INSTALLING LOGS

WARNING: Failure to posi- tion the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.

CAUTION: Do not remove the data plates attached to the heater base assembly. The data plates contain important safety and warranty information.

It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.

1.Place bottom log in center of the base assem- bly as shown in Figure 24.

2.Rest rear log in back corner sections of base assembly as shown in Figure 24. Make sure log is completely vertical and not leaning in toward burner where the flame will touch the log.

3.Position front right log against right side of grate prongs (see Figure 24).

4.Position front left log against left side of grate prongs (see Figure 24).

5.Place middle right log over front right and bot- tom logs as shown in Figure 25. Be sure hole in middle right log seats over pin in bottom log.

6.Place middle left log over front left and bot- tom logs as show in Figure 25. Be sure hole in middle left log seats over pin in front left log.

7.Install fireplace screen by slipping notches of fireplace screen over screws on front of fireplace (see Figure 26).

WARNING:You must operate this fireplace with the fireplace screen in place. Make sure fire- place screen is in place before running fireplace.

Front

 

Left Log

Rear Log

Grate

 

Bottom

 

Log

Prongs

 

Base

Front Right

 

Assembly

 

Log

 

 

Figure 24 - Installing Bottom Logs

Middle Left Log

Middle

Right Log

Pin on Front

Bottom

Left Log

Log

Figure 25 - Installing Top Logs

Notches

Screws for

Mounting Screen

Figure 26 - Installing Fireplace Screen

16

www.desatech.com

119304-01A

Image 16
Contents VSGF33PRC and VSGF33NRC Remote-ready fireplace SystemTable of Contents Safety Information Product Identification Local CodesProduct Features AccessoryUnpacking Air For Combustion VentilationProviding Adequate Ventilation AIR for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation Installing HoodCheck GAS Type Electrical HookupInstallation Clearances ExampleConventional Fireplace Installation Installing Gas Piping to Fireplace Location,Built-In Fireplace Installation Actual Framing HeightFront Width DepthMantel Clearances for Built-In Installation Installing Gas Piping to Fireplace LocationInstallation Items Needed Vent Pointing Down Propane/LPChecking GAS Connections Connecting Fireplace to Gas SupplyNatural Gas Pressure Testing Fireplace Gas Connections Test Pressures Equal To or Less Than Psig 3.5 kPaInstalling Logs Installing Bottom LogsFor Your Safety Read Before Lighting Operating FireplaceLighting InstructionsManual Lighting Procedure To Turn OFF GAS To ApplianceOpTIONAL Hand-Held Remote OperationOn/Off Model HRC100 Thermostat Model HRC200Inspecting Burners Optional Blower OperationPilot Flame Pattern Main burnerInspecting Burners Cleaning MaintenanceBurner Injector Holder and Pilot Air Inlet Hole Cleaning Maintenance Wiring DiagramSpecifications LogsTroubleshooting Observed Problem Possible Cause RemedyTroubleshooting Diagram,Stalling Logs, Gas leak. See Warning Statement aboveReplacement Parts Service HintsTechnical Service Parts Under WarrantyLog Base Assembly Models VSGF33NRC and VSGF33PRC Illustrated Parts BreakdownParts List Illustrated Parts Breakdown Fireplace mOdels VSGF33NRC and VSGF33PRCParts List Accessories Receiver and HAND-HELD Thermostat Remote Control KIT HRC200Receiver and HAND-HELD Remote Control KIT HRC100 Equipment Shutoff Valve GA5010WALL-MOUNT ON/OFF Switch AccessoriesWALL-MOUNT Thermostat 119304-01A 119304-01A Keep this Warranty Warranty InformationLimited Warranty VENT-FREE GAS Fireplace