Desa VSGF33NRC To Turn OFF GAS To Appliance, Manual Lighting Procedure, OpTIONAL Hand-Held

Page 18

OPERATING fireplace

Continued

7.With control knob pressed in, press and release ignitor button. This will light pilot.

The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see

Manual Lighting Procedure.

8.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

• If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

Note: If pilot goes out, repeat steps 4 through 8 beginning on page 17.

9.Slightly push in and turn control knob coun-

terclockwise to the ON position.

10.Wait one minute and switch selector switch to the ON position to light burners.

11.Set flame adjustment knob to any level between HI and LO.

WARNING: Make sure the selector switch is in the OFF position when you are away from home for long periods of time. Heater will come on automati- cally with selector switch in the ON position.

Pilot Burner

Ignitor

 

Electrode

Figure 28 - Pilot (Natural)

Pilot Burner

Ignitor

 

Electrode

Figure 29 - Pilot (Propane/LP)

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1. Turn control knob clockwise to the OFF position.

2a. Set selector switch in the OFF position.

2b. If Using Optional Hand-Held Remote: Set selector switch in the OFF position to keep from draining battery.

Shutting Off Burners Only (pilot stays lit) You may shut off the burners and keep the pilot lit by doing one of the following:

Turn control knob clockwise to the PILOT position.

Use remote control manual OFF button.

Set selector switch in the OFF position.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 6 under Lighting Instructions, page 17.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow steps 9 through 11, column 1.

OpTIONAL Hand-Held

REMOTE OPERATION

Note: All remote control accessories must be purchased separately (see Accessories, page 32). Follow instructions included with the remote control.

NOTICE: You must light the pilot before using the hand-held re- mote control unit. See Lighting Instructions, page 17.

After lighting, let pilot flame burn for about one minute. Turn control knob to ON posi- tion. Adjust flame adjustment knob anywhere between HI and LO. Slide the selector switch to the REMOTE position (see Figure 30, page 19). Note: The burner may light if hand-held remote was on when selector switch was last turned off. You can now turn the burner on and off with the hand-held remote control unit.

IMPORTANT: Do not leave the selector switch in the REMOTE or ON position when the pilot is not lit. This will drain the battery.

18

www.desatech.com

119304-01A

Image 18
Contents VSGF33PRC and VSGF33NRC Remote-ready fireplace SystemTable of Contents Safety Information Product Identification Local CodesUnpacking Product FeaturesAccessory Air For Combustion VentilationAIR for Combustion Ventilation Providing Adequate VentilationDetermining FRESH-AIR Flow for Fireplace Location Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Check GAS Type InstallationInstalling Hood Electrical HookupInstallation Clearances ExampleConventional Fireplace Installation Installing Gas Piping to Fireplace Location,Front Width Built-In Fireplace InstallationActual Framing Height DepthInstalling Gas Piping to Fireplace Location Mantel Clearances for Built-In InstallationInstallation Items Needed Vent Pointing Down Propane/LPConnecting Fireplace to Gas Supply Checking GAS ConnectionsNatural Gas Pressure Testing Fireplace Gas Connections Test Pressures Equal To or Less Than Psig 3.5 kPaInstalling Logs Installing Bottom LogsLighting For Your Safety Read Before LightingOperating Fireplace InstructionsOpTIONAL Hand-Held Manual Lighting ProcedureTo Turn OFF GAS To Appliance Remote OperationOn/Off Model HRC100 Thermostat Model HRC200Pilot Flame Pattern Inspecting BurnersOptional Blower Operation Main burnerCleaning Maintenance Inspecting BurnersBurner Injector Holder and Pilot Air Inlet Hole Specifications Cleaning MaintenanceWiring Diagram LogsTroubleshooting Observed Problem Possible Cause RemedyTroubleshooting Diagram,Stalling Logs, Gas leak. See Warning Statement aboveTechnical Service Replacement PartsService Hints Parts Under WarrantyLog Base Assembly Models VSGF33NRC and VSGF33PRC Illustrated Parts BreakdownParts List Illustrated Parts Breakdown Fireplace mOdels VSGF33NRC and VSGF33PRCParts List Receiver and HAND-HELD Remote Control KIT HRC100 AccessoriesReceiver and HAND-HELD Thermostat Remote Control KIT HRC200 Equipment Shutoff Valve GA5010Accessories WALL-MOUNT ON/OFF SwitchWALL-MOUNT Thermostat 119304-01A 119304-01A Warranty Information Keep this WarrantyLimited Warranty VENT-FREE GAS Fireplace