Desa VSGF33NRC, VSGF33PRC installation manual Troubleshooting, Diagram

Page 24

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

ODS/pilot lights but flame goes

1. Control knob not fully

1.

Press in control knob fully

out when control knob is re-

 

pressed in

2.

After ODS/pilot lights, keep con-

leased

2. Control knob not pressed in

 

3.

long enough

3.

trol knob pressed in 30 seconds

 

Equipment shutoff valve not

Fully open equipment shutoff

 

4.

fully open

4.

valve

 

Pilot flame not touching

A) Contact local natural or

 

 

thermocouple, which allows

 

propane/LP gas company

 

 

thermocouple to cool, caus-

 

B) Clean ODS/pilot (see

 

 

ing pilot flame to go out. This

 

 

 

problem could be caused by

 

Cleaning and Maintenance,

 

 

one or both of the following:

 

page 21) or replace ODS/pilot

 

 

A) Low gas pressure

 

assembly

 

 

B) Dirty or partially clogged

 

 

 

 

5.

ODS/pilot

5.

Hand tighten until snug, then

 

Thermocouple connection

 

6.

loose at control valve

6.

tighten 1/4 turn more

 

Thermocouple damaged

Replace pilot assembly

 

7.

Control valve damaged

7.

Replace control valve

 

 

 

 

 

Burner does not light after ODS/

1. Inlet gas pressure is too low

1.

Contact local natural or pro-

pilot is lit

2.

Burner orifice(s) clogged

2.

pane/LP gas company

 

Clean burner(s) (see Cleaning

 

 

 

 

and Maintenance, page 21) or

 

3.

Thermopile leads disconnected

3.

replace burner orifice(s)

 

Reconnect leads (see Wiring

 

4.

or improperly connected

4.

Diagram, page 22)

 

Burner will not come on in

Replace battery in transmitter

 

 

remote position

 

and receiver

 

 

 

 

 

Delayed ignition of one or both

1. Manifold pressure is too

1.

Contact local natural or pro-

burners

2.

low

2.

pane/LP gas company

 

Burner orifice(s) clogged

Clean burner(s) (see Cleaning

 

 

 

 

and Maintenance, page 21) or

 

 

 

 

replace burner orifice(s)

 

 

 

 

 

Burner backfiring during

1. Burner orifice is clogged or

1.

Clean burner (see Cleaning

combustion

 

damaged

 

and Maintenance, page 21) or

 

2.

Damaged burner

2.

replace burner orifice(s)

 

Replace damaged burner

 

3.

Gas regulator defective

3.

Replace gas regulator

 

 

 

 

 

Slight smoke or odor during initial

1. Not enough air

1.

Check burner for dirt and

operation

 

 

 

debris. If found, clean burner

 

 

 

 

(see Cleaning and Mainte-

 

2.

Gas regulator defective

2.

nance, page 21)

 

Replace gas control

 

3.

Residues from manufacturing

3.

Problem will stop after a few

 

 

processes and logs curing

 

hours of operation

24

www.desatech.com

119304-01A

Image 24
Contents VSGF33PRC and VSGF33NRC Remote-ready fireplace SystemTable of Contents Safety Information Product Identification Local CodesProduct Features AccessoryUnpacking Air For Combustion VentilationAIR for Combustion Ventilation Providing Adequate VentilationDetermining FRESH-AIR Flow for Fireplace Location Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Installing HoodCheck GAS Type Electrical HookupInstallation Clearances ExampleConventional Fireplace Installation Installing Gas Piping to Fireplace Location,Built-In Fireplace Installation Actual Framing HeightFront Width DepthInstalling Gas Piping to Fireplace Location Mantel Clearances for Built-In InstallationInstallation Items Needed Vent Pointing Down Propane/LPConnecting Fireplace to Gas Supply Checking GAS ConnectionsNatural Gas Pressure Testing Fireplace Gas Connections Test Pressures Equal To or Less Than Psig 3.5 kPaInstalling Logs Installing Bottom LogsFor Your Safety Read Before Lighting Operating FireplaceLighting InstructionsManual Lighting Procedure To Turn OFF GAS To ApplianceOpTIONAL Hand-Held Remote OperationOn/Off Model HRC100 Thermostat Model HRC200Inspecting Burners Optional Blower OperationPilot Flame Pattern Main burnerCleaning Maintenance Inspecting BurnersBurner Injector Holder and Pilot Air Inlet Hole Cleaning Maintenance Wiring DiagramSpecifications LogsTroubleshooting Observed Problem Possible Cause RemedyTroubleshooting Diagram,Stalling Logs, Gas leak. See Warning Statement aboveReplacement Parts Service HintsTechnical Service Parts Under WarrantyLog Base Assembly Models VSGF33NRC and VSGF33PRC Illustrated Parts BreakdownParts List Illustrated Parts Breakdown Fireplace mOdels VSGF33NRC and VSGF33PRCParts List Accessories Receiver and HAND-HELD Thermostat Remote Control KIT HRC200Receiver and HAND-HELD Remote Control KIT HRC100 Equipment Shutoff Valve GA5010Accessories WALL-MOUNT ON/OFF SwitchWALL-MOUNT Thermostat 119304-01A 119304-01A Warranty Information Keep this WarrantyLimited Warranty VENT-FREE GAS Fireplace