Installation
Continued
For propane/LP units, the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11" and 14" of water. If you do not reduce incoming gas pres- sure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 17. Pointing the vent down protects it from freezing rain or sleet.
CAUTION:Useonlynew,black
Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from fireplace (see Figure 18).
IMPORTANT: Install equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance.
Check your building codes for any special re- quirements for locating equipment shutoff valve to fireplaces.
Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fire- place valves. Never use sealant on flare threads.
External | Propane/LP |
Regulator | Supply Tank |
Vent Pointing Down
Figure 17 - External Regulator on Propane/LP Supply Tank with Vent Pointing Down
WARNING: Use pipe joint sealant that is resistant to liquid petroleum (LP) gas.
We recommend that you install a sediment trap in supply line as shown in Figure 18. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and fireplace. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into fireplace gas controls. If sediment trap is not installed or is installed wrong, fireplace may not run properly.
CSA
Equipment Shutoff Valve
With 1/8" NPT Tap*
| Natural Gas |
| From Gas |
| Meter |
| (5" W.C.** to |
| 10.5" W.C. |
3" Minimum | Pressure) |
|
|
|
|
| Propane/LP |
Cap Pipe | Tee |
| From External | |
Nipple | Joint |
| Regulator | |
|
|
|
| (11" W.C.** |
|
|
|
| |
Sediment Trap |
| to 14" W.C. | ||
|
|
|
| Pressure) |
Figure 18 - Gas Connection
*Purchase the optional CSA
Accessories, page 32.
** Minimum inlet pressure for purpose of input adjustment.
www.desatech.com | 13 |