Desa VSGF33PRC, VSGF33NRC Troubleshooting, Observed Problem Possible Cause Remedy

Page 23

Troubleshooting

WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater.

CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/pilot unit.

Note: All troubleshooting items are listed in order of operation.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

When ignitor button is pressed,

1. Ignitor electrode not con-

1.

Reconnect ignitor cable

there is no spark at ODS/pilot

2.

nected to ignitor cable

2.

Free ignitor cable if pinched

 

Ignitor cable pinched or wet

 

 

 

 

by any metal or tubing. Keep

 

3.

Piezo ignitor nut is loose

3.

ignitor cable dry

 

Tighten nut holding piezo ignitor

 

 

 

 

to base panel of log set. Nut is

 

4.

Broken ignitor cable

4.

located behind base panel

 

Replace ignitor cable

 

5.

Bad piezo ignitor

5.

Replace piezo ignitor

 

6.

Ignitor electrode broken

6.

Replace pilot assembly

 

7.

Ignitor electrode positioned

7.

Replace pilot assembly

 

 

wrong

 

 

 

 

 

 

 

 

When ignitor button is pressed,

1. Gas supply turned off or equip-

1.

Turn on gas supply or open

there is spark at ODS/pilot but

 

ment shutoff valve closed

2.

equipment shutoff valve

no ignition

2. Control knob not in PILOT

Turn control knob to PILOT

 

3.

position

3.

position

 

Control knob not pressed in

Press in control knob while in

 

4.

while in PILOT position

4.

PILOT position

 

Air in gas lines when in-

Continue holding down control

 

 

stalled

 

knob. Repeat igniting opera-

 

5.

Depleted gas supply (propane/

5.

tion until air is removed

 

Contact local propane/LP gas

 

6.

LP only)

6.

company

 

ODS/pilot is clogged

Clean ODS/pilot (see Cleaning

 

 

 

 

and Maintenance, page 21) or

 

7.

Gas regulator setting is not

7.

replace ODS/pilot assembly

 

Replace gas regulator

 

 

correct

 

 

 

119304-01A

www.desatech.com

23

Image 23
Contents Remote-ready fireplace System VSGF33PRC and VSGF33NRCTable of Contents Safety Information Local Codes Product IdentificationAir For Combustion Ventilation Product FeaturesAccessory UnpackingDetermining FRESH-AIR Flow for Fireplace Location AIR for Combustion VentilationProviding Adequate Ventilation Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Electrical Hookup InstallationInstalling Hood Check GAS TypeExample Installation ClearancesInstalling Gas Piping to Fireplace Location, Conventional Fireplace InstallationDepth Built-In Fireplace InstallationActual Framing Height Front WidthInstallation Items Needed Installing Gas Piping to Fireplace LocationMantel Clearances for Built-In Installation Propane/LP Vent Pointing DownNatural Gas Connecting Fireplace to Gas SupplyChecking GAS Connections Test Pressures Equal To or Less Than Psig 3.5 kPa Pressure Testing Fireplace Gas ConnectionsInstalling Bottom Logs Installing LogsInstructions For Your Safety Read Before LightingOperating Fireplace LightingRemote Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance OpTIONAL Hand-HeldThermostat Model HRC200 On/Off Model HRC100Main burner Inspecting BurnersOptional Blower Operation Pilot Flame PatternBurner Injector Holder and Pilot Air Inlet Hole Cleaning MaintenanceInspecting Burners Logs Cleaning MaintenanceWiring Diagram SpecificationsObserved Problem Possible Cause Remedy TroubleshootingDiagram, TroubleshootingStalling Logs, Statement above Gas leak. See WarningParts Under Warranty Replacement PartsService Hints Technical ServiceIllustrated Parts Breakdown Log Base Assembly Models VSGF33NRC and VSGF33PRCParts List Fireplace mOdels VSGF33NRC and VSGF33PRC Illustrated Parts BreakdownParts List Equipment Shutoff Valve GA5010 AccessoriesReceiver and HAND-HELD Thermostat Remote Control KIT HRC200 Receiver and HAND-HELD Remote Control KIT HRC100WALL-MOUNT Thermostat AccessoriesWALL-MOUNT ON/OFF Switch 119304-01A 119304-01A Limited Warranty VENT-FREE GAS Fireplace Warranty InformationKeep this Warranty