD Remote Control InstallationElectrical Hookup for Blower Accessory GAS Line HOOK-UP Installing Battery in Hand-Held Remote Control UnitInstalling LOG SET GAS Supply TestingDecorative Facing Pilot Assembly AdjustmentBurner Removal Burner Flame AdjustmentOperating Guidelines and Maintenance Instructions Operating Fireplace Cleaning MaintenanceTo Turn OFF GAS To Appliance Lighting InstructionsOptional Remote Operation Technical Service Replacement Parts Service HintsWiring Diagram Parts Under WarrantyObserved Problem Possible Cause Remedy TroubleshootingObserved Problem Possible Cause Company Gas leak. See Warning statement Wall Switch KIT Accessories Replacement Parts ListPilot Assembly Blower KIT DavdbkDoor Assembly AssemblyEND Glass Assembly Screen AssemblyOwners Registration Form Postage Required 105706-01B Warranty Information