Hearth and Home Technologies 42, 36 Maintenance and Servicing the Fireplace, Disposal of Ashes

Page 30

11 Maintenance and Servicing the Fireplace

A. Disposal of Ashes

Ashes should be placed in a metal container with a tight-fit- ting lid. The closed container of ashes should be placed on a noncombustible floor or on the ground, well away from all combustible materials, pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally dis- persed, they should be retained in the closed container until all embers have thoroughly cooled.

WARNING

Fire Risk

Disposal of ashes

Ashes should be placed in metal container with tight fitting lid.

Do not place metal container on combustible surface.

Ashes should be retained in closed container until all embers have thoroughly cooled.

WARNING

Fire Risk

Prevent creosote buildup

Inspect chimney once every two months during heating season.

Remove creosote to reduce risk of chimney fire.

Ignited creosote is extremely HOT.

B. Chimney Inspection/Cleaning

Inspect the chimney internally for obstructions and construc- tion damage. Flue pipe joints and seams must be continu- ous and mechanically tight.

The chimney should be inspected once every two months during the heating season.

If creosote has accumulated, it should be removed to reduce the risk of a chimney fire.

Refer to Figure 11.1 to remove/reinstall termination caps.

C. Firebox Refractory

Check firebox refractory for excessive cracks or gaps. If cracks exceed 1/4 in. (6 mm) in width the refractory should be replaced. See Section 12 for replacement information.

WARNING

Fire Risk

Inspect fireplace refractory annually.

Crumbling, deteriorated refractory can allow overheating of surrounding materials.

Note: As you use the fireplace, expansion and contraction will cause minor cracking of the refractory. This is normal, unavoidable, and will not affect the performance of the fireplace. If the cracks become large enough that the metal behind the refractory is exposed or large pieces fall out, the panels should be replaced.

Remove 4 screws

Remove screws,and lift top pan off. lift top cover. Top Cover

Cap

Cap

Chimney

 

 

Slip

 

Section

TR11/TR11T

ST1175/ST475

TR444/TR442

Square Termination Cap

Round Termination Cap

 

Remove 2 screws from the front and back and lift the top off.

TCT1175

Terra Cotta

Termination Cap

Figure 11.1 Chimney & Termination Cap Cleaning

30 Outdoor Lifestyles by Hearth & Home Technologies Inc. • Montana US-CAN4039-156 Rev K 7/11

Image 30
Contents Hot glass will cause burns Fire RiskListing Label Information/Location Serial Number GrateModel Table of Contents Listing and Code Approvals Appliance CertificationNot intended for use as a primary heat source Moisture Resistance Design and Installation ConsiderationsGetting Started Typical Fireplace SystemTools and Supplies Needed Inspect Fireplace and ComponentsFire Risk Explosion Risk Selecting Fireplace Location Freestanding Installations see FigureFraming and Clearances Exterior Walls see FigureEnclosed Fireplace Clearances Clearances to Combustible MaterialsSidewalls/Surrounds Frame the FireplaceChimney Requirements Installation of Fireplace Install the Dual Cooling Air KitSharp Edges Asphyxiation Risk Secure the Fireplace Position the FireplaceChimney Assembly Height of Chimney ComponentsUsing Offsets/Returns Chimney Offset/ReturnInstall the Ceiling Firestops Assemble the Chimney SectionsSecure the Chimney Install the Attic Insulation ShieldDouble-check the Chimney Assembly  in./19 mm in lengthComplete the Enclosure Chimney TerminationChase Top Mark the Exit Point of the RoofInstall the Termination Cap ST1175/ST475 Square Termination CapTCT1175 Terra Cotta Cap Accessories Gas Log/Lighter ProvisionsGas Code, Ansi Z223.1 Finishing Hearth ExtensionFinishing Material MantelGlass Doors Operating Instructions General InformationFlue Damper Outside AirClear Space Near the Fireplace FirescreenGrate Wood FuelStarting a Fire Troubleshooting Diagnostics and Problem SolvingDisposal of Ashes Maintenance and Servicing the FireplaceChimney Inspection/Cleaning Firebox RefractoryClean Maintenance Task ListWhen cleaning glass door Chimney FireFireplace Dimensions Reference MaterialsFireplace Components DescriptionChimney Components Catalog #Assembled Diameter 17 in./432 mm Height 24 in./610 mm 15-3/4 400 mm Woodburning Termination Cap 635 x 635 mm 584 x 584 mm 737 x 737 mmD. Service Parts MONTANA-36, MONTANA-36HService Parts MONTANA-42, MONTANA-42HThis page intentionally left blank This page intentionally left blank Warranty Coverage Limited Warranty This warranty is void ifRO N a CO ISD D