Hearth and Home Technologies 42 Accessories, Gas Log/Lighter Provisions, Gas Code, Ansi Z223.1

Page 22

7Accessories

A. Gas Log/Lighter Provisions

A certified gas log lighter or decorative gas log set can be installed in this fireplace.

This fireplace was not tested and listed for use with an un- vented gas log heater. Do not install an unvented gas log heater in this fireplace and operate it with the flue damper in the closed position unless the unvented gas log heater has been specifically tested and listed for use in this fireplace by Underwriters Laboratories Inc.

Use of an unvented gas log heater in this factory built fireplace may create a fire hazard that can result in a structure fire.

Maximum input is 100,000 BTU/hr.

Decorative gas appliance must be certified to ANSI Z21.60 “Standard for Decorative Gas Appliances for Installation in Vented Fireplaces”.

Must be installed in accordance with the National Fuel

Gas Code, ANSI Z223.1.

A log set must incorporate a gas shutoff.

Log set requires the damper to be locked fully open. Knockouts are provided on both sides of the fireplace and in refractories for 1/2 in. (13 mm) iron pipe.

We recommend you seal refractory around pipe with fireplace mortar or high temperature, noncombustible sealant.

Repack insulation from the knockout around the pipe.

Maintain 1-1/2 in. (38 mm) air space around the pipe for 4 in. (102 mm) beyond the fireplace.

See Figure 7.1.

WARNING

Asphyxiation Risk

Damper must be locked open when gas logs installed.

Gas fire generates fumes.

WARNING

Fire Risk

For use with solid wood fuel or decorative gas appliance only.

DO NOT install unvented gas logs.

WARNING

Fire Risk

Explosion Risk

Inspect appliance and components for damage. Damaged parts may impair safe operation.

Do NOT install damaged components.

Do NOT install incomplete components.

Do NOT install substitute components

Report damaged parts to dealer.

Firebox

Refractory

Seal with fireplace mortar or non-combust- ible sealant

Outer shell of fireplace

Maintain air clearance to combustibles.

Combustible materials

Gas line

Gas line

Repack insulation

knockout 4 in. (102 mm)

Figure 7.1 Gas Line Installation

1 1/2 in. (38 mm) air space around

pipe

Combustible materials may be located at zero clearance to gas line beyond 4 in. (102 mm) from fireplace side.

22 Outdoor Lifestyles by Hearth & Home Technologies Inc. • Montana US-CAN4039-156 Rev K 7/11

Image 22
Contents Hot glass will cause burns Fire RiskSerial Number Grate Listing Label Information/LocationModel Table of Contents Appliance Certification Listing and Code ApprovalsNot intended for use as a primary heat source Moisture Resistance Design and Installation ConsiderationsGetting Started Typical Fireplace SystemInspect Fireplace and Components Tools and Supplies NeededFire Risk Explosion Risk Selecting Fireplace Location Freestanding Installations see FigureFraming and Clearances Exterior Walls see FigureEnclosed Fireplace Clearances Clearances to Combustible MaterialsSidewalls/Surrounds Frame the FireplaceChimney Requirements Install the Dual Cooling Air Kit Installation of FireplaceSharp Edges Asphyxiation Risk Secure the Fireplace Position the FireplaceChimney Assembly Height of Chimney ComponentsUsing Offsets/Returns Chimney Offset/ReturnInstall the Ceiling Firestops Assemble the Chimney SectionsSecure the Chimney Install the Attic Insulation ShieldDouble-check the Chimney Assembly  in./19 mm in lengthComplete the Enclosure Chimney TerminationChase Top Mark the Exit Point of the RoofInstall the Termination Cap ST1175/ST475 Square Termination CapTCT1175 Terra Cotta Cap Gas Log/Lighter Provisions AccessoriesGas Code, Ansi Z223.1 Finishing Hearth ExtensionMantel Finishing MaterialGlass Doors Operating Instructions General InformationFlue Damper Outside AirClear Space Near the Fireplace FirescreenGrate Wood FuelStarting a Fire Troubleshooting Diagnostics and Problem SolvingDisposal of Ashes Maintenance and Servicing the FireplaceChimney Inspection/Cleaning Firebox RefractoryClean Maintenance Task ListWhen cleaning glass door Chimney FireFireplace Dimensions Reference MaterialsFireplace Components DescriptionChimney Components Catalog #Assembled Diameter 17 in./432 mm Height 24 in./610 mm 15-3/4 400 mm Woodburning Termination Cap 635 x 635 mm 584 x 584 mm 737 x 737 mmD. Service Parts MONTANA-36, MONTANA-36HService Parts MONTANA-42, MONTANA-42HThis page intentionally left blank This page intentionally left blank Warranty Coverage Limited Warranty This warranty is void ifRO N a CO ISD D