Hearth and Home Technologies 36, 42 owner manual TCT1175 Terra Cotta Cap

Page 21

TCT1175 Terra Cotta Cap

 

Place waterproof sealer

Remove 2 screws

under each flange of the

termination cap and on

from front & back

top of each screw to

to lift the top off

help prevent leaks.

 

Termination Cap

The last section of pipe

 

must stop between 2 in.

 

(51 mm) above top of

Collar

chase and 7 in. (178 mm)

below top of chase

2 in. (51 mm)

 

Minimum Height

 

Chase Top

2 in. (51 mm

 

7 in. (178 mm

 

Chase

Chimney

 

Pipe

 

Termination cap pipe and chimney section must overlap

1-1/2 in. (38 mm)

Figure 6.7 Installing a TCT1175 Terra Cotta Cap

Outdoor Lifestyles by Hearth & Home Technologies Inc. • Montana US-CAN4039-156 Rev K • 7/11

21

Image 21
Contents Fire Risk Hot glass will cause burnsListing Label Information/Location Serial Number GrateModel Table of Contents Listing and Code Approvals Appliance CertificationNot intended for use as a primary heat source Getting Started Design and Installation ConsiderationsMoisture Resistance Typical Fireplace SystemTools and Supplies Needed Inspect Fireplace and ComponentsFire Risk Explosion Risk Framing and Clearances Freestanding Installations see FigureSelecting Fireplace Location Exterior Walls see FigureEnclosed Fireplace Clearances to Combustible Materials ClearancesFrame the Fireplace Sidewalls/SurroundsChimney Requirements Installation of Fireplace Install the Dual Cooling Air KitSharp Edges Asphyxiation Risk Position the Fireplace Secure the FireplaceHeight of Chimney Components Chimney AssemblyChimney Offset/Return Using Offsets/ReturnsAssemble the Chimney Sections Install the Ceiling FirestopsDouble-check the Chimney Assembly Install the Attic Insulation ShieldSecure the Chimney  in./19 mm in lengthChimney Termination Complete the EnclosureMark the Exit Point of the Roof Chase TopST1175/ST475 Square Termination Cap Install the Termination CapTCT1175 Terra Cotta Cap Accessories Gas Log/Lighter ProvisionsGas Code, Ansi Z223.1 Hearth Extension FinishingFinishing Material MantelGlass Doors General Information Operating InstructionsClear Space Near the Fireplace Outside AirFlue Damper FirescreenWood Fuel GrateStarting a Fire Diagnostics and Problem Solving TroubleshootingChimney Inspection/Cleaning Maintenance and Servicing the FireplaceDisposal of Ashes Firebox RefractoryWhen cleaning glass door Maintenance Task ListClean Chimney FireReference Materials Fireplace DimensionsDescription Fireplace ComponentsCatalog # Chimney ComponentsAssembled Diameter 17 in./432 mm Height 24 in./610 mm 15-3/4 400 mm 635 x 635 mm 584 x 584 mm 737 x 737 mm Woodburning Termination CapMONTANA-36, MONTANA-36H D. Service PartsMONTANA-42, MONTANA-42H Service PartsThis page intentionally left blank This page intentionally left blank Warranty Coverage This warranty is void if Limited WarrantyRO N a CO ISD D